scholarly journals Vukovar High School Building – investigations and monitoring of a complex geotechnical problem

Author(s):  
Jelena Kaluđer ◽  
Ivan Damjanović ◽  
Krunoslav Minažek
2021 ◽  
Vol 258 ◽  
pp. 09037
Author(s):  
Nina Buzalo ◽  
Irina Platonova ◽  
Nadezhda Tsaritova ◽  
Igor Kosogov

Summarizing the experience of examining school buildings built in rural areas in 1950 - 1990, the article draws conclusions about their technical condition and compliance with the requirements of modern regulatory documents. All surveyed school buildings do not meet the requirements for resistance to heat transfer of enclosing structures, accessibility for all categories of low-mobile groups of the population. The article presents the results of a survey of a high school building in the Oblivsky district of the Rostov region and a high school building in the village of Karaichevskaya in the Rostov region, high school building in the Kuibyshev district of the Rostov region. A number of defects and damages were found in the buildings under investigation. The analysis of the experience of survey of school buildings located in rural areas of the Rostov region.


2018 ◽  
Author(s):  
Lorenza Pistore ◽  
Ilaria Pittana ◽  
Francesca Cappelletti ◽  
Andrea Gasparella ◽  
Piercarlo Romagnoni

2022 ◽  
Vol 8 (2) ◽  
pp. 320-326
Author(s):  
Ermawati

The installation of lightning rods is very necessary for office buildings, buildings, towers so that humans and equipment inside the building are protected from the danger of lightning strikes. This study plans a good lightning rod to be installed in the Pekanbaru Technology High School building by knowing the values ​​of lightning strike density, lightning strike distance, the level of building hazard estimates, determining the area that attracts lightning strikes, determining the number of lightning strikes per year, and determining the radius. protection against lightning strikes. The results of the research that has been carried out, in the Pekanbaru Technological School (STTP) building with a building length of 32.50 m, a building width of 22.50 m, and a building height of 18.00 m. obtained the value of lightning density N_g=35,3602 km²/year, area of ​​attraction for lightning strikes A_e=15,827.49 m², the number of lightning strikes N_d=0,559/year, has level III protection with E=082, area of ​​radius A_x=174.885.44 m², So to be safer from lightning strikes, the STTP building using an electrostatic lightning rod is enough to use 1 finial with a length of 2 m.


Sign in / Sign up

Export Citation Format

Share Document