Artificial Aging Characteristics of Hydrophobic Hanjis Grafted by Gaseous Palmitoyl Chloride

Author(s):  
Kyoung-Hwa Choi ◽  
Kwang Seob Lee ◽  
Jae-Hoon Lee ◽  
Myoung-Ku Lee ◽  
Jeong-Yong Ryu
Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 3920
Author(s):  
Allegra Comba ◽  
Andrea Baldi ◽  
Riccardo Michelotto Tempesta ◽  
Massimo Carossa ◽  
Letizia Perrone ◽  
...  

This study evaluated the effectiveness of chemical-based adhesive techniques on promoting immediate and aged bond strength between zirconia and luting cement. A total of 128 discs of zirconia were divided into 4 groups (n = 32) according to the adhesive treatment: tribochemical silica-coating followed by silane (Silane Primer, Kerr) and bonding (Optibond FL, Kerr), Signum Zirconia Bond (Hereaus), Z-Prime Plus (Bisco), and All-Bond Universal (Bisco). Composite cylinders were cemented on the zirconia sample with Duo-Link Universal (Bisco). Eight specimens per group were subjected to 10,000 thermocycles and subsequently bond strength was tested with shear-bond strength test. ANOVA test showed that artificial aging significantly affected the bond strength to zirconia. Bonferroni test highlighted a significant influence of adhesive treatment (Signum) on bond strength after thermocycling. It was concluded that 10-MDP-based bonding systems showed no improvement in initial bond strength compared with tribochemical treatment. All chemical bonding techniques tested in this study were influenced by thermocycling.


Author(s):  
D. C. Gornig ◽  
R. Maletz ◽  
P. Ottl ◽  
M. Warkentin

Abstract Objective The aim of the study was to evaluate the influence of filler content, degradation media and time on the mechanical properties of different dental composites after in vitro aging. Materials and Methods Specimens (1 mm3) of three commercially available composites (GrandioSO®, Arabesk Top®, Arabesk Flow®) with respect to their filler content were stored in artificial aging media: artificial saliva, ethanol (60%), lactic acid (pH 5) and citric acid (pH 5). Parameters (Vickers microhardness, compressive strength, elastic modulus, water sorption and solubility) were determined in their initial state (control group, n = 3 for microhardness, n = 5 for the other parameters) and after 14, 30, 90 and 180 days (n = 3 for microhardness, n = 5 for the other parameters for each composite group, time point and media). Specimens were also characterized with dynamic-mechanical-thermal analysis (compression tests, F =  ± 7 N; f = 0.5 Hz, 1 Hz and 3.3 Hz; t = 0–170 °C). Results Incorporation of fillers with more than 80 w% leads to significantly better mechanical properties under static and dynamic compression tests and a better water sorption behavior, even after chemical degradation. The influence of degradation media and time is of subordinate importance for chemical degradation. Conclusion Although the investigated composites have a similar matrix, they showed different degradation behavior. Since dentine and enamel occur only in small layer thickness, a test specimen geometry with very small dimensions is recommended for direct comparison. Moreover, the use of compression tests to determine the mechanical parameters for the development of structure-compatible and functionally adapted composites makes sense as an additional standard. Clinical relevance Preferential use of highly filled composites for occlusal fillings is recommended.


2011 ◽  
Vol 92 (2) ◽  
pp. 343-350
Author(s):  
Leonardo Petruzzi ◽  
Antonio Bevilacqua ◽  
Claudio Ciccarone ◽  
Giuseppe Gambacorta ◽  
Giuseppina Irlante ◽  
...  

2011 ◽  
Vol 105 (4) ◽  
pp. 236-241 ◽  
Author(s):  
Anderson Catelan ◽  
André Luiz Fraga Briso ◽  
Renato Hermann Sundfeld ◽  
Marcelo Coelho Goiato ◽  
Paulo Henrique dos Santos

Sign in / Sign up

Export Citation Format

Share Document