scholarly journals Disinfection efficacy studies on three different disinfection methods in health care facilities by ATP method

Author(s):  
Harry Zhuang ◽  
BCIT School of Health Sciences, Environmental Health ◽  
Helen Heacock ◽  
Fred Shaw

  Objectives: Nosocomial infection has always been a significant topic in the field of public health. The disinfection procedures involved in health care facilities are extremely important to prevent potential transmission of diseases. Therefore, this study was performed to compare the disinfection efficacy between three different disinfection methods (Accel wipes, Hubscrub industrial washer, and Steam vapor) on three pieces of non-critical medical equipment: wheelchairs, mattresses and bath chairs. Methods: The method used to evaluate the disinfection efficacy compared the reduction of contaminants count in the relative light unit using ATP monitoring methods. 30 samples of each of the three types of medical equipment were swabbed pre-disinfection and post-disinfection using the three disinfection methods. The recorded reduction number was then converted using log transformation. Statistical analysis was conducted using NCSS to assess differences between the disinfection methods. Results: The mean log-reduction of disinfection for Accel wipes, Hubscrub, and steam vapor were 1.067, 1.490, and 1.485 respectively. Steam vapor and Hubscrub displayed statistically significantly better disinfection efficacy compared to Accel wipes in terms of log reduction (overall p=0.000002). Conclusion: Hubscrub and steam vapor are better disinfectants compared to Accel wipes in terms of mean log reduction values; however, all three disinfection methods demonstrated effectiveness when cleaning and disinfecting non-critical medical equipment. For critical medical equipment, steam vapor and Hubscrub industrial washing are effective while Accel wipes do not meet the standards of high-level disinfection. As a result, combination usages of all three disinfection methods are recommended at health care facilities based on the categories of the medical equipment.  

2021 ◽  
Author(s):  
Andreas van Arkel ◽  
Ina Willemsen ◽  
Jan Kluytmans

Abstract Background:The objective of this study was to determine the correlation between adenosine triphosphate (ATP) measurements and microbial contamination using a standardized method. Methods: ATP measurements and aerobic colony counts (ACC’s) were conducted on 10 pre-defined fomites in a hospital and nursing home setting. Per fomite two ATP measurements and two agar plate measurements were conducted, each measurement was conducted on a 25 cm2 surface. Both measurements were compared and analyzed for correlation. Results: In total 200 paired measurements were conducted, 200 ATP measurements and 200 ACC’s. The mean of all ATP measurements tested on the same surface was calculated, as was for all 200 ACC’s. There was a strong correlation between the mean of two ATP measurements on two different sites on the same fomite (R=0.800, p<0.001) as well as between two ACC measurements on the same fomite (R=0.667, p<0.001). A much weaker correlation was found between RLU values and ACC’s (R=0.244, p<0.001). Conclusions: Reproducibility of ATP measurements and ACC’s on the same fomite was good. However, the correlation between RLU values and ACC’s on hospital surfaces was much lower. This may be explained by the wide variety of biological material that is measured with ATP, of which the bacterial load is only one of many components. ATP measurement can be used to give a quantifiable outcome for the rating of cleanliness in health care facilities, however the results cannot be translated into the level of microbial contamination.


Author(s):  
Aleksandra Rosiek-Kryszewska ◽  
Anna Rosiek

This chapter discusses the leadership features that support the creation of an innovative culture of the organization, with particular emphasis on the attributes that are essential to building a competitive advantage in the medical services market. According to the concept of new management, managers are the initiators of change and development within the healthcare facility where they work. They require professionalism and a high level of competence which allows them to create and implement creative management solutions. Thus, the influence of management and the role of the leader in building competitive health care units is undisputed. Due to the specific nature of health care facilities, the ability to build trust, as well as the clear and precise communication of plans and visions, is gaining importance, in addition to knowledge and experience.


2006 ◽  
Vol 25 (5) ◽  
pp. 261-266 ◽  
Author(s):  
M B Forrester

Concerns have been raised about the safety of celecoxib. This study described the pattern of exposures involving only celecoxib (isolated exposures) reported to Texas poison control centers from 1999 to 2004. The mean dose was 701 mg. The patient age distribution was 5 / 5 years (48%), 6 / 19 years (8%), and 20 years (44%). In 78% of cases, exposure was unintentional. Of the exposures, 74% were managed outside of health care facilities. The final medical outcome was classified as no effect for 82% of the cases, and minor effects for 12% of the cases. Adverse clinical effects were listed for 5% of the patients, the most frequently reported being rash (3%), drowsiness (3%), pruritis (2%), and vomiting (2%). The most frequently listed treatment was decontamination by dilution (43%) or food (32%). The majority of isolated celecoxib exposures could be managed outside of health care facilities, and the outcome was generally favorable.


2021 ◽  
Vol 74 (5) ◽  
pp. 1250-1255
Author(s):  
Oleg М. Reznik ◽  
Olha S. Bondarenko ◽  
Maryna S. Utkina ◽  
Nadiia S. Horobets

The aim: Characteristic of corruptive incomings laundering in the medical sphere and research of components for counteraction to this phenomenon. Materials and methods: Some methods were used to ensure the completeness and complexity of scientific research: dialectical, formal, legal, epistemological, and systemstructural methods. Conclusions: It was concluded that corruptive incomings laundering in the medical sphere is becoming commonplace. New ways, means, and schemes for the commission of this crime are appearing. The authors analyze the main methods for corruptive incomings laundering in the medical sphere: during the purchase of medicines and medical equipment, during the procurements of medical preparations and medical equipment, building restoration and renovation, where health care facilities are located, price-fixing and gifting of chief medical officers. A comprehensive system of organizational, legal, and economic measures must be formed that will provide effective counteraction to the corruptive incomings laundering in the medical sphere.


2019 ◽  
Vol 12 (2) ◽  
pp. 55-63
Author(s):  
Jarmmaree Sornboot ◽  
Wichai Aekplakorn ◽  
Pongrama Ramasoota ◽  
Surat Bualert ◽  
Somying Tumwasorn ◽  
...  

AbstractBackgroundLong-term surveillance of airborne bioaerosols in health care facilities is required to protect the health of patients and health care workers. Feasible methods to measure airborne bioaerosol concentrations and determine associated environmental factors may help to avoid nosocomial tuberculosis (TB).ObjectivesTo describe the concentrations and size of airborne bioaerosols and to identify the potential contributors to indoor airborne bioaerosols in TB high-risk areas in health care facilities.MethodsWe conducted a cross-sectional study in 7 large health care facilities located in Bangkok and nearby in central Thailand using a 6-stage Andersen cascade impactor to collect viable airborne bioaerosols that were quantified using culture techniques. Environmental parameters were determined using a tracer gas technique with an indoor air quality meter. Other potential factors were assessed using a questionnaire.ResultsThe mean indoor airborne bacterial and fungal concentrations were 596.1 and 521.2 colony-forming units (cfu)/m3, respectively, and the mean outdoor airborne bacterial and fungal concentrations were 496.5 and 650.1 cfu/m3, respectively. The majority of airborne bioaerosols were in respirable sizes. The indoor-to-outdoor ratios were 1.2 for bacteria and 0.8 for fungi. Air change rate was inversely correlated with indoor airborne bioaerosol concentrations, whereas emergency department central-type air conditioners and relative humidity were positively correlated with the indoor airborne bioaerosol concentrations (P < 0.05).ConclusionsHigh indoor bioaerosol concentrations found in the health care facilities suggest that it is imperative to improve the indoor air quality. Improved air change rate and avoiding use of central-type air-conditioning systems may reduce bioaerosol concentrations.


2021 ◽  
Vol 8 (3) ◽  
pp. 150-154
Author(s):  
Szymon Wit ◽  
Paweł Więch ◽  
Marta Kłęk ◽  
Marek Muster ◽  
Grzegorz Kucaba

Aim: The aim of the study was to evaluate the effectiveness of supraglottic airways management by paramedics using selected methods in simulated conditions. Material and methods: The study included a group of 115 professionally active paramedics working in various health care facilities in the Podkarpackie Province. Each subject was asked to open the airways using a laryngeal mask airway (LMA) and a disposable laryngeal tube (LT-D) in simulated conditions. The study assessed the effectiveness of the airway opening taking into account: average tidal volume of a single breath in ml, average minute tidal volume in ml, time of insertion in seconds, the need for a second attempt, pressure on incisors in N. The obtained results were statistically analysed, p<0.05 was considered statistically significant. The calculations were performed with the SPSS 20 software. results: The study showed that the time of inserting of LT-D is the same as the time of LMA (LT-D: 25.95s ± 7.89s vs. LMA: 24.78s ± 8.32s; p>0.05). The mean tidal volume of a single breath was significantly higher with the LMA com-pared to LT-D (LMA 633.24 ml vs. LT-D 579.68 ml, p<0.05). During LMA insertion, the pressure on incisors of 11.41N ± 6.22N was used, while in case of LT-D this pressure amounted to 13.15N ± 3.68N. Every fourth examined paramedic had problems with correct insertion of LT-D tube in accordance with the adopted algorithm. Conclusions: The supralottic LMA and LT-D tools seem to be an effective and safe alternative of the airway management in case of life emergency


Author(s):  
Andreas van Arkel ◽  
Ina Willemsen ◽  
Jan Kluytmans

Abstract Background The objective of this study was to determine the correlation between adenosine triphosphate (ATP) measurements and microbial contamination using a standardized method. Secondarily, analyzing reproducibility of ATP measurements and aerobic colony counts (ACC’s) on the same surface. Methods ATP measurements and ACC’s were conducted on 10 pre-defined fomites in a hospital and nursing home setting. Per fomite two ATP measurements and two agar plate measurements were conducted, each measurement was conducted on a 25 cm2 surface. Both measurements were compared and analyzed for correlation. Results In total 200 paired measurements were conducted, 200 ATP measurements and 200 ACC’s. The mean of all ATP measurements tested on the same surface was calculated, as was for all 200 ACC’s. There was a strong correlation between the mean of two ATP measurements on two different sites on the same fomite (R = 0.800, p < 0.001) as well as between two ACC measurements on the same fomite (R = 0.667, p < 0.001). A much weaker correlation was found between RLU values and ACC’s (R = 0.244, p < 0.001). Conclusions Reproducibility of ATP measurements and ACC’s on the same fomite was good. However, the correlation between RLU values and ACC’s on hospital surfaces was much lower. This may be explained by the wide variety of biological material that is measured with ATP, of which the bacterial load is only one of many components. ATP measurement can be used to give a quantifiable outcome for the rating of cleanliness in health care facilities, however the results cannot be translated into the level of microbial contamination.


Author(s):  
Ashwini Vishalakshi L. ◽  
Reddi Rani P.

Background: Maternal mortality in India is decreasing with the advances in health care facilities, increase in the number of hospital deliveries, improvement in the transport facilities etc. Present study aimed at to evaluate the causes for antepartum stillbirths.Methods: It is a retrospective study from the case records of the stillbirths that occurred from June 2015 to March 2018. All stillbirths between 28-41 weeks were studies. Stillbirths occurring in twin pregnancies were excluded. The total number of stillbirths that were studied was 102. Results: Most of the IUDs occurred between 28-37 weeks 82 (80.39%). The mean period of gestation at which the stillbirth occurred was 33.84±3.8 weeks. There was more number of male stillborns as compared to female stillborns. When the weight distribution of all stillbirths was compared with weight for gestational age 48 (47.5%) were <10% (SGA) and 46 (45.09%) of stillbirths weighed between 10th and 50th percentile Most of the IUDs were caused due to cord accidents, abruption and as a complication of hypertensive disorders of pregnancy.Conclusions: Stillbirths were higher in IUGR fetusus as compared to AGA fetuses. Hence in order to prevent stillbirth it would be mandatory to detect IUGR at an earlier stage and delivery should be planned if the fetus shows any features of compromise. Doppler studies can help in deciding the timing of delivery.


2021 ◽  
Author(s):  
Andreas van Arkel ◽  
Ina Willemsen ◽  
Jan Kluytmans

Abstract Background:The objective of this study was to determine the correlation between adenosine triphosphate (ATP) measurements and microbial contamination using a standardized method. Secondarily, analyzing reproducibility of ATP measurements and aerobic colony counts (ACC’s) on the same surface. Methods: ATP measurements and ACC’s were conducted on 10 pre-defined fomites in a hospital and nursing home setting. Per fomite two ATP measurements and two agar plate measurements were conducted, each measurement was conducted on a 25 cm2 surface. Both measurements were compared and analyzed for correlation.Results: In total 200 paired measurements were conducted, 200 ATP measurements and 200 ACC’s. The mean of all ATP measurements tested on the same surface was calculated, as was for all 200 ACC’s. There was a strong correlation between the mean of two ATP measurements on two different sites on the same fomite (R=0.800, p<0.001) as well as between two ACC measurements on the same fomite (R=0.667, p<0.001). A much weaker correlation was found between RLU values and ACC’s (R=0.244, p<0.001). Conclusions: Reproducibility of ATP measurements and ACC’s on the same fomite was good. However, the correlation between RLU values and ACC’s on hospital surfaces was much lower. This may be explained by the wide variety of biological material that is measured with ATP, of which the bacterial load is only one of many components. ATP measurement can be used to give a quantifiable outcome for the rating of cleanliness in health care facilities, however the results cannot be translated into the level of microbial contamination.


Sign in / Sign up

Export Citation Format

Share Document