scholarly journals Devices for accurate placement of epidural Tuohy needle for Anaesthesia administration

2014 ◽  
Vol 5 (1) ◽  
pp. 1-6 ◽  
Author(s):  
N. Vaughan ◽  
V. N. Dubey ◽  
M. Y. K. Wee ◽  
R. Isaacs

Abstract. The aim of this project is to design two sterile devices for epidural needle insertion which can measure in real time (i) the depth of needle tip during insertion and (ii) interspinous pressure changes through a pressure measurement device as the epidural needle is advanced through the tissue layers. The length measurement device uses a small wireless camera with video processing computer algorithms which can detect and measure the moving needle. The pressure measurement device uses entirely sterile componenets including a pressure transducer to accurately measure syringe saline in mm Hg. The data from these two devices accurately describe a needle insertion allowing comparison or review of insertions. The data was then cross-referenced to pre-measured data from MRI or ultrasound scan to identify how ligemant thickness correlates to our measured depth and pressure data. The developed devices have been tested on a porcine specimen during insertions performed by experienced anaesthetists. We have obtained epidural pressures for each ligament and demonstrated functionality of our devices to measure pressure and depth of epidural needle during insertion. This has not previously been possible to monitor in real-time. The benefits of these devices are (i) to provide an alternative method to identify correct needle placement during the procedure on real patients. (ii) The data describing the speed, depth and pressure during insertion can be used to configure an epidural simulator, simulating the needle insertion procedure. (iii) Our pressure and depth data can be compared to pre-measured MRI and ultrasound to identify previously unknown links between epidural pressure and depth with BMI, obesity and body shapes.

Pain Medicine ◽  
2019 ◽  
Vol 20 (9) ◽  
pp. 1750-1755 ◽  
Author(s):  
Hesham Elsharkawy ◽  
Wael Saasouh ◽  
Rovnat Babazade ◽  
Loran Mounir Soliman ◽  
Jean-Louis Horn ◽  
...  

Abstract Objective The anatomical landmarks method is currently the most widely used technique for epidural needle insertion and is faced with multiple difficulties in certain patient populations. Real-time ultrasound guidance has been recently used to aid in epidural needle insertion, with promising results. Our aim was to test the feasibility, success rate, and satisfaction associated with a novel real-time ultrasound-guided lumbar epidural needle insertion in the transverse interlaminar view. Design Prospective descriptive trial on a novel approach. Setting Operating room and preoperative holding area at a tertiary care hospital. Subjects Adult patients presenting for elective open prostatectomy and planned for surgical epidural anesthesia. Methods Consented adult patients aged 30–80 years scheduled for open prostatectomy under epidural anesthesia were enrolled. Exclusion criteria included allergy to local anesthetics, infection at the needle insertion site, coagulopathy, and patient refusal. A curvilinear low-frequency (2–5 MHz) ultrasound probe and echogenic 17-G Tuohy needles were used by one of three attending anesthesiologists. Feasibility of epidural insertion was defined as a 90% success rate within 10 minutes. Results Twenty-two patients were enrolled into the trial, 14 (63.6%) of whom found the process to be satisfactory or very satisfactory. The median time to perform the block was around 4.5 minutes, with an estimated success rate of 95%. No complications related to the epidural block were observed over the 48 hours after the procedure. Conclusions We demonstrate the feasibility of a novel real-time ultrasound-guided epidural with transverse interlaminar view.


2016 ◽  
Vol 125 (4) ◽  
pp. 793-804 ◽  
Author(s):  
T. Anthony Anderson ◽  
Jeon Woong Kang ◽  
Tatyana Gubin ◽  
Ramachandra R. Dasari ◽  
Peter T. C. So

Abstract Background Neuraxial anesthesia and epidural steroid injection techniques require precise anatomical targeting to ensure successful and safe analgesia. Previous studies suggest that only some of the tissues encountered during these procedures can be identified by spectroscopic methods, and no previous study has investigated the use of Raman, diffuse reflectance, and fluorescence spectroscopies. The authors hypothesized that real-time needle-tip spectroscopy may aid epidural needle placement and tested the ability of spectroscopy to distinguish each of the tissues in the path of neuraxial needles. Methods For comparison of detection methods, the spectra of individual, dissected ex vivo paravertebral and neuraxial porcine tissues were collected using Raman spectroscopy (RS), diffuse reflectance spectroscopy, and fluorescence spectroscopy. Real-time spectral guidance was tested using a 2-mm inner-diameter fiber-optic probe-in-needle device. Raman spectra were collected during the needle’s passage through intact paravertebral and neuraxial porcine tissue and analyzed afterward. The RS tissue signatures were verified as mapping to individual tissue layers using histochemical staining and widefield microscopy. Results RS revealed a unique spectrum for all ex vivo paravertebral and neuraxial tissue layers; diffuse reflectance spectroscopy and fluorescence spectroscopy were not distinct for all tissues. Moreover, when accounting for the expected order of tissues, real-time Raman spectra recorded during needle insertion also permitted identification of each paravertebral and neuraxial porcine tissue. Conclusions This study demonstrates that RS can distinguish the tissues encountered during epidural needle insertion. This technology may prove useful during needle placement by providing evidence of its anatomical localization.


2002 ◽  
Author(s):  
Wei Liu ◽  
Zeying Chi ◽  
Wenjian Chen

Sign in / Sign up

Export Citation Format

Share Document