Aortic Stenosis as an Additional Finding in Low-Dose Computed Tomography Lung Cancer Screening: A Cross-Sectional Study

2021 ◽  
Author(s):  
Kaja Klein-Awerjanow ◽  
Witold Rzyman ◽  
Marcin Ostrowski ◽  
Jadwiga Fijalkowska ◽  
Edyta Szurowska ◽  
...  
2019 ◽  
Vol 65 (2) ◽  
pp. 224-233
Author(s):  
Sergey Morozov ◽  
Viktor Gombolevskiy ◽  
Anton Vladzimirskiy ◽  
Albina Laypan ◽  
Pavel Kononets ◽  
...  

Study aim. To justify selective lung cancer screening via low-dose computed tomography and evaluate its effectiveness. Materials and methods. In 2017 we have concluded the baseline stage of “Lowdose computed tomography in Moscow for lung cancer screening (LDCT-MLCS)” trial. The trial included 10 outpatient clinics with 64-detector CT units (Toshiba Aquilion 64 and Toshiba CLX). Special low-dose protocols have been developed for each unit with maximum effective dose of 1 mSv (in accordance with the requirements of paragraph 2.2.1, Sanitary Regulations 2.6.1.1192-03). The study involved 5,310 patients (53% men, 47% women) aged 18-92 years (mean age 62 years). Diagnosis verification was carried out in the specialized medical organizations via consultations, additional instrumental, laboratory as well as pathohistological studies. The results were then entered into the “National Cancer Registry”. Results. 5310 patients (53% men, 47% women) aged 18 to 92 years (an average of 62 years) participated in the LDCT-MLCS. The final cohort was comprised of 4762 (89.6%) patients. We have detected 291 (6.1%) Lung-RADS 3 lesions, 228 (4.8%) Lung- RADS 4A lesions and 196 (4.1%) Lung-RADS 4B/4X lesions. All 4B and 4X lesions were routed in accordance with the project's methodology and legislative documents. Malignant neoplasms were verified in 84 cases (1.76% of the cohort). Stage I-II lung cancer was actively detected in 40.3% of these individuals. For the first time in the Russian Federation we have calculated the number needed to screen (NNS) to identify one lung cancer (NNS=57) and to detect one Stage I lung cancer (NNS=207). Conclusions. Based on the global experience and our own practices, we argue that selective LDCT is the most systematic solution to the problem of early-stage lung cancer screening.


2020 ◽  
Vol 58 (228) ◽  
Author(s):  
Chitaranjan Shah ◽  
Robin Bahadur Basnet ◽  
Arvind Shah ◽  
Prakash Chhettri ◽  
Anup Chapagain ◽  
...  

Introduction: Percutaneous nephrolithotomy has the highest stone free rate among other procedures with relatively higher complication rate. Post-operative imaging after stone surgeries has not been uniform. This study was done to study about the stone clearance by computed tomography after percutaneous nephrolithotomy. Methods: The descriptive cross-sectional study was conducted in the Department of Urology, Bir Hospital for six months duration. The patients undergoing percutaneous nephrolithotomy and those with intra-operative fluoroscopic clearance were evaluated with a low dose computed tomography after 48 hours to assess residual fragments its size and location. Patient’s demographics, stone characteristics and complications were compared between the stone free and with residual stone patients. Results: Out of 72 percutaneous nephrolithotomy performed, 40 patients were included in the study. Low dose computed tomography kidney, ureter and bladder after 48 hours of surgery detected residual fragments in 11 (27.5%) patients. The RFs size of <4mm were found in 7 (63.63%) of cases whereas RFs of >4mm were found in 4 (36.36%). The stone size was 352.47 ± 97.47 mm2 and 254.79 ± 172.68mm2 in group with residual fragments and stone free group respectively. Conclusions: Low dose computed tomography kidney, ureter and bladder done for assessment of stone clearance after 48 hours of percutaneous nephrolithomy detected residual in around one fourth of patients, however majority of them had residual fragments <4mm. Intra-operative fluoroscopic clearance may over estimate stone clearance after percutaneous nephrolithomy as about one third of patients still may have residual fragments of >4mm size.


2021 ◽  
Vol 16 (10) ◽  
pp. S1176
Author(s):  
L. Jungblut ◽  
J. Walter ◽  
C. Zellweger ◽  
M. Patella ◽  
D. Franzen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document