SIMULTANEOUS ESTIMATION OF METFORMIN HYDROCHLORIDE AND REPAGLINIDE BY HPLC METHOD

INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (01) ◽  
pp. 54-60
Author(s):  
T. Borole ◽  
◽  
M. Dewani ◽  
S. Gandhi ◽  
M. Damle

A reverse phase high performance liquid chromatographic method is developed for the simultaneous determination of metformin hydrochloride and repaglinide. Chromatography was carried out at ambient temperature and separation of these drugs was achieved on neosphere C18 column (150 x 4.6 mm i.d, 3.5 mcgm) as stationary phase with a mobile phase comprising of methanol: 0.05 M acetate buffer (pH 3.5) in ratio of (80:20 V/V) at flow rate 0.8 mL/min. The detection wavelength for metformin hydrochloride and repaglinide was 242 nm. The retention times for metformin hydrochloride and repaglinide were 1.8 0.2 min and 8.9 0.2 min respectively. The linearity of metformin hydrochloride and repaglinide was in the range of 2-10 mcg/mL and 5-25 mcg/mL respectively. The recovery was calculated by standard addition method. The proposed method was found to be suitable for simultaneous determination of metformin hydrochloride and repaglinide.

2013 ◽  
Vol 49 (3) ◽  
pp. 521-528 ◽  
Author(s):  
Viviane Benevenuti Silva ◽  
Angel Arturo Gaona Galdos ◽  
Cintia Maria Alves Mothe ◽  
Michele Bacchi Pallastrelli ◽  
Maria Segunda Aurora Prado ◽  
...  

A simple, rapid, economical and reliable high performance liquid chromatographic method has been developed and successfully applied in simultaneous determination of ethinyl estradiol and drospirenone in coated tablets. The HPLC method was performed on a LiChroCART® 100RP column (125x4 mm i.d., 5 µm) with acetonitrile:water 50:50 (v/v) as mobile phase, pumped at a flow rate of 1.0 mL.min-1. The fluorescence detection for ethinyl estradiol was made at λex= 280 nm and λem= 310 nm and a UV detection for drospirenone was made at 200 nm. The elution time for ethinyl estradiol and drospirenone were 4.0 and 5.7 min, respectively. The method was validated in accordance to USP 34 guidelines. The proposed HPLC method presented advantages over reported methods and is suitable for quality control assays of ethinyl estradiol and drospirenone in coated tablets.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


2009 ◽  
Vol 92 (2) ◽  
pp. 404-409 ◽  
Author(s):  
Abdalla A Elshanawane ◽  
Samia M Mostafa ◽  
Mohamed S Elgawish

Abstract A high-performance liquid chromatographic method was developed for the simultaneous determination of 2 ternary mixtures containing amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone used in hypertension therapy. The use of cyanopropyl column results in satisfactory separation of both mixtures. The mobile phase consisted of 10 mM KH2PO4 buffer (pH 4.5) and methanol in a ratio of (75 25 v/v), at a flow rate of 1 mL/min. UV detector was operated at 275 nm. Calibration graphs were linear in the concentration ranges of 210, 20200, 10100, and 550 g/mL for amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone, respectively. Intraday and interday precision values (relative standard deviation) were &lt;1.13 for mixture I (amiloride hydrochloride, atenolol, chlorthalidone), and &lt;0.93 for mixture II (amiloride hydrochloride, atenolol, hydrochlorothiazide). The method was successfully applied for the determination of the 2 combinations in laboratory-prepared mixtures and commercial pharmaceutical formulation with high accuracy and precision. Statistical comparison of the results with those of the published methods showed excellent agreement and indicates no significant difference between them.


Author(s):  
V Phani Kumar ◽  
Y Sunandamma

A high performance liquid chromatographic method with UV detection was developed and validated for simultaneous determination of Pioglitazone and Clopidogrel. Separation was performed on a C18 column by isocratic elution with a mobile phase of Methanol: Acetonitrile: Water (80:10:10) at pH 4.6. The UV detection was set at 230 nm. The method proved to be specific, accurate, precise and linear over the concentration ranges of 20-120ppm for both Pioglitazone and Clopidogrel with correlation coefficients always >0.999 for both drugs. The intra-day and inter-day precision and accuracy were less than 2 for both analytes. DOI: http://dx.doi.org/10.3329/ijpls.v2i1.14580 International Journal of Pharmaceutical and Life Sciences Vol.2(1) 2013: 1-9