Creation of super-resolution hollow beams with long depth of focus using binary optics

2019 ◽  
Vol 13 (1) ◽  
pp. 012003 ◽  
Author(s):  
Ning Xu ◽  
Guoxuan Liu ◽  
Zhe Kong ◽  
Qiaofeng Tan
1996 ◽  
Author(s):  
Tohru Ogawa ◽  
Masaya Uematsu ◽  
Koichi Takeuchi ◽  
Atsushi Sekiguchi ◽  
Tatsuji Oda

Sensors ◽  
2020 ◽  
Vol 20 (23) ◽  
pp. 6791
Author(s):  
Gyeongsik Ok ◽  
Kee Jai Park

The Bessel–Gauss beam has outstanding features, such as long depth of focus (DOF) and super resolution for nondestructive imaging inspection. However, most approaches for generating a nondiffractive beam have mainly focused on extending the DOF. In this study, the ultra-long high-resolution Bessel–like beam was first demonstrated in a sub-THz wave range (140 GHz). An axicon lens having an apex angle of 110° was used to generate the highly focused Bessel–like beam. To extend the depth of focus, we varied the incident beam angle on the axicon by moving the first lens distance. With the newly developed beam profiler, 3D beam profiles were acquired for characterizing in detail the beam propagation. As a result, even if the depth of focus was 72 times (154 mm) the source wavelength (2.143 mm), the focusing beamwidth was simultaneously maintained at 1.4 times (3.0 mm) the wavelength (i.e., the near-wavelength beamwidth). An ultra-long needle beam of near-wavelength size can promote the applicability of the sub-THz imaging technique in noninvasive sensing applications, such as computer tomography, materials inspection, and through-the-wall-imaging.


Author(s):  
M.D. Coutts ◽  
E.R. Levin ◽  
J.G. Woodward

While record grooves have been studied by transmission electron microscopy with replica techniques, and by optical microscopy, the former are cumbersome and restricted and the latter limited by lack of depth of focus and resolution at higher magnification. With its great depth of focus and ease in specimen manipulation, the scanning electron microscope is admirably suited for record wear studies.A special RCA sweep frequency test record was used with both lateral and vertical modulation bands. The signal is a repetitive, constant-velocity sweep from 2 to 20 kHz having a duration and repetitive rate of approximately 0.1 sec. and a peak velocity of 5.5 cm/s.A series of different pickups and numbers of plays were used on vinyl records. One centimeter discs were then cut out, mounted and coated with 200 Å of gold to prevent charging during examination. Wear studies were made by taking micrographs of record grooves having 1, 10 and 50 plays with each stylus and comparing with typical “no-play” grooves. Fig. 1 shows unplayed grooves in a vinyl pressing with sweep-frequency modulation in the lateral mode.


Acta Naturae ◽  
2017 ◽  
Vol 9 (4) ◽  
pp. 42-51
Author(s):  
S. S. Ryabichko ◽  
◽  
A. N. Ibragimov ◽  
L. A. Lebedeva ◽  
E. N. Kozlov ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document