scholarly journals CO2 Laser Surgery and Prosthetic Management for the Treatment of Epulis Fissuratum

2011 ◽  
Vol 2011 ◽  
pp. 1-5 ◽  
Author(s):  
Tarcisio José de Arruda Paes-Junior ◽  
Sâmia Carolina Mota Cavalcanti ◽  
Daniela Fernandes Figueira Nascimento ◽  
Guilherme de Siqueira Ferreira Anzaloni Saavedra ◽  
Estevão Tomomitsu Kimpara ◽  
...  

The aim of this study was to present a case report of the surgical removal of hyperplasia in the oral cavity, using carbon dioxide (CO2) laser radiation and rehabilitation with a complete denture. Epulis fissuratum occurs in complete denture patients, because a constant irritative action induces the mucosa to grow under poorly fitting dentures. These lesions must be removed, and to avoid a relapse, new complete dentures should be made to maintain healthy surgical tissues. The clinical sequence presented in this case shows a completely edentulous patient with epulis fissuratum on the lower alveolar ridge extending to the vestibular sulcus of the anterior region of mandible. Immediate complete dentures were made prior to the lesion removal with CO2 laser radiation, providing satisfactory results in oral function and tissue health.

2014 ◽  
Vol 52 (4) ◽  
pp. 338
Author(s):  
Daejeon Jun ◽  
Dong-Hun Yang ◽  
Mongsook Vang ◽  
Hongso Yang ◽  
Sangwon Park ◽  
...  

2011 ◽  
Vol 3 (2) ◽  
pp. 31-33
Author(s):  
Manasali Bheema Setty ◽  
Nadiger K. Ramesh ◽  
Shaik A Saquib

ABSTRACT Over denture is favoured treatment modality for an elderly patient with few remaining teeth, because of adaptation to wearing is facilitated. Roots maintained under the denture base preserve the alveolar ridge, provide sensory feedback and improve the stability of the dentures. In comparison with complete dentures, overdentures may provide better functions. The most common problem of mandibular complete denture is retention & stability and alveolar ridge resorption; hence care must be taken to preserve it.


2019 ◽  
Vol 53 (6) ◽  
Author(s):  
Michael Josef Kridanto Kamadjaja ◽  
Fatty Nada Pertiwi

It is difficult to make impression and fabricate conventional dentures for patients with microstomia and flat ridge. This is a case report of 53-year-old female with limited mouth opening (25 mm) who had been wearing denture for 7 years and which was recently broken. Close mouth with suction impression method was used. Proper diagnosis and appropriate set of procedures and methods were needed for this patient. The conventional complete denture fitted with closed mouth method for this condition resulted in retentive and stable denture which was inserted and removed easily.


2021 ◽  
Vol 4 (1) ◽  
pp. 53-56
Author(s):  
B Kharel ◽  
A Rai ◽  
P Suwal ◽  
PK Parajuli ◽  
I Limbu ◽  
...  

The present prime concern in dentistry is on preservation of remaining natural teeth. Presence of few teeth in oral cavity help in preserving alveolar ridge integrity, maintain the proprioception, and gives psychological benefit to the patient. Overdenture has proven to be the mainstay of conservative prosthodontic treatment when proper diagnosis, treatment planning, and most importantly, patient compliance are achieved. This paper presents a case report of rehabilitation of a 65 year old patient with multiple missing teeth with tooth supported overdenture in both maxilla and mandible.


2021 ◽  
Vol 7 (2) ◽  
pp. 178-182
Author(s):  
Dr. Claudia Peter ◽  
Dr. Harshini ◽  
Dr. T Sreelal ◽  
Dr. Aparna Mohan ◽  
Dr. Allen Jim Hines ◽  
...  

2012 ◽  
Vol 69 (12) ◽  
pp. 1055-1060 ◽  
Author(s):  
Srdjan Postic

Background/Aim. Balanced occlusal arrangement of artificial teeth and balanced occlusion is a specific type of occlusion that preserves the stability of complete dentures. Balanced occlusion comprises realization of tooth contacts at the working side as well as at the balancing side, at the same time. The aim of this study was to assess the influence of balanced occlusal arrangement of artificial teeth on the decrease in reduction of edentulous alveolar ridge. Methods. A longitudinal study on 91 fully edentulous patients was conducted using their panoramic radiographs and parameters of vertical dimension of edentulous ridges. All the patients were clinically examined by the same and a qualified dental practitioner. Numerical values of parameters of vertical dimensions of edentulous ridges and lines were statistically processed and compared using the Student?s t-test. Results. Vertical dimensions and heights of edentulous ridges were different after comparison of parameters in complete denture wearers with balanced occlusion and complete denture wearers without bilaterally balanced occlusion, as well as between male and female edentulous patients. Statistically significant differences of heights were established in complete denture wearers? with a set of artificial teeth without balanced occlusion, at the baseline and 12 months after wearing of complete dentures. Conclusion. Balanced occlusion is a favored occlusal design in setting of artificial teeth in conventional complete dentures, which preserves edentulous ridge and influence the stability of dentures.


Author(s):  
Takayuki Ueda ◽  
Kaoru Sakurai ◽  
Takashi Koike ◽  
Syuutarou Noda ◽  
Koichiro Ogami

ABSTRACT Purpose The retention of complete dentures is frequently difficult in edentulous patients with a severely resorbed residual alveolar ridge. In such cases, implant overdentures having a stronger retention force are useful. Although there are various types of attachment systems for implant overdentures, they are frequently complicated. We are, therefore, developing a simple attachment system focusing on a soft lining material for the female connector. The purpose of this study was to evaluate the retention force of implant overdentures applying a soft lining material for the attachment. Materials and methods The models in which seven male and female connector pairs were used. As the control, a rubber O-ring attachment system, in which a rubber O-ring female was paired with a metal ball anchor (male), having a diameter of 1.7 or 2.2 mm. In the attachment system with a soft lining material, a female component was made up of soft lining material paired with a male having a diameter of 1.7, 2.2, 2.5, 2.7 or 3.0 mm. In measuring the retention force, the maximum force required to dislodge the male from the female was recorded by a digital force gauge. Results With the rubber O-ring, the retention force was 2.9 ± 0.2 N for the 1.7 mm male and 3.3 ± 0.3 N for the 2.2 mm male; these values were higher than the respective retention forces when using a soft lining material as the female and a male of the same diameter. However, with the female comprising soft lining material, the retention force exceeded 4 N for the 2.5, 2.7 and 3.0 mm males and was higher than the retention forces for the rubber O-ring. Conclusion The proposed attachment system with soft lining material for implant overdentures provides a clinically sufficient retention force when the diameter of the male exceeds 2.5 mm. How to cite this article Koike T, Ueda T, Noda S, Ogami K, Patil PG, Sakurai K. Development of New Attachment System with Soft Lining Material for Implant-retained Complete Denture. Int J Prosthodont Restor Dent 2013;3(1):21-24.


Sign in / Sign up

Export Citation Format

Share Document