scholarly journals Electrothermal Coil Detachment Failure in Flow Diverter-Assisted Coiling of a Small Blister Aneurysm: Technical Considerations and Possible Solutions

Author(s):  
Gwynedd E. Pickett ◽  
Adela Cora

Flow diversion stenting combined with coiling offers both immediate protection from rebleeding for ruptured aneurysms and long-term stability for wide-necked or blister aneurysms. It is particularly useful for tiny ruptured aneurysms, alleviating the concern that small coils may prolapse between the struts of conventional stents. We employed this technique in a very small, broad-based ruptured aneurysm of the internal carotid, jailing the coiling microcatheter with a Pipeline Embolization Device. However, coil detachment repeatedly failed, until we withdrew the detachment zone into the microcatheter. We suggest that if the tip of the coiling catheter is adjacent to the stent, contact between the junction zone of the coil and the high metal density of the flow diverter may prevent proper electrothermal coil detachment. Detachment can be undertaken successfully within the microcatheter, though care must be taken thereafter to fully push the detached coil tail into the aneurysm.

2018 ◽  
Vol 25 (2) ◽  
pp. 182-186
Author(s):  
Manoj Bohara ◽  
Kosuke Teranishi ◽  
Kenji Yatomi ◽  
Takashi Fujii ◽  
Takayuki Kitamura ◽  
...  

Background Flow diversion with the Pipeline embolization device (PED) is a widely accepted treatment modality for aneurysm occlusion. Previous reports have shown no recanalization of aneurysms on long-term follow-up once total occlusion has been achieved. Case description We report on a 63-year-old male who had a large internal carotid artery cavernous segment aneurysm. Treatment with PED resulted in complete occlusion of the aneurysm. However, follow-up angiography at four years revealed recurrence of the aneurysm due to disconnection of the two PEDs placed in telescoping fashion. Conclusion Herein, we present the clinico-radiological features and discuss the possible mechanisms resulting in the recanalization of aneurysms treated with flow diversion.


2021 ◽  
pp. 159101992110491
Author(s):  
Jieun Roh ◽  
Seung Kug Baik ◽  
Jeong A Yeom ◽  
Joo-Young Na ◽  
Sang-Won Lee

The authors report a rare case of sequentially developed bilateral internal carotid artery (ICA) fusiform giant aneurysms in a patient with pathologically confirmed intimal fibroplasia. Both ICA fusiform aneurysms were treated with multiple flow diverter insertion and were well-managed over the past 5.5 years of follow-up. The development of aneurysms in this rare disease entity appears to be a lifelong process based on the authors’ observations in serial angiographic follow-up studies. Reconstruction therapy using flow-diverting stents in this unique condition may be a safe and effective treatment modality.


2018 ◽  
Vol 25 (1) ◽  
pp. 4-11 ◽  
Author(s):  
Anna Luisa Kühn ◽  
Peter Kan ◽  
Visish Srinivasan ◽  
David E Rex ◽  
Katyucia de Macedo Rodrigues ◽  
...  

Background To evaluate the feasibility and efficacy of the pipeline embolization device in the treatment of unruptured intracranial mirror segment aneurysms. Methods Out of a total of 338 subjects, 14 were identified harboring a total of 32 internal carotid artery mirror segment aneurysms that were treated with the pipeline embolization device and were consecutively enrolled into our study. We collected data on patient demographics, modified Rankin scale (mRS) at admission, aneurysm characteristics, clinical outcome at discharge, 3–9 and at 12–18 months as well as angiography results at follow-up. Results Patients’ mean age was 52.9 years; baseline mRS was 0 in all subjects. Pipeline embolization device placement was successful in all cases. Post-treatment mRS remained 0 in 13/14 patients. One patient experienced a small intraparenchymal hemorrhage and subarachnoid hemorrhage, associated with a frontoparietal infarction resulting in right upper extremity weakness and aphasia (post-treatment mRS 3). His mRS evaluation remained stable at the 3–9-month follow-up. Three to 9-month follow-up angiography (13/14 subjects) showed complete aneurysm occlusion in 24/30 aneurysms (80%), near complete and partial occlusion in three of 30 (10%) aneurysms each. At the 9-month follow-up, one patient experienced a complete occlusion of the anterior temporal artery branch but did not present with any clinical deficits. No mRS changes were encountered over a median 6-month follow-up period. Mid-term follow-up angiography (12–18 months) available in eight of 14 subjects showed complete aneurysm occlusion in all patients. Mild intimal hyperplasia was observed in one patient. Conclusions Flow diversion technology can be used for the treatment of unruptured mirror segment aneurysms in selected patients.


2017 ◽  
Vol 14 (4) ◽  
pp. 351-358 ◽  
Author(s):  
Katyucia De Macedo Rodrigues ◽  
Anna Luisa Kühn ◽  
Takamitsu Tamura ◽  
Guilherme Dabus ◽  
Peter Kan ◽  
...  

Abstract BACKGROUND Pericallosal artery aneurysm treatment may be challenging using traditional endovascular techniques. OBJECTIVE To demonstrate the feasibility, efficacy, and safety of endovascular treatment of pericallosal artery aneurysm using flow diverters. METHODS We performed a retrospective review of our institutional database from July 2013 through July 2016 and identified 7 subjects with a pericallosal artery aneurysm treated with the Pipeline embolization device (ev3 Neurovascular, Medtronic, Dublin, Ireland) and at least 1 follow-up angiogram. Technical feasibility, procedural complication, angiographic results, and clinical outcome were evaluated. RESULTS Placement of the Pipeline embolization device was successful in all cases without evidence of procedural complication. Five out of 7 subjects showed a complete aneurysm occlusion at 6- to 12-mo follow-up angiogram. The 2 subjects with persistent aneurysm filling showed decreased aneurysm sac volume on follow-up angiograms (96% and 60%). There was no evidence of in-implant stenosis or intimal hyperplasia. No thromboembolic or hemorrhagic complications were seen during the follow-up period. Only 1 patient had a transient change in Modified Rankin scale score from baseline as a result of different unrelated procedure. CONCLUSION Our preliminary results demonstrate feasibility of the use of flow diverter stent for treatment of aneurysms of the pericallosal artery with rate of aneurysm occlusion comparable to literature and without evidence of increased procedural or short-term morbidity. A long-term and larger cohort study is needed to validate our findings.


2021 ◽  
pp. 159101992110346
Author(s):  
Brendan Ryu ◽  
Timothy G White ◽  
Kevin A Shah ◽  
Justin Turpin ◽  
Thomas Link ◽  
...  

Introduction Quantitative magnetic resonance angiography and non-invasive optimal vessel analysis serve as powerful tools to collect and analyze hemodynamic data from pipeline embolization patients. At our institution, patients receive post-embolization quantitative magnetic resonance angiography within 24 h of treatment and within 6 months for follow-up to evaluate pipeline patency. Here, we aim to elucidate the long-term hemodynamic changes following pipeline embolization device placement and report two cases in which in-stent stenosis was detected. Methods Medical records of patients who underwent pipeline embolization device placement for an internal carotid artery aneurysm between 2017 and 2019 were reviewed. Patients who received post-procedure NOVA and follow-up NOVA were included in the study ( n = 32). Location and size of aneurysm, number of pipeline embolization device deployed, and complications were collected along with the non-invasive optimal vessel analysis report (flow volume rate (ml/min), mean, systolic, and diastolic flow velocities (cm/s), and vessel diameter (mm)). Internal carotid artery vessel flow rate was measured proximal to the pipeline embolization device. Derivations of hemodynamic parameters (pulsatility index, Lindegaard ratio, and wall shear stress) were calculated. Results The middle cerebral artery mean and diastolic flow velocities were significantly lower on the follow-up NOVA compared to the post-procedure NOVA. Moreover, follow-up NOVA demonstrated lower middle cerebral artery wall shear stress on the side with flow diversion compared to the post-procedure NOVA. In-stent stenosis, requiring intervention, was detected in two patients on follow-up NOVA. One patient had a successful balloon angioplasty of the stented internal carotid artery that resolved her stenosis. However, the second patient developed progressive stenosis and expired despite intervention. Conclusion Long-term hemodynamic adaptations post-pipeline embolization device demonstrate decreased wall shear stress and decreased mean and diastolic flow velocities in the distal middle cerebral artery, which suggest decreasing velocity of blood flow with endothelialization of the device. Furthermore, follow-up NOVA is a useful tool for detecting potential flow-related complications such as in-stent stenosis.


2018 ◽  
Vol 113 ◽  
pp. e568-e578 ◽  
Author(s):  
Philippe Dodier ◽  
Josa M. Frischer ◽  
Wei-Te Wang ◽  
Thomas Auzinger ◽  
Ammar Mallouhi ◽  
...  

2012 ◽  
Vol 25 (2) ◽  
pp. 225-230 ◽  
Author(s):  
A. Viglianesi ◽  
R. Chiaramonte ◽  
M. Messina ◽  
G. Conte ◽  
A. D'Amore ◽  
...  

We describe a case of endovascular management of a ruptured aneurysm of the intracavernous portion of the left internal carotid artery with sphenoid extension. The exclusive use of coils to embolize the aneurysm in acute and young patients offers the advantage of avoiding both pre-implant antiplatelet therapy and long-term anticoagulant therapy required after stent or vascular plug placement, but it is complicated by the non-negligible risk of recurrence. Indeed, the only secure method to treat ruptured aneurysms of the intracavernous portion of the internal carotid artery is to use coils in the first stage to stop the haemorrhage without antiplatelet therapy and to use stents in the second narrow stage to prevent revascularization.


2018 ◽  
Vol 28 (2) ◽  
Author(s):  
Guilherme De Palma Abrão ◽  
André Didier Lyra ◽  
Matheus Miranda Barbosa

We describe a case of post-traumatic high-flow carotid-cavernous fistula that was successfully treated with coils and pipeline embolization device. Following the endovascular treatment, the patient experienced clinical improvement of symptoms with complete anatomical restoration of the internal carotid artery.