scholarly journals Variation in PCR Efficiencies between Quantification Standards and Clinical Specimens using Different Real-Time Quantitative PCR Interpretation Methods

The analysis of the Ct and standard curve produced by real-time polymerase chain reaction (PCR) is a well-established method for the quantification of nucleic acids. However, this method assumes that the PCR efficiency between the unknown specimen and standard is equal, resulting in the possibility of significant inaccuracies due to the presence of inhibitory agents in the unknown specimen. Although numerous methods have been proposed to correct this issue, the understanding of the differences in PCR efficiencies in clinical samples is limited. In this study, 1185 cytomegalovirus (CMV) DNA real-time PCR test results from 106 batches were analyzed. The PCR efficiencies were calculated using the cpD2, maxE, Cy0, maxRatio and window-of-linearity (WoL) methods. The concentrations were calculated using the cpD2, Cy0, maxRatio, WoL, and take off point (TOP) methods. The coefficient of variation (CV) in the efficiency of the quantification standards was less than 5% in all methods. Positive samples with high quantification values demonstrated lower PCR efficiency compared to the quantification standards. This suggests possible inaccuracies in quantification using quantification standards in clinical samples.

2007 ◽  
Vol 4 (1) ◽  
pp. 15-19 ◽  
Author(s):  
Chen Si ◽  
Huang Kun-Lun ◽  
Xu Wen-Tao ◽  
Li Yuan ◽  
Luo Yun-Bo

AbstractA rapid and accurate real-time quantitative polymerase chain reaction (real-time PCR) method with SYBR Green I was established for detectingEscherichia coliO157:H7. A pair of primers were designed to amplify theeaegene. The dissociation curves showed that the amplification product was very specific. The optimal conditions and standard curve were established. The result indicated that real-time PCR was 1000 times more sensitive than ordinary PCR.


2020 ◽  
Vol 17 (1) ◽  
Author(s):  
Yang Zhang ◽  
Chunyang Dai ◽  
Huiyan Wang ◽  
Yong Gao ◽  
Tuantuan Li ◽  
...  

Abstract Background Coronavirus disease 2019 (COVID-19), caused by SARS-CoV-2, is posing a serious threat to global public health. Reverse transcriptase real-time quantitative polymerase chain reaction (qRT-PCR) is widely used as the gold standard for clinical detection of SARS-CoV-2. Due to technical limitations, the reported positive rates of qRT-PCR assay of throat swab samples vary from 30 to 60%. Therefore, the evaluation of alternative strategies to overcome the limitations of qRT-PCR is required. A previous study reported that one-step nested (OSN)-qRT-PCR revealed better suitability for detecting SARS-CoV-2. However, information on the analytical performance of OSN-qRT-PCR is insufficient. Method In this study, we aimed to analyze OSN-qRT-PCR by comparing it with droplet digital PCR (ddPCR) and qRT-PCR by using a dilution series of SARS-CoV-2 pseudoviral RNA and a quality assessment panel. The clinical performance of OSN-qRT-PCR was also validated and compared with ddPCR and qRT-PCR using specimens from COVID-19 patients. Result The limit of detection (copies/ml) of qRT-PCR, ddPCR, and OSN-qRT-PCR were 520.1 (95% CI: 363.23–1145.69) for ORF1ab and 528.1 (95% CI: 347.7–1248.7) for N, 401.8 (95% CI: 284.8–938.3) for ORF1ab and 336.8 (95% CI: 244.6–792.5) for N, and 194.74 (95% CI: 139.7–430.9) for ORF1ab and 189.1 (95% CI: 130.9–433.9) for N, respectively. Of the 34 clinical samples from COVID-19 patients, the positive rates of OSN-qRT-PCR, ddPCR, and qRT-PCR were 82.35% (28/34), 67.65% (23/34), and 58.82% (20/34), respectively. Conclusion In conclusion, the highly sensitive and specific OSN-qRT-PCR assay is superior to ddPCR and qRT-PCR assays, showing great potential as a technique for detection of SARS-CoV-2 in patients with low viral loads.


2010 ◽  
Vol 134 (3) ◽  
pp. 444-448 ◽  
Author(s):  
Zhengming Gu ◽  
Jianmin Pan ◽  
Matthew J. Bankowski ◽  
Randall T. Hayden

Abstract Context.—BK virus infections among immunocompromised patients are associated with disease of the kidney or urinary bladder. High viral loads, determined by quantitative polymerase chain reaction (PCR), have been correlated with clinical disease. Objective.—To develop and evaluate a novel method for real-time PCR detection and quantification of BK virus using labeled primers. Design.—Patient specimens (n = 54) included 17 plasma, 12 whole blood, and 25 urine samples. DNA was extracted using the MagNA Pure LC Total Nucleic Acid Isolation Kit (Roche Applied Science, Indianapolis, Indiana); sample eluate was PCR-amplified using the labeled primer PCR method. Results were compared with those of a user-developed quantitative real-time PCR method (fluorescence resonance energy transfer probe hybridization). Results.—Labeled primer PCR detected less than 10 copies per reaction and showed quantitative linearity from 101 to 107 copies per reaction. Analytical specificity of labeled primer PCR was 100%. With clinical samples, labeled primer PCR demonstrated a trend toward improved sensitivity compared with the reference method. Quantitative assay comparison showed an R2 value of 0.96 between the 2 assays. Conclusions.—Real-time PCR using labeled primers is highly sensitive and specific for the quantitative detection of BK virus from a variety of clinical specimens. These data demonstrate the applicability of labeled primer PCR for quantitative viral detection and offer a simplified method that removes the need for separate oligonucleotide probes.


2013 ◽  
Vol 62 (7) ◽  
pp. 1081-1085 ◽  
Author(s):  
Maria Carla Liberto ◽  
Giovanni Matera ◽  
Angelo G. Lamberti ◽  
Angela Quirino ◽  
Giorgio S. Barreca ◽  
...  

Systemic Bartonella henselae infections are unusual in immunocompetent adults. However, here we report one such case of bartonellosis in a 34-year-old patient, who presented with fever and multinodular splenomegaly. We also describe a novel method of identifying Bartonella henselae by real-time quantitative polymerase chain reaction and sequencing of amplified products. This could prevent splenic bartonellosis being mistaken for lymphoma and thereby avert unnecessary splenectomy.


Author(s):  
Fabiola Mancini ◽  
Fabrizio Barbanti ◽  
Maria Scaturro ◽  
Stefano Fontana ◽  
Angela Di Martino ◽  
...  

Abstract Background Pandemic coronavirus disease 2019 (COVID-19) disease represents a challenge for healthcare structures. The molecular confirmation of samples from infected individuals is crucial and therefore guides public health decision making. Clusters and possibly increased diffuse transmission could occur in the context of the next influenza season. For this reason, a diagnostic test able to discriminate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from influenza viruses is urgently needed. Methods A multiplex real-time reverse-transcription polymerase chain reaction (PCR) assay was assessed using 1 laboratory protocol with different real-time PCR instruments. Overall, 1000 clinical samples (600 from samples SARS-CoV-2–infected patients, 200 samples from influenza-infected patients, and 200 negative samples) were analyzed. Results The assay developed was able to detect and discriminate each virus target and to intercept coinfections. The limit of quantification of each assay ranged between 5 and 10 genomic copy numbers, with a cutoff value of 37.7 and 37.8 for influenza and SARS-CoV-2 viruses, respectively. Only 2 influenza coinfections were detected in COVID-19 samples. Conclusions This study suggests that multiplex assay is a rapid, valid, and accurate method for the detection of SARS-CoV-2 and influenza viruses in clinical samples. The test may be an important diagnostic tool for both diagnostic and surveillance purposes during the seasonal influenza activity period.


2014 ◽  
Vol 25 (4) ◽  
pp. 217-221 ◽  
Author(s):  
Mohammad Rubayet Hasan ◽  
Rusung Tan ◽  
Ghada N Al-Rawahi ◽  
Eva Thomas ◽  
Peter Tilley

BACKGROUND:Bordetella pertussisinfections continue to be a major public health challenge in Canada. Polymerase chain reaction (PCR) assays to detectB pertussisare typically based on the multicopy insertion sequence IS481, which offers high sensitivity but lacks species specificity.METHODS: A novelB pertussisreal-time PCR assay based on the porin gene was tested in parallel with several previously published assays that target genes such as IS481,ptx-promoter, pertactin and a putative thialase. The assays were evaluated using a reference panel of common respiratory bacteria including differentBordetellaspecies and 107 clinical nasopharyngeal specimens. Discrepant results were confirmed by sequencing the PCR products.RESULTS: Analytical sensitivity was highest for the assay targeting the IS481element; however, the assay lacked specificity forB pertussisin the reference panel and in the clinical samples. False-positive results were also observed with assays targeting theptx-promoter and pertactin genes. A PCR assay based on the thialase gene was highly specific but failed to detect all reference strains ofB pertussis. However, a novel assay targeting the porin gene demonstrated high specificity forB pertussisboth in the reference panel and in clinical samples and, based on sequence-confirmed results, correctly predicted allB pertussis-positive cases in clinical samples. According to Probit regression analysis, the 95% detection limit of the new assay was 4 colony forming units/reaction.CONCLUSION: A novel porin assay forB pertussisdemonstrated superior performance and may be useful for improved molecular detection ofB pertussisin clinical specimens.


Critical Care ◽  
2010 ◽  
Vol 14 (4) ◽  
pp. R159 ◽  
Author(s):  
Katsunori Yanagihara ◽  
Yuko Kitagawa ◽  
Masao Tomonaga ◽  
Kunihiro Tsukasaki ◽  
Shigeru Kohno ◽  
...  

2021 ◽  
Author(s):  
Emmanuel Oladipo Babafemi

Abstract Background: COVID-19 has spread globally since its discovery in Hubei province, China in December 2019 and became pandemic in 2020. COVID-19 is a new betacoronavirus and a variant of severe acute respiratory syndrome coronavirus 2 (SARA- CoV-2). Rapid, accurate and reliable diagnosis of COVID-19 will prevent the spread and allow for appropriate management. The main objective of this systematic review is to identify, appraise and summarise the published evidence on the diagnostic performance and effectiveness of SARS-CoV-2 virus in the diagnosis of current or previous COVID-19 using real-time polymerase chain reaction (RT-PCR) assay in low-and middle-income countries (LMICs). Methods: We will search MEDLINE/PubMed, EMBASE, BIOSIS, LILACS, Cochrane Infectious Diseases Group Specialised Register (CIDG SR), Global Health, and CINAHL for published studies for the diagnosis of COVID-19 using real-time polymerase chain reaction assay in LMICs There will be no restriction regarding the language, date of publication, and publication status. We will include retrospective, cross-sectional and cohort observational studies will be included in the review. Selection of studies, data extraction and management, assessment of risk of bias, and quality of evidence will be performed by two independent reviewers (EB and BC). A third researcher (GM) will be consulted in case of discrepancies. Depending on the availability and quality of the data, a meta-analysis will be performed. Otherwise, findings will be qualitatively reported. Discussion: To our knowledge, this is the first systematic review and meta-analysis to assess the uptake of RT-PCR assay for SARS-CoV-2 detection from clinical samples in human in LMICs. This review will make available evidence on the uptake, accuracy, approach, and interpretation of results of this assay in the context of COVID-19 diagnosis which will meet an urgent need, considering the diagnostic challenges of RT-PCR assay for COVID-19 diagnosis in humans. Systematic review registration: PROSPERO CRD42021271894


Sign in / Sign up

Export Citation Format