DEVELOPMENT AND VALIDATION OF STABILITY INDICATING RP-HPLC METHOD FOR AMISULPRIDE IN BULK AND PHARMACEUTICAL FORMULATION

INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (04) ◽  
pp. 43-50
Author(s):  
K. M. L Manoja ◽  
◽  
B. M. Gurupadayya ◽  
S Srujana ◽  
L. V. Raaga ◽  
...  

A simple, sensitive, rapid, robust and reproducible method for the determination of amisulpride using paracetamol as internal standard (IS) in bulk and pharmaceutical formulation was developed using reverse phase high performance liquid chromatographic method. The analysis was performed on C18 (250 4.6 mm, 5 mcm) column with a mobile phase consisting of 0.03 M potassium dihydrogen ortho phosphate buffer (pH 6.5), acetonitrile in the ratio of 67:33 (V/V) with a flow rate of 1 mL/min. The analyte was monitored with UV detector at 263 nm. In the developed method amisulpride elutes at retention time of 4.4 min and paracetamol (IS) at 3.3 min. The proposed method is having linearity in the concentration range from 10-100 mcg/mL of amisulpride. The method was validated with respect to system suitability, linearity, precision, limit of detection (LOD) and limit of quantification (LOQ), accuracy (recovery),ruggedness, robustness, stability, forced degradation studies (specificity). The proposed method can be readily utilized for bulk drug and pharmaceutical formulations of amisulpride.

Author(s):  
Sreenivasulu S ◽  
Rameswara Rao M ◽  
Chandra Sekhar KB

A simple, authentic and stability indicating high performance liquid chromatographic method for determination of Canagliflozin in bulk and pharmaceutical formulations was developed and validated as per ICH Q2 R1 Guidelines, A C18 Column (250mm length×4.6 mm diameter x 5 μm particle size) with a mobile phase consisting of Acetonitrile: 1-octanesulphonic acid in a ratio of 70:30 v/v was employed for the chromatographic study. A flow rate of 1.0 mL/min with an injection volume of 20 μL was selected for this study and the proposed method was validated with different parameters such as Linearity, Precision, Accuracy, Robustness, Ruggedness, Limit of Detection (LOD) and Limit of Quantification (LOQ). Canagliflozin was eluted at 3.4 ± 0.5 min and detected at 245 nm. The method is linear over the concentration range of 10-100 μg/mL with correlation co-efficient r = 0.9997. The plate count and tailing factor was found 5398 and 1.05 respectively. The LOD and LOQ were found to be 0.0170 μg/mL and 0.1705 μg/mL respectively. The percentage recovery was achieved in the range of 98-102%, which was within the acceptance criteria. Developed method was employed to determine the amount of Canagliflozinpresent in dosage form (Sulisent). The stabilityof the method was demonstrated by forced degradation studies of drug in which it was degraded under conditions of hydrolysis (acidic and alkaline), oxidation, photolytic and thermal stress as per ICH guideline Q1A (R2).


2010 ◽  
Vol 7 (2) ◽  
pp. 600-604 ◽  
Author(s):  
A. Lakshmana Rao ◽  
V. Naga Jahnavi

A rapid and sensitive high performance liquid chromatographic method was developed for the estimation of levetiracetam in bulk and pharmaceutical formulations. Levetiracetam was chromatographed on a reverse phase C18column in a mobile phase consisting of 0.05 M KH2PO4buffer (pH 3.0 adjusted with orthophosphoric acid) and methanol in the ratio 70:30 v/v. The mobile phase was pumped at a flow rate of 1.2 mL/min. with detection at 210 nm. The detector response was linear in the concentration of 20-120 μg/mL. The limit of detection and limit of quantification was found to be 0.0104 and 0.0317 μg/mL, respectively. The intra and inter day variation was found to be less than 1%. The mean recovery of the drug from the solution containing 100 µg/mL was 100.038 μg/mL. The proposed method is simple, fast, accurate, precise and reproducible hence can be applied for routine quality control analysis of levetiracetam in bulk and pharmaceutical formulations.


2012 ◽  
Vol 9 (2) ◽  
pp. 832-838 ◽  
Author(s):  
Srinivasu Topalli ◽  
T. G. Chandrashekhar ◽  
M. Mathrusri Annapurna

A simple, accurate, sensitive and reproducible reverse phase high performance liquid chromatographic method has been developed for the quantitative determination of Etoricoxib in pharmaceutical dosage forms. The assay was performed on Hypersil ODS C-18 (250 x 4.6 mm., 5µm particle size) column using acetonitrile and potassium dihydrogen phosphate buffer (pH 4.2) (46:54 % v/v) as mobile phase with UV detection at 280 nm (flow rate 1.2 ml/min). Bromhexine was used as an internal standard. Quantization was achieved by measurement of the peak area ratio of the drug to the internal standard. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.0704 µg ml-1and 0.2134 µg ml-1respectively. Each analysis required no longer than 10 minutes. The calibration curve was linear over the concentration range from 0.5-85.0 µg ml-1. The retention times of Etoricoxib and Bromhexine were found to be 3.083 and 7.631 minutes respectively. The proposed method was validated according to the ICH guidelines and can be used successfully to analyse marketed formulations.


2011 ◽  
Vol 8 (s1) ◽  
pp. S41-S46
Author(s):  
Prafulla Kumar Sahu ◽  
M. Mathrusri Annapurna ◽  
Dillipkumar Sahoo

This paper describes a high-performance liquid chromatographic method for simultaneous estimation of nabumetone and paracetamol in binary mixture. The method was based on RP-HPLC separation and quantitation of the two drugs on hypersil C-18 column (250 mm × 4.6 mm) using a mobile phase consisting of acetonitrile and 0.05% aqueous acetic acid (70:30v/v) at flow rate of 1 mL min-1. Quantitation was achieved with PDA detector at 238 nm based on peak area with linear calibration curves at concentration ranges 5-25 µg mL-1for both the drugs. Naproxen sodium was used as internal standard. The method has been successively applied to pharmaceutical formulation. No chromatographic interference from the tablet excipients was found. The method was validated in terms of precision, robustness, recovery and limits of detection and quantitation. The intra and inter-day precision and accuracy values were in the acceptance range as per ICH guidelines.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (03) ◽  
pp. 39-45
Author(s):  
A Sherje ◽  
A. Sonalkar ◽  

A reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of olmesartan medoxomil (OLME) and chlorthalidone (CHLOR) in tablet dosage form. The analysis was performed on Inertsil ODS C18 (250 x 4.6 mm, 5 μ) using KH2PO4 phosphate buffer (pH) and acetonitrile as mobile phase in the proportion of 60: 40 v/v at flow rate of 1.0 mL/min. Detection of drugs was carried out in isocratic mode using UV detector at 275 nm. The retention time of OLME and CHLOR was 13.9 ± 0.1 min. and 4.4 ± 0.5 min., respectively and the total run time was 20 min. The method was validated according to the requirements of the United States Pharmacopeia. The percentage recoveries was found to be in the range of 98.9 - 100.7%. The method was successfully applied to the assay of OLME and CHLOR in tablet dosage form.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


Author(s):  
T Hemant Kumar ◽  
CH. ASHA ◽  
D. GOWRI SANKAR

Objective: To develop and validate a simple, specific, accurate, precise and sensitive reverse phase high performance liquid chromatographic (RP-HPLC) method with forced degradation studies for the simultaneous estimation of amlodipine besylate and irbesartan in the pharmaceutical formulation. Methods: The chromatographic separation of the two drugs were achieved using Enable C 18G column (250 ×4.6 mm; 5 µm) in isocratic mode with mobile phase consisting of sodium acetate buffer (pH 4.0) and acetonitrile (30:70, % v/v) with a flow rate of 0.6 ml/min. Ultraviolet(UV) detection was carried out at 238 nm. The proposed method was validated for linearity, range, accuracy, precision, robustness, limit of detection (LOD) and limit of quantification (LOQ). The tablet formulation was subjected to stress conditions of degradation including acidic, alkaline, oxidative, thermal and photolysis. Results: The retention time for amlodipine besylate and irbesartan were found to be 5.512 and 6.321 min respectively. Linearity was observed over a concentration range 4-32 µg/ml for amlodipine besylate (r2 =0.9999) and 10-70 µg/ml for Irbesartan (r2 =0.9998). The % relative standard deviation (RSD) for Intraday and Interday precision was found to be 0.436 and 0.699 for amlodipine besylate and 0.435 and 0.30 for irbesartan. Amlodipine besylate shown stability towards acidic and thermal whereas in basic, oxidative and photolytic it shown less stability in which it degraded to more extent. Irbesartan shown stability towards thermal conditions whereas in remaining conditions it degrades to more extent especially in oxidative conditions. Conclusion: The developed reverse phase high performance liquid chromatographic (RP-HPLC) method was also found to be simple, precise and sensitive for the simultaneous determination of amlodipine besylate and irbesartan in the tablet dosage form.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
J. Álvarez-Fuentes ◽  
L. Martín-Banderas ◽  
I. Muñoz-Rubio ◽  
M. A. Holgado ◽  
M. Fernández-Arévalo

A simple, fast, and reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for determining of a cannabinoid derivate, which displays potent antihyperalgesic activity, 1-naphthalenyl[4-(pentyloxy)-1-naphthalenyl]methanone (CB13) into PLGA nanoparticles. Separation was achieved in a C18 column using a mobile phase consisting of two solvents: solvent A, consisting of acetonitrile : water : acetic acid (75 : 23.7 : 1.3 v/v), and solvent B, consisting of acetonitrile. An isocratic method (70 : 30 v/v), with a flow rate of 1.000 mL/min, and a diode array detector were used. The developed method was precise, accurate, and linear over the concentration range of analysis with a limit of detection and a limit of quantification of 0.5 and 1.25 μg/mL, respectively. The developed method was applied to the analysis of CB13 in nanoparticles samples obtained by three different procedures (SEV, FF, and NPP) in terms of encapsulation efficiency and drug release. Nanoparticles size and size distribution were also evaluated founding that NPP method presented the most lowest particle sizes with narrow-size distribution (≈320 nm) and slightly negative zeta potential (≈−25 mV) which presumes a suitable procedure for the synthesis of PLGA-CB13 nanoparticles for oral administration.


Sign in / Sign up

Export Citation Format

Share Document