volume effects
Recently Published Documents


TOTAL DOCUMENTS

884
(FIVE YEARS 69)

H-INDEX

65
(FIVE YEARS 5)

2021 ◽  
Vol 17 (S1) ◽  
Author(s):  
Matthew R. Scott ◽  
Natalie C Edwards ◽  
Michael J Properzi ◽  
Heidi I.L. Jacobs ◽  
Julie C Price ◽  
...  

Author(s):  
Tiana Lehmer ◽  
Ben Lourie ◽  
Devin Shanthikumar

AbstractUsing unique new data, we examine whether brokerage trading volume creates a conflict of interest for analysts. We find that earnings forecast optimism is associated with higher brokerage volume, even controlling for forecast and analyst quality, recommendations, and target prices. However, forecast accuracy is also significantly associated with higher volume. When analysts change brokerage houses, they bring trading volume with them, influencing trading volume at the new brokerage. This indicates that analysts drive the volume effects we observe. Consistent with a reward for generating volume, brokerage houses are less likely to demote analysts who generate more volume. Finally, analysts strategically adjust forecast optimism based on expected volume impact. Analysts become more (less) optimistic if their optimistic forecasts in the prior year were more (less) successful at generating volume. However, consistent with higher costs to increasing accuracy, analysts do not update accuracy based on expected volume impact. Overall, our results are consistent with a brokerage trading volume conflict of interest moving analysts towards more optimistic earnings forecasts, despite the volume reward for accuracy.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Chiraz Labidi ◽  
Dorra Laribi ◽  
Loredana Ureche-Rangau

PurposeThis study explores the price and trading volume effects around the quarterly Dow Jones Islamic Market-GCC index (DJIM-GCC) revisions and investigates whether these reactions are driven by firms' fundamentals or by investors' perception of ethical screening.Design/methodology/approachThe authors adopt an event study methodology to analyze the price and volume effects of Islamic indices redefinitions.FindingsThe results exhibit a positive (negative) price reaction for added (deleted) stocks. The authors also document an asymmetric volume response for index additions and deletions. The multivariate analysis of the cumulative abnormal returns reveals that the documented market reaction around Islamic index revisions is mainly related to the compliance attribution (withdrawal).Originality/valueThe approach allows to separate the market reaction arising from changes in firms' fundamentals from that induced by investors' perception of the attribution or withdrawal of a compliance certification. Moreover, the focus on the GCC region, where countries share the same cultural traits and perceive Islamic law identically excludes any social effect that would influence the market reaction due to cultural differences between countries.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
S. Peter Kim ◽  
Daniel Juneau ◽  
Claire Cohalan ◽  
Shirin A. Enger

Abstract Background Multiple post-treatment dosimetry methods are currently under investigation for Yttrium-90 ($$^{90}\hbox {Y}$$ 90 Y ) radioembolization. Within each methodology, a variety of dosimetric inputs exists that affect the final dose estimates. Understanding their effects is essential to facilitating proper dose analysis and crucial in the eventual standardization of radioembolization dosimetry. The purpose of this study is to investigate the dose differences due to different self-calibrations and mass density assignments in the non-compartmental and local deposition methods. A practical mean correction method was introduced that permits dosimetry in images where the quality is compromised by patient motion and partial volume effects. Methods Twenty-one patients underwent $$^{90}\hbox {Y}$$ 90 Y radioembolization and were imaged with SPECT/CT. Five different self-calibrations (FOV, Body, OAR, Liverlung, and Liver) were implemented and dosimetrically compared. The non-compartmental and local deposition method were used to perform dosimetry based on either nominal- or CT calibration-based mass densities. A mean correction method was derived assuming homogeneous densities. Cumulative dose volume histograms, linear regressions, boxplots, and Bland Altman plots were utilized for analysis. Results Up to 270% weighted dose difference was found between self-calibrations with mean dose differences up to 50 Gy in the liver and 23 Gy in the lungs. Between the local deposition and non-compartmental methods, the liver and lung had dose differences within 0.71 Gy and 20 Gy, respectively. The local deposition method’s nominal and CT calibration-based mass density implementations dosimetric metrics were within 1.4% in the liver and 24% in the lungs. The mean lung doses calculated with the CT method were shown to be inflated. The mean correction method demonstrated that the corrected mean doses were greater by up to $$\sim 5$$ ∼ 5 Gy in the liver and lower by up to $$\sim 12$$ ∼ 12 Gy in the lungs. Conclusions The OAR calibration may be utilized as a potentially more accurate and precise self-calibration. The non-compartmental method was found more comparable to the local deposition method in organs that were more homogeneous in mass densities. Due to the potential for inflated lung mean doses, the non-compartmental and local deposition method implemented with nominal mass densities is recommended for more consistent dosimetric results. If patient motion and partial volume effects are present in the liver, our practical correction method will calculate more representative doses in images suboptimal for dosimetry.


Meccanica ◽  
2021 ◽  
Author(s):  
Somayeh Mashayekhi ◽  
Eugenia Stanisauskis ◽  
Mahdi Hassani ◽  
William Oates

2021 ◽  
Vol 2021 (7) ◽  
Author(s):  
Andrey Yu. Kotov ◽  
Daniel Nogradi ◽  
Kalman K. Szabo ◽  
Lorinc Szikszai

Abstract In previous work, [arXiv:1905.01909], we have calculated the mϱ/fπ ratio in the chiral and continuum limit for SU(3) gauge theory coupled to Nf = 2, 3, 4, 5, 6 fermions in the fundamental representation. The main result was that this ratio displays no statistically significant Nf-dependence. In the present work we continue the study of the Nf-dependence by extending the simulations to Nf = 7, 8, 9, 10. Along the way we also study in detail the Nf-dependence of finite volume effects on low energy observables and a particular translational symmetry breaking unphysical, lattice artefact phase specific to staggered fermions.


2021 ◽  
Vol 25 (03) ◽  
pp. 514-526
Author(s):  
Benjamin Fritz ◽  
Jan Fritz ◽  
Reto Sutter

AbstractMagnetic resonance imaging (MRI) is a powerful imaging modality for visualizing a wide range of ankle disorders that affect ligaments, tendons, and articular cartilage. Standard two-dimensional (2D) fast spin-echo (FSE) and turbo spin-echo (TSE) pulse sequences offer high signal-to-noise and contrast-to-noise ratios, but slice thickness limitations create partial volume effects. Modern three-dimensional (3D) FSE/TSE pulse sequences with isotropic voxel dimensions can achieve higher spatial resolution and similar contrast resolutions in ≤ 5 minutes of acquisition time. Advanced acceleration schemes have reduced the blurring effects of 3D FSE/TSE pulse sequences by affording shorter echo train lengths. The ability for thin-slice partitions and multiplanar reformation capabilities eliminate relevant partial volume effects and render modern 3D FSE/TSE pulse sequences excellently suited for MRI visualization of several oblique and curved structures around the ankle. Clinical efficiency gains can be achieved by replacing two or three 2D FSE/TSE sequences within an ankle protocol with a single isotropic 3D FSE/TSE pulse sequence. In this article, we review technical pulse sequence properties for 3D MRI of the ankle, discuss practical considerations for clinical implementation and achieving the highest image quality, compare diagnostic performance metrics of 2D and 3D MRI for major ankle structures, and illustrate a broad spectrum of ankle abnormalities.


Author(s):  
Yvette Seppenwoolde ◽  
Katarina Majercakova ◽  
Martin Buschmann ◽  
Elke Dörr ◽  
Alina E. Sturdza ◽  
...  

Abstract Purpose Predicting morbidity for patients with locally advanced cervix cancer after external beam radiotherapy (EBRT) based on dose–volume parameters remains an unresolved issue in definitive radiochemotherapy. The aim of this prospective study was to correlate patient characteristics and dose–volume parameters to various early morbidity endpoints for different EBRT techniques, including volumetric modulated arc therapy (VMAT) and adaptive radiotherapy (ART). Methods and materials The study population consisted of 48 patients diagnosed with locally advanced cervix cancer, treated with definitive radiochemotherapy including image-guided adaptive brachytherapy (IGABT). Multiple questionnaires (CTCAE 4.03, QLQ-C30 and EORTC QLQ-CX24) were assessed prospectively for patients treated with different EBRT techniques, including online adaptive VMAT. Contouring and treatment planning was based on the EMBRACE protocols. Acute toxicity, classified as general, gastrointestinal (GI) or genitourinary (GU) and their corresponding dose–volume histograms (DVHs) were first correlated by applying least absolute shrinkage and selection operator (LASSO) and subsequently evaluated by multiple logistic binomial regression. Results The treated EBRT volumes varied for the different techniques with ~2500 cm3 for 3D conformal radiotherapy (3D-CRT), ~2000 cm3 for EMBRACE‑I VMAT, and ~1800 cm3 for EMBRACE-II VMAT and ART. In general, a worsening of symptoms during the first 5 treatment weeks and recovery afterwards was observed. Dose–volume parameters significantly correlating with stool urgency, rectal and urinary incontinence were as follows: bowel V40Gy < 250 cm3, rectum V40Gy < 80% and bladder V40Gy < 80–90%. Conclusion This prospective study demonstrated the impact of EBRT treatment techniques in combination with chemotherapy on early morbidity. Dose–volume effects for dysuria, urinary incontinence, stool urgency, diarrhea, rectal bleeding, rectal incontinence and weight loss were found.


Sign in / Sign up

Export Citation Format

Share Document