Precise Temperature Control of Multi-Input Multi-Output Variable Speed Oil Cooler System Based on Optimal Servo Control Using Genetic Algorithm

Author(s):  
Haeng Rim Oh ◽  
Seok Kwon Jeong
Energies ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 6321
Author(s):  
Jieun Lee ◽  
Seokkwon Jeong

A sliding mode control (SMC) technique based on a state observer with a Kalman filter and feedforward controller was established for a variable-speed refrigeration system (VSRS) to ensure robust control against model uncertainties and disturbances, including noise. The SMC was designed using a state-space model transformed from a practical transfer function model, which was derived by conducting dynamic characteristic experiments. Fewer parameters affecting the model uncertainty were required to be identified, which facilitated modeling. The state observer for estimating the state variables was designed using a Kalman filter to ensure robustness against noise. A feedforward controller was added to the control system to compensate for the deterioration in the transient characteristics due to the saturation function used to avoid chattering. A genetic algorithm was used to alleviate the trial and error involved in determining the design parameters of the saturation function and select optimal values. Simulations and experiments were conducted to verify the control performance of the proposed SMC. The results show that the proposed controller can realize robust temperature control for a VSRS despite stepwise changes in the reference and external heat load, and avoid the trial and error process to design parameters for the saturation function.


2020 ◽  
Author(s):  
Jiang Qian ◽  
Feng Tao ◽  
Dong Yan ◽  
Zhao Xin ◽  
Wang Junyao ◽  
...  

2019 ◽  
Vol 9 (11) ◽  
pp. 2391 ◽  
Author(s):  
Chang-Ming Lin ◽  
Hsin-Yu Liu ◽  
Ko-Ying Tseng ◽  
Sheng-Fuu Lin

The objective of this study was to develop a heating, ventilation, and air conditioning (HVAC) system optimization control strategy involving fan coil unit (FCU) temperature control for energy conservation in chilled water systems to enhance the operating efficiency of HVAC systems. The proposed control strategy involves three techniques, which are described as follows. The first technique is an algorithm for dynamic FCU temperature setting, which enables the FCU temperature to be set in accordance with changes in the outdoor temperature to satisfy the indoor thermal comfort for occupants. The second technique is an approach for determining the indoor cold air demand, which collects the set FCU temperature and converts it to the refrigeration ton required for the chilled water system; this serves as the control target for ensuring optimal HVAC operation. The third technique is a genetic algorithm for calculating the minimum energy consumption for an HVAC system. The genetic algorithm determines the pump operating frequency associated with minimum energy consumption per refrigeration ton to control energy conservation. To demonstrate the effectiveness of the proposed HVAC system optimization control strategy combining FCU temperature control, this study conducted a field experiment. The results revealed that the proposed strategy enabled an HVAC system to achieve 39.71% energy conservation compared with an HVAC system operating at full load.


Sign in / Sign up

Export Citation Format

Share Document