DYNAMIC CHARACTERISTICS OF A SIX-STOREY STEEL BUILDING EXAMINED FROM STRONG MOTION AND AMBIENT VIBRATION DATA

Author(s):  
Toshihide Kashima ◽  
Hiroto Nakagawa
1973 ◽  
Vol 63 (3) ◽  
pp. 1025-1039
Author(s):  
Bruce M. Douglas ◽  
Thomas E. Trabert

abstract The coupled bending and torsional vibrations of a relatively symmetric 22-story reinforced concrete building in Reno, Nevada are studied. Analytical results are compared with observations obtained during the nuclear explosion FAULTLESS and to ambient vibration data. The fundamental periods of vibration observed during FAULTLESS were (TNS = 1.42, TEW = 1.81, TTORSION = 1.12 sec), and the calculated periods were (TNS = 2.14, TEW = 2.07, TTORSION = 1.90 sec). It was estimated that between 25 and 45 per cent of the total available nonstructural stiffness was required to explain the differences in the observed and calculated fundamental periods. Each floor diaphragm in the system was allowed three degrees of freedom-two translations and a rotation. It was found that coupled torsional motions can influence the response of structural elements near the periphery of the structure. Strong-motion structural response calculations comparing the simultaneous use of both components of horizontal ground motion to a single component analysis showed that the simultaneous application of both components of ground motion can significantly alter the response of lateral load-carrying elements. Differences of the order of 45 per cent were observed in the frames near the ends of the structure. Also, it was shown that the overall response of tall buildings is sensitive not only to the choice of input ground motion but also to the orientation of the structure with respect to the seismic waves.


2011 ◽  
Vol 105-107 ◽  
pp. 112-116
Author(s):  
Xiang Mei Yan

Based on the random vibration and system identification theory, the ambient vibration testing of two adjacent transmission towers were carried out, dynamic characteristics of the towers were obtained from ambient vibration data. The result shown that the suspended cables not only have mass effects, but have coupled stiffness effects applied to tower on transverse direction and longitudinal direction. At the same, testing value shows that the two adjacent towers have basically the same dynamic characteristics and damping ratio of the two transmission towers less than 0.01. Owing to the influence of conductors, frequency of the insulators is different to the towers at the two directions. It is disadvantage for wind-induced response of transmission line system under ambient loads.


2017 ◽  
Vol 2017 ◽  
pp. 1-20 ◽  
Author(s):  
Jun Ma ◽  
Shinji Nakata ◽  
Akihito Yoshida ◽  
Yukio Tamura

Full-scale tests on a one-story steel frame structure with a typical precast cladding system using ambient and free vibration methods are described in detail. The cladding system is primarily composed of ALC (Autoclaved Lightweight Concrete) external wall cladding panels, gypsum plasterboard interior linings, and window glazing systems. Ten test cases including the bare steel frame and the steel frame with addition of different parts of the precast cladding system are prepared for detailed investigations. The amplitude-dependent dynamic characteristics of the test cases including natural frequencies and damping ratios determined from the tests are presented. The effects of the ALC external wall cladding panels, the gypsum plasterboard interior linings, and the window glazing systems on the stiffness and structural damping of the steel frame are discussed in detail. The effect of the precast cladding systems on the amplitude dependency of the dynamic characteristics and the tendencies of the dynamic parameters with respect to the structural response amplitude are investigated over a wide range. Furthermore, results estimated from the ambient vibration method are compared with those from the free vibration tests to evaluate the feasibility of the ambient vibration method.


Author(s):  
Y. Rong ◽  
H. S. Tzou

Abstract The dynamic behavior of elastic joints strongly affect the dynamic performance of a jointed mechanical system. The dynamic contacts introduced by joint clearances create a system with nonlinear characteristics. Special effort needs to be made to study jointed mechanical systems. This paper presents an integrated joint dynamics system, which can be used to predict the dynamic characteristics of a newly designed structure, or to analyze an existing jointed structure. This joint dynamics system can also be applied as a real time monitoring and diagnosis system when it is connected with a vibration measuring device. The joint dynamics system includes: 1) a theoretical model of jointed structures, in which the joint clearance and joint friction effects are considered; 2) a stochastic simulator which is used to generate vibration data and evaluate system dynamic characteristics; 3) a diagnostic monitoring algorithm for vibration state detection; and 4) a forecasting vibration control scheme. The joint dynamics system is applied to the dynamic analysis of a truss-cell unit structure. The results presented in this paper show that the joint dynamics system is effective.


1983 ◽  
Vol 73 (6A) ◽  
pp. 1895-1902
Author(s):  
Gerard C. Pardoen

Abstract The ambient vibration test results conducted on the Imperial County Services Building prior to the 15 October 1979 Imperial Valley earthquake are summarized. These results are of significant interest because the Imperial County Services Building has been the source of many postearthquake investigations due to the fact that the 1979 earthquake represented the first time a building instrumented with strong motion recorders suffered and recorded the major structural failure.