breath analysis
Recently Published Documents


TOTAL DOCUMENTS

751
(FIVE YEARS 197)

H-INDEX

57
(FIVE YEARS 11)

Author(s):  
Shrushti S. Shetty ◽  
A. Jayarama ◽  
Shashidhara Bhat ◽  
Satyanarayan ◽  
Iddya Karunasagar ◽  
...  

Chemosensors ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. 356
Author(s):  
Lorena Di Zazzo ◽  
Gabriele Magna ◽  
Martina Lucentini ◽  
Manuela Stefanelli ◽  
Roberto Paolesse ◽  
...  

The correlation between breath volatilome and health is prompting a growing interest in the development of sensors optimized for breath analysis. On the other hand, the outbreak of COVID-19 evidenced that breath is a vehicle of infection; thus, the introduction of low-cost and disposable devices is becoming urgent for a clinical implementation of breath analysis. In this paper, a proof of concept about the functionalization of face masks is provided. Porphyrin-based sensors are among the most performant devices for breath analysis, but since porphyrins are scarcely conductive, they make use of costly and bulky mass or optical transducers. To overcome this drawback, we introduce here a hybrid material made of conducting polymer and porphyrins. The resulting material can be easily deposited on the internal surface of standard FFP face masks producing resistive sensors that retain the chemical sensitivity of porphyrins implementing their combinatorial selectivity for the identification of volatile compounds and the classification of complex samples. The sensitivity of sensors has been tested with respect to a set of seven volatile compounds representative of diverse chemical families. Sensors react to all compounds but with a different sensitivity pattern. Functionalized face masks have been tested in a proof-of-concept test aimed at identifying changes of breath due to the ingestion of beverages (coffee and wine) and solid food (banana- and mint-flavored candies). Results indicate that sensors can detect volatile compounds against the background of normal breath VOCs, suggesting the possibility to embed sensors in face masks for extensive breath analysis


2021 ◽  
Author(s):  
Nidheesh V. R. ◽  
Aswini Kumar Mohapatra ◽  
Unnikrishnan V. K. ◽  
Rajeev Kumar Sinha ◽  
Vasudevan Baskaran Kartha ◽  
...  

Biosensors ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 476
Author(s):  
Kaushiki Dixit ◽  
Somayeh Fardindoost ◽  
Adithya Ravishankara ◽  
Nishat Tasnim ◽  
Mina Hoorfar

With the global population prevalence of diabetes surpassing 463 million cases in 2019 and diabetes leading to millions of deaths each year, there is a critical need for feasible, rapid, and non-invasive methodologies for continuous blood glucose monitoring in contrast to the current procedures that are either invasive, complicated, or expensive. Breath analysis is a viable methodology for non-invasive diabetes management owing to its potential for multiple disease diagnoses, the nominal requirement of sample processing, and immense sample accessibility; however, the development of functional commercial sensors is challenging due to the low concentration of volatile organic compounds (VOCs) present in exhaled breath and the confounding factors influencing the exhaled breath profile. Given the complexity of the topic and the skyrocketing spread of diabetes, a multifarious review of exhaled breath analysis for diabetes monitoring is essential to track the technological progress in the field and comprehend the obstacles in developing a breath analysis-based diabetes management system. In this review, we consolidate the relevance of exhaled breath analysis through a critical assessment of current technologies and recent advancements in sensing methods to address the shortcomings associated with blood glucose monitoring. We provide a detailed assessment of the intricacies involved in the development of non-invasive diabetes monitoring devices. In addition, we spotlight the need to consider breath biomarker clusters as opposed to standalone biomarkers for the clinical applicability of exhaled breath monitoring. We present potential VOC clusters suitable for diabetes management and highlight the recent buildout of breath sensing methodologies, focusing on novel sensing materials and transduction mechanisms. Finally, we portray a multifaceted comparison of exhaled breath analysis for diabetes monitoring and highlight remaining challenges on the path to realizing breath analysis as a non-invasive healthcare approach.


2021 ◽  
pp. 00493-2021
Author(s):  
M. Westhoff ◽  
M. Friedrich ◽  
J. I. Baumbach

The high sensitivity of methods, which are applied in breath analysis, entails a high risk of detecting analytes which do not derive from endogenous production. Consequentially, it appears useful to have knowledge about the composition of inhaled air and to include alveolar gradients into interpretation.The current study aimed to standardise sampling procedures in breath analysis, especially with multicapillary column ion-mobility spectrometry (MCC-IMS), by applying a simultaneous registration of inhaled air and exhaled breath.A “Double MCC-IMS” device, which for the first time allows simultaneous analysis of inhaled air and exhaled breath, was developed and tested in 18 healthy individuals. For this two BreathDiscoverys® (BDs) were coupled with each other.Measurements of inhaled air and exhaled breath in 18 healthy individuals (mean age 46±10.9 years; 9 men, 9 women) identified 35 different volatile organic compounds (VOCs) for further analysis. Not all out of these had positive alveolar gradients and could be regarded as endogenous VOCs; 16 VOCs had a positive alveolar gradient in mean, 19 VOCs a negative one. 12 VOCs were positive in more than 12 of the healthy subjects.For the first time in our understanding a method is described, which enables simultaneous measurement of inhaled air and exhaled breath. This facilitates the calculation of alveolar gradients and selection of endogenous VOCs for exhaled breath analysis. Only a part of VOCs in exhaled breath are truly endogenous VOCs. The observation of different and varying polarities of the alveolar gradients needs further analysis.


Author(s):  
Fabienne Decrue ◽  
Kapil Dev Singh ◽  
Amanda Gisler ◽  
Mo Awchi ◽  
Jiafa Zeng ◽  
...  

Author(s):  
Dahlia Salman ◽  
Wadah Ibrahim ◽  
Amisha Kanabar ◽  
Abigail Joyce ◽  
Bo Zhao ◽  
...  

Abstract The development of clinical breath-analysis is confounded by the variability of background volatile organic compounds (VOC). Reliable interpretation of clinical breath-analysis at individual, and cohort levels requires characterisation of clinical-VOC levels and exposures. Active-sampling with thermal-desorption/gas chromatography-mass spectrometry recorded and evaluated VOC concentrations in 245 samples of indoor air from three sites in a large NHS provider trust in the UK over 27 months. Data deconvolution, alignment and clustering isolated 7344 features attributable to VOC and described the variability (composition and concentration) of respirable clinical VOC. 328 VOC were observed in more than 5% of the samples and 68 VOC appeared in more than 30% of samples. Common VOC were associated with exogenous and endogenous sources and 17 VOC were identified as seasonal differentiators. The presence of metabolites from the anaesthetic sevoflurane, and putative-disease biomarkers in room air, indicated that exhaled VOC were a source of background-pollution in clinical breath-testing activity. With the exception of solvents, and PPE waxes, exhaled VOC concentrations above 3 µg m-3 are unlikely to arise from room air contamination, and in the absence of extensive survey-data, this level could be applied as a threshold for inclusion in studies, removing a potential environmental confounding-factor in developing breath-based diagnostics.


Author(s):  
Mustafa Abumeeiz ◽  
Lauren Elliott ◽  
Phillip Olla

Abstract Due to the COVID-19 pandemic, there is currently a need for accurate, rapid, and easy-to-administer diagnostic tools to help communities manage local outbreaks and assess the spread of disease. The use of Artificial Intelligence within the domain of breath analysis techniques has shown to have potential in diagnosing a variety of diseases such as cancer and lung disease by analyzing volatile organic compounds (VOCs) in exhaled breath. This combined with their rapid, easy-to-use, and non-invasive nature makes them a good candidate for use in diagnosing COVID-19 in large scale public health operations. However, there remains issues with their implementation when it comes to the infrastructure currently available to support their use on a broad scale. This includes issues of standardization, and whether or not a characteristic VOC pattern can be identified for COVID-19. Despite these difficulties, breathalysers offer potential to assist in pandemic responses and their use should be investigated.


Sign in / Sign up

Export Citation Format

Share Document