scholarly journals TTE guided synchronization to optimize AV synchronous leadless pacemaker programming

Author(s):  
George Mawardi ◽  
◽  
Patricia Rodriguez ◽  
Sula Mazimba ◽  
Nishaki Mehta ◽  
...  

Transvenous pacemakers are associated with major complications [1]. Transcatheter leadless pacemaker has reduced the incidence of these complications and the recent accelerometer based atrial sensing algorithm permits restoration of atrioventricular synchrony [1]. We report utilizing cardiac output measurements using Transthoracic Echocardiography (TTE) to determine optimal programming for leadless pacemaker.

Shock ◽  
2016 ◽  
Vol 46 (3) ◽  
pp. 249-253 ◽  
Author(s):  
Paul Wurzer ◽  
Ludwik K. Branski ◽  
Marc G. Jeschke ◽  
Arham Ali ◽  
Michael P. Kinsky ◽  
...  

Author(s):  
Marc-Olivier Fischer ◽  
Xavier Balaire ◽  
Charles Le Mauff de Kergal ◽  
Clément Boisselier ◽  
Jean-Louis Gérard ◽  
...  

2020 ◽  
Vol 12 (1) ◽  
Author(s):  
Geert Koster ◽  
Thomas Kaufmann ◽  
Bart Hiemstra ◽  
Renske Wiersema ◽  
Madelon E. Vos ◽  
...  

Abstract Background Critical care ultrasonography (CCUS) is increasingly applied also in the intensive care unit (ICU) and performed by non-experts, including even medical students. There is limited data on the training efforts necessary for novices to attain images of sufficient quality. There is no data on medical students performing CCUS for the measurement of cardiac output (CO), a hemodynamic variable of importance for daily critical care. Objective The aim of this study was to explore the agreement of cardiac output measurements as well as the quality of images obtained by medical students in critically ill patients compared to the measurements obtained by experts in these images. Methods In a prospective observational cohort study, all acutely admitted adults with an expected ICU stay over 24 h were included. CCUS was performed by students within 24 h of admission. CCUS included the images required to measure the CO, i.e., the left ventricular outflow tract (LVOT) diameter and the velocity time integral (VTI) in the LVOT. Echocardiography experts were involved in the evaluation of the quality of images obtained and the quality of the CO measurements. Results There was an opportunity for a CCUS attempt in 1155 of the 1212 eligible patients (95%) and in 1075 of the 1212 patients (89%) CCUS examination was performed by medical students. In 871 out of 1075 patients (81%) medical students measured CO. Experts measured CO in 783 patients (73%). In 760 patients (71%) CO was measured by both which allowed for comparison; bias of CO was 0.0 L min−1 with limits of agreement of − 2.6 L min−1 to 2.7 L min−1. The percentage error was 50%, reflecting poor agreement of the CO measurement by students compared with the experts CO measurement. Conclusions Medical students seem capable of obtaining sufficient quality CCUS images for CO measurement in the majority of critically ill patients. Measurements of CO by medical students, however, had poor agreement with expert measurements. Experts remain indispensable for reliable CO measurements. Trial registration Clinicaltrials.gov; http://www.clinicaltrials.gov; registration number NCT02912624


CHEST Journal ◽  
2016 ◽  
Vol 150 (4) ◽  
pp. 297A
Author(s):  
Irene Ma ◽  
Joshua Caplin ◽  
Aftab Azad ◽  
Christina Wilson ◽  
Michael Fifer ◽  
...  

2021 ◽  
Vol 48 (6) ◽  
pp. S997
Author(s):  
V. Paranjape ◽  
N. Henao-Guerrero ◽  
G. Menciotti ◽  
F. Garcia-Pereira ◽  
C. Ricco-Pereira

1983 ◽  
Vol 245 (4) ◽  
pp. H690-H692 ◽  
Author(s):  
A. van Grondelle ◽  
R. V. Ditchey ◽  
B. M. Groves ◽  
W. W. Wagner ◽  
J. T. Reeves

We compared 57 cardiac output measurements by the thermodilution and Fick methods in 26 patients and found that thermodilution values were higher in all 16 cases in which Fick outputs were less than 3.5 l/min. In 10 cases where Fick values were less than or equal to 2.5 l/min, thermodilution and Fick measurements differed by an average of 35%. When combined with the results of previous studies comparing the thermodilution, dye dilution, and Fick techniques, these findings suggest that the thermodilution method overestimates true cardiac output in the low output range. This overestimation probably is due to heat loss under conditions of low flow. Because the thermodilution method is used widely in patients with low output states, these findings have potentially important clinical implications.


2012 ◽  
Vol 109 (6) ◽  
pp. 879-886 ◽  
Author(s):  
B. Bataille ◽  
M. Bertuit ◽  
M. Mora ◽  
M. Mazerolles ◽  
P. Cocquet ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document