scholarly journals Comparison of force decay pattern in orthodontic elastomeric chains and NiTi closed coil springs, affected by five different mouthwashes: An in vitro Study

2021 ◽  
Vol 9 (1) ◽  
Author(s):  
Amir Hossein Mirhashemi ◽  
Niloofar Habibi Khameneh ◽  
Keyvan Shahpoorzadeh ◽  
Atefe Saffar Shahroudi

Background: The aim of this study was to compare the force decay pattern of elastomeric chains and NiTi coil springs which were exposed to five different commercially available mouthwashes.Methods: In this in vitro study, 60 pieces of elastomeric chain (EC) and 60 NiTi closed coil springs (CS) were divided into 6 groups. The specimens were exposed to one of these mouthwashes twice a day for 60 seconds:  Listerine, chlorhexidine, Orthokin, Persica, fluoride and artificial saliva as the control group. The elastomeric chains and NiTi springs were stretched so that they exert the initial force of 250 gr. Their force was measured on the 1, 7, 14 and 28 following days by means of a digital gauge.Results: Elastomeric chains and coil springs had force decrease over time, but EC' force reduction was greater with the highest reduction rate in the first week. However, in the CS group, the force decrease wasn't statistically significant in the first two weeks.  After 28 days in the control groups, 49.8% of the initial force was remained in ECs while the value was 93.3% for CSs. In comparison between mouthwashes, in EC groups, in all mouthwashes except Persica, the remained force was statistically less than control group.Conclusion: Force degradation of elastomeric chains could be exacerbated by use of mouthwashes. About coil springs, force decay was also observed. However, it was not statistically significant. Force reduction was detectable after four weeks of coil springs usage, but in EC groups, the greatest reduction was after the first week.  

2020 ◽  
Vol 14 (4) ◽  
pp. 244-249
Author(s):  
Amir Hossein Mirhashemi ◽  
Atefe Saffar Shahroudi ◽  
Keyvan Shahpoorzadeh ◽  
Niloofar Habibi Khameneh

Background. This study compared the force decay pattern of two different orthodontic active tiebacks (ATBs) exposed to five different commercially available mouth rinses. Methods. In this in vitro study, 90 transparent ATBs and 90 gray ATBs were divided into six groups; one was the control group, and the others were exposed to one of these mouth rinses twice a day for 60 seconds: Listerine, chlorhexidine, Orthokin, Persica, and fluoride. The initial force of each ATB was 250 g at a 24-mm extension. The force of ATBs was measured on days 1, 7, 14, and 28 using a digital gauge. Results. The highest percentage of force loss was observed between days 14 and 28 (P<0.05). At the end of the study, the Persica group exhibited the highest force degradation in both ATB types. In the transparent ATBs, it was followed by Orthokin, Listerine, fluoride, chlorhexidine, and control groups, respectively. In the gray ATBs, Orthokin, chlorhexidine, control, Listerine, and fluoride groups exhibited the highest force decay in descending order. In some groups, the differences between transparent and gray ATBs were significant. In the control group, the force of transparent ATB was significantly higher than gray ones on days 7 and 14 but not significantly after four weeks. Conclusion. ATBs’ force degradation could be exacerbated by the use of some mouth rinses. There were some differences between force relaxation patterns of transparent and gray ATBs. The data could be beneficial in choosing appropriate O-rings for making ATBs.


2007 ◽  
Vol 21 (1) ◽  
pp. 51-57 ◽  
Author(s):  
Ana Cristina Soares Santos ◽  
André Tortamano ◽  
Sandra Regina Frazatto Naccarato ◽  
Gladys Cristina Dominguez-Rodriguez ◽  
Julio Wilson Vigorito

This in vitro study was designed to compare the forces generated by commercially available elastomeric chains and NiTi closed coil springs, and to determine their force decay pattern. Forty elastomeric chains and forty NiTi closed coil springs were divided into 4 groups according to the following manufacturers: (1) Morelli®, (2) Abzil®, (3) TP Orthodontics® and (4) American Orthodontics®. The specimens were extended to twice their original length and stored in artificial saliva at 37°C. Initial force was measured by means of an Instron universal testing machine and then at 1, 4, 7, 14, 21, and 28 days. The results revealed that the elastomeric chains delivered a mean initial force of 347 g for Morelli®, 351 g for American Orthodontics®, 402 g for Abzil®, and 404 g for TP Orthodontics®. The NiTi closed coil springs generated a mean initial force of 196 g for American Orthodontics®, 208 g for TP Orthodontics®, 216 g for Abzil®, and 223 g for Morelli®. The mean percentage of force decay observed after 28 days for the elastomeric chains was 37.4% for TP Orthodontics®, 48.1% for American Orthodontics®, 65.4% for Morelli®, and 71.6% for Abzil®. After 28 days, the NiTi closed coil springs presented a mean percentage of force decay of 22.6% for American Orthodontics®, 29.8% for Abzil®, 30.6% for Morelli®, and 45.8% for TP Orthodontics®. At the end of the study, significant differences were observed between the elastomeric chains and the NiTi closed coil springs. The results indicated that the studied NiTi closed coil springs are more adequate for dental movement than the elastomeric chains.


2015 ◽  
Vol 13 (3) ◽  
pp. 287-301 ◽  
Author(s):  
Abdullah M. Aldrees ◽  
Sahal A. Al-Foraidi ◽  
Mohammed S. Murayshed ◽  
Khalid A. Almoammar

2018 ◽  
Vol 53 (6) ◽  
pp. 31-389
Author(s):  
Saeed Sallam ◽  
Ahmed Ramadan ◽  
Wallaa Elgamy

2019 ◽  
Vol 13 (4) ◽  
pp. 305-310
Author(s):  
Mina Biria ◽  
Sajedeh Namaei Ghasemi ◽  
Seyedeh Mahsa Sheikh-Al-Eslamian ◽  
Narges Panahandeh

Background. This in vitro study aimed to evaluate the microshear bond strength (μSBS), microhardness and morphological characteristics of primary enamel after treating with sodium fluoride (NaF) and acidulated phosphate fluoride (APF). Methods. Forty-eight primary canines were cut into mesial and distal sections and assigned to five groups randomly: group 1 (immersed in saliva as a control), group 2 (treated with NAF and immersed in saliva for 30 minutes), group 3 (treated with APF and immersed in saliva for 30 minutes), group 4 (treated with NAF and immersed in saliva for 10 days), and group 5 (treated with APF and immersed in saliva for 10 days). Composite resin (Filtek Z250) was bonded on the specimens (n=15) for measuring the μSBS. After storage in 37°C artificial saliva for 24 hours, µSBS and Vickers hardness tests (10 readings) were performed. The data were analyzed using one-way ANOVA and Kolmogorov-Smirnov, Levene’s and Tukey HSD tests (P<0.05). Morphological analysis of enamel and modes of failure were carried out under a scanning electron microscope (SEM) on two remaining specimens. Results. Significant differences in μSBS were only noted between groups 2 and 4 (P=0.024). Group 3 showed a significant decrease in hardness after storage in artificial saliva (P<0.001), with a significantly lower hardness than the other groups (P<0.001). The SEM observations showed irregular particles in groups 3 and 5; uniform, smooth and thin coats were seen in groups 2 and 4. Conclusion. Fluoride therapy with NaF and APF gels prior to restorative treatments had no adverse effects on the microshear bond strength.


PeerJ ◽  
2016 ◽  
Vol 4 ◽  
pp. e2458 ◽  
Author(s):  
Bruna Raquel Zancopé ◽  
Vanessa B. Dainezi ◽  
Marinês Nobre-dos-Santos ◽  
Sillas Duarte ◽  
Vanessa Pardi ◽  
...  

BackgroundA carbon dioxide (CO2) laser has been used to morphologically and chemically modify the dental enamel surface as well as to make it more resistant to demineralization. Despite a variety of experiments demonstrating the inhibitory effect of a CO2laser in reduce enamel demineralization, little is known about the effect of surface irradiated on bacterial growth. Thus, this in vitro study was preformed to evaluate the biofilm formation on enamel previously irradiated with a CO2laser (λ = 10.6 µM).MethodsFor this in vitro study, 96 specimens of bovine enamel were employed, which were divided into two groups (n = 48): 1) Control-non-irradiated surface and 2) Irradiated enamel surface. Biofilms were grown on the enamel specimens by one, three and five days under intermittent cariogenic condition in the irradiated and non-irradiated surface. In each assessment time, the biofilm were evaluated by dry weigh, counting the number of viable colonies and, in fifth day, were evaluated by polysaccharides analysis, quantitative real time Polymerase Chain Reaction (PCR) as well as by contact angle. In addition, the morphology of biofilms was characterized by fluorescence microscopy and field emission scanning electron microscopy (FESEM). Initially, the assumptions of equal variances and normal distribution of errors were conferred and the results are analyzed statistically by t-test and Mann Whitney test.ResultsThe mean of log CFU/mL obtained for the one-day biofilm evaluation showed that there is statistical difference between the experimental groups. When biofilms were exposed to the CO2laser, CFU/mL and CFU/dry weight in three day was reduced significantly compared with control group. The difference in the genes expression (Glucosyltransferases (gtfB) and Glucan-binding protein (gbpB)) and polysaccharides was not statically significant. Contact angle was increased relative to control when the surface was irradiated with the CO2laser. Similar morphology was also visible with both treatments; however, the irradiated group revealed evidence of melting and fusion in the specimens.ConclusionIn conclusion, CO2laser irradiation modifies the energy surface and disrupts the initial biofilm formation.


2013 ◽  
Vol 11 (1) ◽  
pp. 60-70 ◽  
Author(s):  
Abdelali Halimi ◽  
Mohamed-Faouzi Azeroual ◽  
Anas Doukkali ◽  
Khalid El Mabrouk ◽  
Fatima Zaoui

2017 ◽  
Vol 28 (2) ◽  
pp. 97-103
Author(s):  
Athraa A. Abass ◽  
Akram F. Alhuwaizi