scholarly journals Comparison of planar imaging with I-123 MIBG scintigraphy and SPECT-CT imaging for pheochromocytoma

Author(s):  
İlhan Tumar ◽  
◽  
Filiz Özülker
2021 ◽  
Vol 25 (1) ◽  
Author(s):  
Ross W. Stephens ◽  
Gregory D. Tredwell ◽  
Jessica L. Bell ◽  
Karen J. Knox ◽  
Lee A. Philip ◽  
...  

Abstract Background Understanding the regional vascular delivery of particles to tumour sites is a prerequisite for developing new diagnostic and therapeutic composites for treatment of oncology patients. We describe a novel imageable 67Ga-radiolabelled polymer composite that is biocompatible in an animal tumour model and can be used for preclinical imaging investigations of the transit of different sized particles through arterial networks of normal and tumour-bearing organs. Results Radiolabelling of polymer microspheres with 67Ga was achieved using a simple mix and wash method, with tannic acid as an immobilising agent. Final in vitro binding yields after autoclaving averaged 94.7%. In vivo stability of the composite was demonstrated in New Zealand white rabbits by intravenous administration, and intrahepatic artery instillations were made in normal and VX2 tumour implanted rabbit livers. Stability of radiolabel was sufficient for rabbit lung and liver imaging over at least 3 hours and 1 hour respectively, with lung retention of radiolabel over 91%, and retention in both normal and VX2 implanted livers of over 95%. SPECT-CT imaging of anaesthetised animals and planar imaging of excised livers showed visible accumulation of radiolabel in tumours. Importantly, microsphere administration and complete liver dispersal was more easily achieved with 8 μm diameter MS than with 30 μm MS, and the smaller microspheres provided more distinct and localised tumour imaging. Conclusion This method of producing 67Ga-radiolabelled polymer microspheres is suitable for SPECT-CT imaging of the regional vascular delivery of microspheres to tumour sites in animal models. Sharper distinction of model tumours from normal liver was obtained with smaller MS, and tumour resolution may be further improved by the use of 68Ga instead of 67Ga, to enable PET imaging.


2004 ◽  
Vol 171 (4S) ◽  
pp. 507-507 ◽  
Author(s):  
Sanoj P. Punnen ◽  
Massoom A. Haider ◽  
Fenella Moulding ◽  
Martin O'Malley ◽  
Gina Lockwood ◽  
...  

2014 ◽  
Vol 75 (S 02) ◽  
Author(s):  
Gerlig Widmann ◽  
P. Schullian ◽  
R. Hoermann ◽  
E. Gassner ◽  
H. Riechelmann ◽  
...  

2005 ◽  
Vol 44 (S 01) ◽  
pp. S58-S60 ◽  
Author(s):  
W. Mohnike

Summary:PET is being considered a diagnostic commodity in clinical practice worldwide and thus receives increasing attention by health insurances and governmental organizations. In Germany, however, neither PET nor PET/CT are subject to reimbursement. This renders clinical PET and PET/CT imaging a challenge both in a general hospital environment and in private practice. This article describes briefly these challenges, which are not solely related to turf battles and associated costs.


Sign in / Sign up

Export Citation Format

Share Document