ASPECTS CONCERNING THE IMPORTANCE OF INSPECTION AND MAINTENANCE OF ELECTRICAL EQUIPMENT WITH TYPE OF PROTECTION FLAMEPROOF ENCLOSURE AND INCREASED SAFETY USED IN LIQUEFIED PETROLEUM GAS CAR FILLING STATION

Author(s):  
Marcel Daniel Rad ◽  
Mihai Magyari ◽  
Lucian Moldovan ◽  
Dragos Fotau ◽  
Diana Salasan
Author(s):  
V.I. Erokhov

The characteristics and master plan of a stationary automobile gas filling station (AGPS) of liquefied petroleum gas (LPG) with ground and underground reservoirs are presented. A schematic diagram of architectural and planning solutions of a stationary gas station is presented. The requirements for the maintenance of the territory, buildings and structures of the gas filling station are set out. The calculation of the required number of filling columns and filling stations is given. The calculation of the gas consumption of LPG AGZS is given. The feature of inspection and filling of LPG storage tanks is formulated. Keywords liquefied hydrocarbon gas; architectural solutions; underground and overground station; exploitation stations; the inspection of tanks; gas equipment; filling tanks; the calculation of fuel dispensers and gas stations


Author(s):  
V.I. Erokhov

Features of operation of the mobile automobile gas filling station (PAGZS) of the liquefied petroleum gas (LPG) are given. A schematic diagram of the planning solutions of the mobile gas station is given. The procedure for refueling vehicles is described. A feature of the operation of the refueling complex on the basis of a mobile gas station is given. The characteristic features of operation and malfunction of the technological equipment of the mobile gas station are given. The safety features of the technological processes of the gas filling station are summarized. The features of gas station maintenance are described. The features of the system of accounting and release of LPG are described. Keywords liquefied petroleum gas; planning solutions; mobile gas filling station; gas filling station operation; gas equipment; LPG refueling; malfunctions and maintenance; gas filling station safety


Author(s):  
B. Ahirwal ◽  
Arvind Kumar Singh ◽  
Rajendra Kumar Vishwakarm

<span lang="EN-US">In the generation of the new technology segment, new explosionproof (Ex) equipment are being installed to make systems suitable for use in hazardous areas of mines. Generally, 80-90% equipment having flameproof (Exd) and intrinsic safety (Exi) methodology of protection are used in the mines for safe operation. The maintenance and safety are two vital parameters to improve the system efficiency of installation in the mines. These parameters are also responsible for the productivity of the mines. The minimum breakdown and maximum safety are the prime concerns of the mines to increase the production. Many observations and basic knowledge are necessary of safety parameters of Ex protections while doing maintenance because micro joules energy is sufficient to ignite the hazardous areas of mines. Trained and skilled personals having good knowledge of Ex protections are required to maintain the limitations of ignition energy sources of Ex equipment to prevent explosion in the mines. A regular and organized scheme of inspection and maintenance may ensure continued, satisfactory and safe operation of Ex electrical equipment in mines. The important points for safety and maintenance of Exd and Exi equipment are pondered in this paper.</span>


2012 ◽  
Vol 190-191 ◽  
pp. 1079-1082 ◽  
Author(s):  
Ming Wei Wang ◽  
Zhan Yao ◽  
Hui Zhen Li

In order to prevent the power system from the failure, an amount of spatially distributed sensors to monitor working conditions of the power equipments are needed. Using the wire cable to transmit the monitoring data usually caused the inconveniences of installation, inspection and maintenance in traditional wire monitoring system. Based on analyzing the advantages of wireless sensor networks (WSNs) and summarizing the key technologies of applying WSNs on monitoring the health of the electrical equipment of the power system, the new design of the power equipment temperature monitoring system based on wireless sensor network is developed in this paper. The new design has been proved to be effective to improve the flexibility, the real-time and the reliability of monitoring the health of power equipment system in practices.


Author(s):  
V.I. Erokhov

The features of the operation of the process equipment of the gas filling station are given. The procedure for refueling vehicles is described. The characteristic features of operation and malfunctions of technological equipment are summarized. The features of technological processes of maintenance of equipment of stationary gas filling stations are described. The characteristics of the current and major repairs are given. The analysis of safety of technological processes of stationary gas filling stations is carried out. The features of the system of accounting for the release of LPG are described. Keywords liquefied petroleum gas; technological equipment; underground and ground station; vehicle refueling; gas equipment; operational and technical characteristics of equipment; malfunctions and maintenance; safety; efficiency and environmental friendliness of


Author(s):  
V.I. Erokhov

The characteristics and parameters of mobile means of transportation and refueling of LPG are given. The characteristics of a mobile automobile gas filling station of frame and frameless construction are analyzed. The basic technological scheme of the APCT-9611 gas tanker is given. The characteristics and operating principle of the shut-off and safety equipment of the transport tank are given. A design diagram of an electric pump for supplying LPG to a mobile gas tanker is presented. A schematic diagram of a reciprocating LPG flow volume Converter is presented. The features of the mechanical and electromagnetic LPG level indicator in a transport tank are described. A schematic diagram of a mobile universal (discharge/filling) gas process module UTMG-01 is shown. Keywords: liquefied petroleum gas; mobile frame and frameless construction of a tanker truck; characteristics and parameters of the station; gas equipment, pumping unit; gas meter; principle and operating modes of the LPG level indicator. [email protected]


Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2988 ◽  
Author(s):  
Dorota Burchart-Korol ◽  
Magdalena Gazda-Grzywacz ◽  
Katarzyna Zarębska

The aim of this publication is to review the current state and possibilities of developing electromobility and alternative fuels in Poland. It was found that the current market for alternative fuels in Poland is insufficiently developed. At the end of 2019 in Poland, liquefied petroleum gas-powered cars accounted for approximately 3.3 million pieces, which amounts to 14.3% all passenger vehicles up to 3.5 tonnes of gross vehicle weight. There were over 9000 electric cars on the road, the share of which accounted for 0.04% of domestic passenger transport. The lack of a sufficient number of charging points, inhibiting the development of electromobility, was also noted. There were approximately 4000 (0.02%) passenger cars powered by compressed natural gas. Liquefied gas-powered vehicles were exclusively public transport vehicles or trucks. The share of biofuels in the Polish transport sector stands at 4%, while European Union requirements are at a level of 10%. Although there is huge potential for the use of hydrogen as an alternative to conventional transport fuels in Poland, just one hydrogen-powered vehicle has been registered in the country so far, with no filling station in existence for this fuel. The synthetic fuel sector is in the planning stage.


A schematic diagram of an underground stationary automobile gas filling station with liquefied petroleum gas (LPG) is presented. The characteristics of a stationary underground storage and refueling tank for LPG vehicles are given. A set of equipment for a stationary ground station of the gas station is given. The features of the underground stationary gas station are described. The principle of operation of a centrifugal LPG supply pump is described. A design diagram of a vortex electric pump for LPG supply is presented. The diagram of the filling clamp with the hose of the filling column of the gas station is shown. The basic scheme of a ground-based stationary gas station is analyzed. The diagram of a self-priming pumping unit of a stationary gas station with underground tanks is shown. The device of a multi-stage compressor for LPG supply is described. The characteristics and principle of operation of the modern LPG filling gun are given. Keywords liquefied petroleum gas; underground and ground filling stations; characteristics of the station; gas equipment of the station; single-stage and multi-stage compressor; operational and technical characteristics; principle and operating modes