Recovering Human 3D Model from Monocular 2d Imaged for Detecting Postures Deformilities

Author(s):  
Mrinal Walia ◽  
Raghavendra . ◽  
Raihan Iqbal ◽  
Ranjith T. R ◽  
Deepak G ◽  
...  
Keyword(s):  
2016 ◽  
Vol 54 (12) ◽  
pp. 1343-1404
Author(s):  
LS Spitzhorn ◽  
MA Kawala ◽  
J Adjaye
Keyword(s):  

2020 ◽  
Vol 14 (3) ◽  
pp. 7296-7308
Author(s):  
Siti Nur Humaira Mazlan ◽  
Aini Zuhra Abdul Kadir ◽  
N. H. A. Ngadiman ◽  
M.R. Alkahari

Fused deposition modelling (FDM) is a process of joining materials based on material entrusion technique to produce objects from 3D model using layer-by-layer technique as opposed to subtractive manufacturing. However, many challenges arise in the FDM-printed part such as warping, first layer problem and elephant food that was led to an error in dimensional accuracy of the printed parts especially for the overhanging parts. Hence, in order to investigate the manufacturability of the FDM printed part, various geometrical and manufacturing features were developed using the benchmarking artifacts. Therefore, in this study, new benchmarking artifacts containing multiple overhang lengths were proposed. After the benchmarking artifacts were developed, each of the features were inspected using 3D laser scanner to measure the dimensional accuracy and tolerances. Based on 3D scanned parts, 80% of the fabricated parts were fabricated within ±0.5 mm of dimensional accuracy as compared with the CAD data. In addition, the multiple overhang lengths were also successfully fabricated with a very significant of filament sagging observed.


2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Magdalena Cuman ◽  
Giuseppe Santoro ◽  
Katia Capellini ◽  
Emanuele Gasparotti ◽  
Alessandra Pizzuto ◽  
...  

2012 ◽  
Vol 17 (4) ◽  
pp. 179-190
Author(s):  
Kacper Pluta ◽  
Marcin Janaszewski ◽  
Michał Postolski

Abstract The article presents new conception of 3D model of human bronchial tubes, which represents bronchial tubes extracted from CT images of the chest. The new algorithm which generates new model is an extension of the algorithm (basic algorithm) proposed by Hiroko Kitaoka, Ryuji Takaki and Bela Suki. The basic model has been extended by geometric deformations of branches and noise which occur in bronchial trees extracted from CT images. The article presents comparison of results obtained with the use of the new algorithm and the basic one. Moreover, the discussion of usefulness of generated new models for testing of algorithms for quantitative analysis of bronchial tubes based on CT images is also included.


2007 ◽  
Vol 30 (4) ◽  
pp. 77
Author(s):  
Derek Cool ◽  
Shi Sherebrin ◽  
Jonathan Izawa ◽  
Joseph Chin ◽  
Aaron Fenster

Introduction: Transrectal ultrasound (TRUS) prostate biopsy (Bx) is currently confined to 2D information to both target and record 3D Bx locations. Accurate placement of Bx needles cannot be verified without 3D information, and recording Bx sites in 2D does not provide sufficient information to accurately guide the high incidence of repeat Bx. We have designed a 3D TRUS prostate Bx system that augments the current 2D TRUS system and provides tools for biopsy-planning, needle guidance, and recording of the biopsy core locations entirely in 3D. Methods: Our Bx system displays a 3D model of the patient’s prostate, which is generated intra-procedure from a collection of 2D TRUS images, representative of the particular prostate shape. Bx targets are selected, needle guidance is facilitated, and 3D Bx sites are recorded within the 3D context of the prostate model. The complete 3D Bx system was validated, in vitro, by performing standard ten-core Bx on anatomical phantoms of two patient’s prostates. The accuracy of the needle-guidance, Bx location recording, and 3D model volume and surface topology were validated against a CT gold standard. Results: The Bx system successfully reconstructed the 3D patient prostate models with a mean volume error of 3.2 ± 7.6%. Using the 3D system, needles were accurately guided to the pre-determined targets with a mean error of 2.26 ± 1.03 mm and the 3D locations of the Bx cores were accurately recorded with a mean distance error of 1.47 ± 0.79 mm. Conclusion: We have successfully developed a 3D TRUS prostate biopsy system and validated the system in vitro. A pilot study has been initiated to apply the system clinically.


Sign in / Sign up

Export Citation Format

Share Document