Electrical Isolation of Superior Vena Cava Besides Pulmonary Vein Isolation by Cryoballoon Technique in a Young Patient with Persistent Atrial Fibrillation

Author(s):  
Ugur Canpolat
2015 ◽  
Vol 31 (9) ◽  
pp. 1562-1569 ◽  
Author(s):  
Sousuke Sugimura ◽  
Takashi Kurita ◽  
Kazuaki Kaitani ◽  
Ryobun Yasuoka ◽  
Shunichi Miyazaki

2020 ◽  
Vol 33 (2) ◽  
pp. 106-114
Author(s):  
Michele Brunelli ◽  
Mark Adrian Sammut

Catheter ablation of long-standing persistent atrial fibrillation is not yet clearly defined with respect to endpoints, and different ablative strategies are offered to patients. Presented here is an approach aiming at biatrial debulking in the form of extensive linear ablation, specifically targeting areas of low-voltage complex fractionated electrograms, in addition to pulmonary vein isolation. Its main advantage is that it is not dependent on operator/system variability, since the strategy of isolating the pulmonary veins, superior vena cava and left atrial posterior wall together with achievement of bidirectional block during linear ablation provides objective endpoints that can consistently be reproduced.


Author(s):  
Hee-jin Kwon ◽  
Dong Seop Jeong ◽  
Hye Ree Kim ◽  
Seung-Jung Park ◽  
Kyoung-Min Park ◽  
...  

Introduction: In patients with non-paroxysmal AF, various ablation strategies have been attempted to target non-pulmonary vein (PV) foci or to achieve substrate modification beyond pulmonary vein isolation (PVI). The efficacy of empirical ablation of the SVC, one of the most common non-PV foci, is unclear. The aim of this study was to investigate the efficacy and safety of additional superior vena cava (SVC) isolation in patients with non-paroxysmal atrial fibrillation (AF) undergoing thoracoscopic surgical ablation. Methods and Results: A total of 191 patients with persistent or longstanding persistent AF was enrolled. All patients underwent total thoracoscopic surgical ablation for AF, and half of them also received empirical SVC isolation. We compared the atrial-tachyarrhythmia (ATa)-free survival rate and procedure-related complications in the two groups of patients. The 3-year ATa-free survival rate was 53% in the SVC-isolation group and 52% in the no-SVC-isolation group, (p = 0.644). There were no differences between the two groups with respect to AF type or LA size. Procedure-related complications occurred in 12 patients (6%). Pacemakers were implanted only in 3 patients from the SVC-isolation group. The only factor influencing recurrence of ATa was LA diameter. Conclusions: Empirical SVC isolation during thoracoscopic ablation for persistent AF did not improve patient outcomes.


Author(s):  
Yasunobu Yamagishi ◽  
Yasushi Oginosawa ◽  
Yoshihisa Fujino ◽  
Keishiro Yagyu ◽  
Taro Miyamoto ◽  
...  

Background: In terms of the pulmonary vein (PV), atrial fibrillation (AF) patients have a shorter effective refractory period (ERP) and a larger dispersion of the ERP than patients without AF. Although the frequency of AF from the superior vena cava (SVC) was the highest among non-PV foci, the characteristics of the ERP in the SVC (SVC-ERP) were unclear. The purpose of this study was to elucidate the relationship between SVC-ERP and the inducibility of AF after pulmonary vein isolation (PVI). Methods and Results: Consecutive 28 patients who underwent PVI were included. After successful PVI, the SVC-ERP was measured at three positions in SVC. Rapid electrical stimuli were delivered at the shortest SVC-ERP to induce AF. Patients in whom AF was induced were assigned to the SVC-induced group (SIG) and the remaining patients were the non-SVC-induced group (non-SIG). The size of the SVC sleeve was evaluated using three-dimensional electroanatomic mapping. The SIG had a significantly shorter average SVC-ERP (236.0±25.2 vs. 294.8±36.8 ms, p<0.001), while SVC-ERP dispersion was not significantly different (30.0±25.4 vs. 33.3±20.1 ms, p=0.56). Although the longer SVC diameter was significantly longer in the SIG (27.4±4.3 vs. 22.9±4.6 mm, p=0.03), the SVC-ERP was significantly associated with pacing inducibility of AF after adjustment for the longer SVC diameter (odds ratio: 0.96 [1-ms increments], p=0.01). Conclusions: The SIG had a shorter SVC-ERP, while the dispersion was not significantly different between the two groups. The SVC-ERP can be one of the mechanisms of arrhythmogenicity for AF originating from the SVC.


Sign in / Sign up

Export Citation Format

Share Document