scholarly journals Two-wavelength thermal–optical determination of light-absorbing carbon in atmospheric aerosols

2019 ◽  
Vol 12 (6) ◽  
pp. 3173-3182 ◽  
Author(s):  
Dario Massabò ◽  
Alessandro Altomari ◽  
Virginia Vernocchi ◽  
Paolo Prati

Abstract. Thermal–optical analysis is widely adopted for the quantitative determination of total (TC), organic (OC), and elemental (EC) carbon in atmospheric aerosol sampled by suitable filters. Nevertheless, the methodology suffers from several uncertainties and artifacts such as the well-known issue of charring affecting the OC–EC separation. In the standard approach, the effect of the possible presence of brown carbon, BrC, in the sample is neglected. BrC is a fraction of OC, usually produced by biomass burning with a thermic behavior intermediate between OC and EC. BrC is optically active: it shows an increasing absorbance when the wavelength moves to the blue–UV region of the electromagnetic spectrum. Definitively, the thermal–optical characterization of carbonaceous aerosol should be reconsidered to address the possible BrC content in the sample under analysis. We introduce here a modified Sunset Lab Inc. EC–OC analyzer. Starting from a standard commercial instrument, the unit has been modified at the physics department of the University of Genoa (Italy), making possible the alternative use of the standard laser diode at λ=635 nm and of a new laser diode at λ=405 nm. In this way, the optical transmittance through the sample can be monitored at both wavelengths. Since at shorter wavelengths the BrC absorbance is higher, a better sensitivity to this species is gained. The modified instrument also gives the possibility to quantify the BrC concentration in the sample at both wavelengths. The new unit has been thoroughly tested, with both artificial and real-world aerosol samples: the first experiment, in conjunction with the multi-wavelength absorbance analyzer (MWAA; Massabò et al., 2013, 2015), resulted in the first direct determination of the BrC mass absorption coefficient (MAC) at λ=405 nm: MAC =23±1 m2 g−1.

2019 ◽  
Author(s):  
Dario Massabò ◽  
Alessandro Altomari ◽  
Virginia Vernocchi ◽  
Paolo Prati

Abstract. Thermo-optical analysis is widely adopted for the quantitative determination of Total, TC, Organic, OC, and Elemental, EC, Carbon in atmospheric aerosol sampled by suitable filters. Nevertheless, the methodology suffers of several uncertainties and artefacts as the well-known issue of charring affecting the OC-EC separation. In the standard approach, the effect of the possible presence of Brown Carbon, BrC, in the sample is neglected. BrC is a fraction of OC, usually produced by biomass burning with a thermic behaviour intermediate between OC and EC. BrC is optically active: it shows an increasing absorbance when the wavelength moves to the blue/UV region of the electromagnetic spectrum. Definitively, the thermo-optical characterization of carbonaceous aerosol should be reconsidered to address the possible BrC content in the sample under analysis. We introduce here a modified Sunset Lab Inc. EC/OC Analyzer. Starting from a standard commercial set-up, the unit has been modified at the Physics Department of the University of Genoa (IT), making possible the alternative use of the standard laser diode at λ = 635 nm and of a new laser diode at λ = 405 nm. In this way, the optical transmittance through the sample can be monitored at both the wavelengths. Since at shorter wavelengths the BrC absorbance is higher, a better sensitivity to this species is gained. The modified set-up also gives the possibility to quantify the BrC concentration in the sample at both the wavelengths. The new unit has been thoroughly tested, with both artificial and real-world samples: the first experiment, in conjunction with the Multi Wavelength Absorbance Analyzer (MWAA, Massabò et al., 2013 and 2015), resulted in the first direct determination of the BrC Mass Absorption Coefficient (MAC) at λ = 405 nm: MAC = 23 ± 1 m2 g−1.


2015 ◽  
Vol 108 ◽  
pp. 1-12 ◽  
Author(s):  
D. Massabò ◽  
L. Caponi ◽  
V. Bernardoni ◽  
M.C. Bove ◽  
P. Brotto ◽  
...  

ACTA IMEKO ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 32
Author(s):  
Laura Guidorzi ◽  
Fulvio Fantino ◽  
Elisabetta Durisi ◽  
Marco Ferrero ◽  
Alessandro Re ◽  
...  

Classified as an absolute dating method, thermoluminescence (TL) is a well-established radiation-based technique for the age determination and authentication of ceramic materials. Specifically, this method allows the determination of the time elapsed since kiln firing (or later fire events) by evaluating the luminescent emission of ceramics under heating at high temperatures. This paper provides a comprehensive presentation of the TL laboratory developed over the last decade at the Physics Department of the University of Torino. The laboratory was set up in collaboration with TecnArt S.r.l. and is also currently operating within the cultural heritage network of the National Institute of Nuclear Physics (INFN-CHNet). More than 10 years of experience in the field has resulted in improvements in procedures, with the development of customised alpha- and beta-irradiation systems and the optimisation of sampling approaches and chemical pre-treatment. Thanks to TecnArt S.r.l., the laboratory has been employed for dating and authenticating hundreds of archaeological sites and artworks, some of which are discussed in this work and compared, when possible, with radiocarbon dating.


1961 ◽  
Vol 41 (4) ◽  
pp. 380-384 ◽  
Author(s):  
Arthur F. Dratz ◽  
James C. Coberly
Keyword(s):  

2002 ◽  
Vol 721 ◽  
Author(s):  
Monica Sorescu

AbstractWe propose a two-lattice method for direct determination of the recoilless fraction using a single room-temperature transmission Mössbauer measurement. The method is first demonstrated for the case of iron and metallic glass two-foil system and is next generalized for the case of physical mixtures of two powders. We further apply this method to determine the recoilless fraction of hematite and magnetite particles. Finally, we provide direct measurement of the recoilless fraction in nanohematite and nanomagnetite with an average particle size of 19 nm.


Sign in / Sign up

Export Citation Format

Share Document