scholarly journals Bone Conduction Hearing Loss in Otitis Media.

1996 ◽  
Vol 89 (8) ◽  
pp. 935-942
Author(s):  
Kazuhiro AOKI ◽  
Hiroyuki SEKI ◽  
Fumikazu OOTA ◽  
Hideo INOUE ◽  
Hiroshi MORIYAMA
1999 ◽  
Vol 102 (9) ◽  
pp. 1036-1041 ◽  
Author(s):  
Akihiro Ikui ◽  
Minoru Ikeda ◽  
Yuki Yamauchi ◽  
Yasuyuki Nomura ◽  
Shinya Yoshida ◽  
...  

1993 ◽  
Vol 109 (1) ◽  
pp. 77-82 ◽  
Author(s):  
David O. Merifield ◽  
Nancy J. Parker ◽  
Nannette C. Nicholson

The use of potentially ototoxic topical drugs is controversial. Few experimental reports of audiometric data from human subjects exist. The purpose of this study is to determine if a significant difference between bone conduction hearing sensitivity before and after otic drop treatment for children with chronic suppurative otitis media and patent ventilation tubes exists. A statistical analysis of sensorineural threshold status after treatment of chronic suppurative otitis media with otic drops is presented.


2021 ◽  
Vol 75 (4) ◽  
pp. 1-5
Author(s):  
Joanna Marszał ◽  
Renata Gibasiewicz ◽  
Magdalena Błaszczyk ◽  
Maria Gawlowska ◽  
Wojciech Gawęcki

Introduction: Nowadays, there are many options to treat hearing-impaired patients: tympanoplastic surgery, hearing aids and a wide range of implantable devices. Objective: The aim of this study is to present the mid-term audiological and quality of life benefits after the implantation of the Osia®, a new active piezoelectric bone conduction hearing implant. Material and methods: The state of the tissues in implanted area, as well as audiological and quality of life results were analyzed six, nine and twelve months after implantation in a group of four adult patients with bilateral mixed hearing loss. Results: In all the cases, no postoperative complications were found. One year after surgery the mean audiological gain in FF PTA4 (pure tone average for 0.5, 1, 2, and 4 kHz) was 52.2±3.5 dB in comparison to the unaided situation, the mean speech understanding with Osia® in quiet was 90±8.2% for 50dB SPL, 98.8±2.5% for 65dB SPL and 100±0% for 80dB SPL, and mean speech understanding with Osia® in noise was 37.5%±23.6 for 50dB SPL, 93.8±4.8% for 65dB SPL and 98.8±2.5% for 80dB SPL. There was also an evident improvement in the quality of hearing as well as in the quality of life, measured by the APHAB (Abbreviated Profile of Hearing Aid Benefit) and the SSQ (Speech, Spatial and Qualities of Hearing Scale). Conclusions: The Osia® is an effective treatment option for patients with bilateral mixed hearing loss. The mid-term audiological and quality of life results are excellent, but further observations including bigger groups of patients and a longer follow-up are required.


2020 ◽  
Vol 41 (3) ◽  
pp. 379-385
Author(s):  
Ohad Hilly ◽  
Meirav Sokolov ◽  
Reut Beck Finkel ◽  
Ofir Zavdy ◽  
Rafael Shemesh ◽  
...  

2020 ◽  
Vol 30 (Supplement_2) ◽  
Author(s):  
T Marques ◽  
A Carvalho ◽  
A Miguéis

Abstract Introduction Bone conduction hearing systems can be applied through non-invasive devices, using soft bands that exert pressure on the skin, or they can be surgically implanted (Bone Anchored Hearing Aid - BAHA). However, these bone conduction devices are frequently not well accepted due to the pressure on the head. Therefore, a new non-surgical hearing system was developed not to exert pressure on the skin, the ADHEAR. The bone anchorage in ADHEAR is performed through an adhesive adapter and is indicated for patients with conductive hearing loss and normal inner ear function. Objectives Evaluate the audiological performance with the adhesive bone conduction hearing device (ADHEAR) in a patient with conductive hearing loss. Methodology The study was designed as a prospective single-subject repeated-measure study with the subject serving as his own control. A 29 year old female patient who had a primary surgery due to middle ear cholesteatoma, was adapted with unilateral non-invasive adhesive bone conduction system for the treatment of conductive hearing loss. Air and bone conduction thresholds, word recognition scores (WRS) and speech recognition thresholds (SRT) in quiet and noise were assessed to verify the inclusion criteria of the study. Aided and unaided pure tone audiometry at 0.5, 1, 2 and 4 kHz in free field and speech audiometry in quiet and noise were performed at baseline and after 4 weeks with the ADHEAR. Results The functional gain with the ADHEAR averaged over 0.5, 1, 2, and 4 kHz after 4 weeks of usage of the adhesive hearing system, improved from 55 dB HL to 31dB HL. Speech perception in quiet and noise improved significantly in the aided situation, with SRT in quiet improving from 60 to 35 dB HL, when compared to the unaided condition. Similar results were found in noise. The patient evaluated the ADHEAR system as being useful, and without complaints of skin pressure. There was no adverse skin reaction. Conclusion Hearing performance was significantly better with ADHEAR under all test conditions. Therefore, this transcutaneous hearing system seems to be an excellent alternative for patients who need a hearing solution for conductive hearing loss but for clinical reasons cannot undergo surgery or conventional hearing aids. Furthermore, it preserves skin over the mastoid and reduces the risk of infection. Otherwise it has benefits verified by absence of head pressure and improvement of patient’s quality of life.