scholarly journals Patterns of oxygen saturation in prolonged recovery from COVID-19 pneumonia

2021 ◽  
Vol 111 (9) ◽  
pp. 849
Author(s):  
F Asmodien ◽  
G Calligaro ◽  
A Husaimen ◽  
N Kwinana ◽  
N Teixeira ◽  
...  
2005 ◽  
Vol 103 (2) ◽  
pp. 269-273 ◽  
Author(s):  
Przemyslaw Jalowiecki ◽  
Robert Rudner ◽  
Maciej Gonciarz ◽  
Piotr Kawecki ◽  
Michal Petelenz ◽  
...  

Background This study evaluated the ability of dexmedetomidine to provide analgesia and sedation for outpatient colonoscopy, examining outcomes including cardiorespiratory variables, side effects, and discharge readiness. Methods Sixty-four patients were randomly assigned to one of three treatment regimens. In group D, patients received 1 microg/kg dexmedetomidine over 15 min followed by an infusion of 0.2 microg x kg x h. Group P received meperidine (1 mg/kg) with midazolam (0.05 mg/kg), and group F received fentanyl (0.1-0.2 mg intravenous) on demand. The assessment included measurements of heart rate, blood pressure, oxygen saturation, respiratory rate, quality of sedation/analgesia, and an evaluation of the recovery time. Results The study was terminated before the planned 90 patients had been recruited because of adverse events in group D. In all groups, negligible hemoglobin oxygen saturation and respiratory rate variations were observed. In group D, there was a significantly larger decrease in heart rate (to approximately 40 beats/min in 2 of 19 cases) and blood pressure (to less than 50% of the initial value in 4 of 19 patients). Supplemental fentanyl was required in 47% of patients receiving dexmedetomidine to achieve a satisfactory level of analgesia (vs. 42.8% of patients in group P and 79.2% of patients in group F). Vertigo (5 patients), nausea/vomiting (5 patients), and ventricular bigeminy (1 patient) were observed only in group D. Time to home readiness was longest in group D (85 +/- 74, 39 +/- 21, and 32 +/- 13 min in groups D, P and F, respectively; P = 0.007). Conclusions The use of dexmedetomidine to provide analgesia/sedation for colonoscopy is limited by distressing side effects, pronounced hemodynamic instability, prolonged recovery, and a complicated administration regimen.


Biomeditsina ◽  
2020 ◽  
pp. 39-46
Author(s):  
A. S. Samoilov ◽  
Yu. D. Udalov ◽  
M. V. Sheyanov ◽  
A. V. Gholinsky ◽  
A. B. Litvinenko

This communication presents the experience of using mobile pressure chambers in patients with the confi rmed novel coronavirus infection in hospital settings. The obtained preliminary results indicate positive antihypoxic effects of hyperbaric oxygen therapy (HBO) applied in the form of increased saturation. After a session of HBO, patients demonstrated an increase in the oxygen saturation of capillary blood hemoglobin at the average level of 3.71 points. Differences between SatO2 levels prior to and following HBO treatment were signifi cant in the CT2, CT3 and CT4 groups (p0.05). As expected, the effi cacy of HBO in terms of the oxygen saturation of capillary blood hemoglobin was the greatest in the patient groups showing pronounced clinical and radiological changes in the lungs.


2017 ◽  
Vol 5 (3) ◽  
pp. 259
Author(s):  
Shireen H. Ramadhan ◽  
Shamil K. Talal ◽  
Wasfiya A. Moner

Tobacco smoke is enormously harmful to human health, there’s no safe way to smoke. The primary objective of this study is to analyze the role of tobacco smoke compounds and their ability to damage the cardiovascular system and, in particular, to interfere with blood pressure (Brachial and radial pressure), heart rate and partly on the percentage blood Oxygen saturation. A new device has been manufactured which is unique for measuring the level of smoke, to obtained privies readings, the device had fixed to the first reference level آ and starting up from it. The effect of smoking has been studied on (26) male passive (26) active smoker volunteer, (14) female passive and (14) female active smoker participants. The results has been showed that the blood pressure and heart rate has been increased with increasing the number of cigarettes in both genders for passive and active smokers. However, this effect for male was more pronounced comparing with females for passive and active smokers. In the case of oxygen saturation concentration percentage, for males the change of oxygen concentration percentage was not stable. In other words, it was fluctuated with the number of cigarettes. But for females the oxygen concentration was decreased but not too much. This means that this effect was not pronounced. this study found آ that the most pronounced effect has been shown by male’s comparison to females for both passive and active smokers. As well as in nonsmoker’s males, the relation between heart rate and smoke level is inversely proportional. While in male and female smokers and female nonsmokers the relation is proportional. In all cases the relation between the smoke level and time of smoking is inversely proportional. Finally males& females are affected differently by tobacco use; the sensitivities to smoke for males are higher than in females for passive and active smokers in both brachial and radial blood pressure measurement.


Sign in / Sign up

Export Citation Format

Share Document