scholarly journals Calibration and intercomparison of acetic acid measurements using proton-transfer-reaction mass spectrometry (PTR-MS)

2012 ◽  
Vol 5 (11) ◽  
pp. 2739-2750 ◽  
Author(s):  
K. B. Haase ◽  
W. C. Keene ◽  
A. A. P. Pszenny ◽  
H. R. Mayne ◽  
R. W. Talbot ◽  
...  

Abstract. Acetic acid is one of the most abundant organic acids in the ambient atmosphere, with maximum mixing ratios reaching into the tens of parts per billion by volume (ppbv) range. The identities and associated magnitudes of the major sources and sinks for acetic acid are poorly characterized, due in part to the limitations of available measurement techniques. This paper demonstrates that, when properly calibrated, proton-transfer-reaction mass spectrometry (PTR-MS) can be a valuable technique for fast response, accurate quantification of acetic acid in ambient air. Three different PTR-MS configurations were calibrated at low ppbv mixing ratios using permeation tubes, which yielded calibration factors between 7.0 and 10.9 normalized counts per second per ppbv (ncps ppbv−1) at a drift tube field strength of 132 Townsend (Td). Detection limits ranged from 0.06 to 0.32 ppbv with dwell times of 5 s. These calibration factors showed negligible humidity dependence. Acetic acid was measured with PTR-MS on Appledore B Island, ME, during the International Consortium for Atmospheric Research on Transport and Transformation (ICARTT) campaign and validated based on acetic acid measured in parallel using tandem mist chambers coupled with ion chromatography (MC/IC). Mixing ratios ranged from a minimum of 0.075 ± 0.004 ppbv to 3.555 ± 0.171 ppbv, with a median mixing ratio of 0.530 ± 0.025 ppbv. An orthogonal least squares linear regression of paired data yielded a slope of 1.14 ± 0.06 (2σ), an intercept of 0.049 ± 0.020 (2σ) ppbv, and an R2 of 0.78.

2012 ◽  
Vol 5 (4) ◽  
pp. 4635-4665 ◽  
Author(s):  
K. B. Haase ◽  
W. C. Keene ◽  
A. A. P. Pszenny ◽  
H. R. Mayne ◽  
R. W. Talbot ◽  
...  

Abstract. Acetic acid is one of the most abundant organic acids in the ambient atmosphere, with maximum mixing ratios reaching into the tens of parts per billion by volume (ppbv) range. The identities and associated magnitudes of the major sources and sinks for acetic acid are poorly characterized, due in part to the limitation in available measurement techniques. This paper demonstrates that Proton Transfer Reaction Mass Spectrometry (PTR-MS) can reliably quantify acetic acid vapor in ambient air. Three different PTR-MS configurations were calibrated at low ppbv mixing ratios using permeation tubes, which yielded calibration factors between 7.0 and 10.9 normalized counts per second per ppbv (ncps ppbv−1) at a drift tube field strength of 132 townsend (Td). Detection limits ranged from 0.06 to 0.32 ppbv with dwell times of 5 s. These calibration factors showed negligible humidity dependence. Using the experimentally determined calibration factors, PTR-MS measurements of acetic acid during the International Consortium for Atmospheric Research on Transport and Transformation (ICARTT) campaign were validated against results obtained using Mist Chambers coupled with Ion Chromatography (MC/IC). An orthogonal least squares linear regression of paired data yielded a slope of 1.14 ± 0.06 (2σ), an intercept of 0.049 ± 20 (2σ) ppbv, and an R2 of 0.78. The median mixing ratio of acetic acid on Appledore Island, ME during the ICARTT campaign was 0.530 ± 0.025 ppbv with a minimum of 0.075 ± 0.004 ppbv, and a maximum of 3.555 ± 0.171 ppbv.


2010 ◽  
Vol 3 (4) ◽  
pp. 1055-1062 ◽  
Author(s):  
A. Vlasenko ◽  
A .M. Macdonald ◽  
S. J. Sjostedt ◽  
J. P. D. Abbatt

Abstract. Formaldehyde measurements can provide useful information about photochemical activity in ambient air, given that HCHO is formed via numerous oxidation processes. Proton transfer reaction mass spectrometry (PTR-MS) is an online technique that allows measurement of VOCs at the sub-ppbv level with good time resolution. PTR-MS quantification of HCHO is hampered by the humidity dependence of the instrument sensitivity, with higher humidity leading to loss of PTR-MS signal. In this study we present an analytical, first principles approach to correct the PTR-MS HCHO signal according to the concentration of water vapor in sampled air. The results of the correction are validated by comparison of the PTR-MS results to those from a Hantzsch fluorescence monitor which does not have the same humidity dependence. Results are presented for an intercomparison made during a field campaign in rural Ontario at Environment Canada's Centre for Atmospheric Research Experiments.


2010 ◽  
Vol 3 (2) ◽  
pp. 965-988 ◽  
Author(s):  
A. Vlasenko ◽  
A. M. Macdonald ◽  
S. J. Sjostedt ◽  
J. P. D. Abbatt

Abstract. Formaldehyde measurements can provide useful information about photochemical activity in ambient air, given that HCHO is formed via numerous oxidation processes. Proton transfer reaction mass spectrometry (PTR-MS) is an online technique that allows measurement of VOCs at the sub-ppbv level with good time resolution. PTR-MS quantification of HCHO is hampered by the humidity dependence of the instrument sensitivity, with higher humidity leading to loss of PTR-MS signal. In this study we present an analytical, first principles approach to correct the PTR-MS HCHO signal according to the concentration of water vapor in sampled air. The results of the correction are validated by comparison of the PTR-MS results to those from a Hantzsch fluorescence monitor which does not have the same humidity dependence. Results are presented for an intercomparison made during a field campaign in rural Ontario at Environment Canada's Centre for Atmospheric Research Experiments.


Sign in / Sign up

Export Citation Format

Share Document