clock drift
Recently Published Documents


TOTAL DOCUMENTS

89
(FIVE YEARS 22)

H-INDEX

9
(FIVE YEARS 2)

2021 ◽  
Author(s):  
Jihao Sun ◽  
Pengchong Chen ◽  
Ying Luo

Abstract Ethernet Control Automation Technology (EtherCAT) applies distributed clock (DC) to realize synchronization among different slaves. Due to the influence of the crystal oscillator manufacturing process and environment, there is still synchronization error between reference clock and non-reference clock. To solve the clock synchronization problem, this paper proposes a clock drift compensation algorithm based on the idea of closed-loop control. By designing integer-order proportional integral (IOPI) and fractional-order proportional integral (FOPI) controllers, the synchronization error between slaves can be minimized. The IOPI and FOPI controllers designed in this paper are used to eliminate the drift error. This method improves the synchronization accuracy without bringing too much computational load. The results show that the proposed FOPI controller can effectively reduce the synchronization error with even better performance over the IOPI controller.


2021 ◽  
Vol 149 (6) ◽  
pp. 4094-4105
Author(s):  
Ludovic Tenorio-Hallé ◽  
Aaron M. Thode ◽  
Steven L. Swartz ◽  
Jorge Urbán R.

2021 ◽  
Author(s):  
David Naranjo ◽  
Laura Parisi ◽  
Philippe Jousset ◽  
Cornelis Weemstra ◽  
Sigurjón Jónsson

<p>Accurate timing of seismic records is essential for almost all applications in seismology. Wrong timing of the waveforms may result in incorrect Earth models and/or inaccurate earthquake locations. As such, it may render interpretations of underground processes incorrect. Ocean bottom seismometers (OBSs) experience clock drifts due to their inability to synchronize with a GNSS signal (with the correct reference time), since electromagnetic signals are unable to propagate efficiently in water. As OBSs generally operate in relatively stable ambient temperature, the timing deviation is usually assumed to be linear. Therefore, the time corrections can be estimated through GPS synchronization before deployment and after recovery of the instrument. However, if the instrument has run out of power prior to recovery (i.e., due to the battery being dead at the time of recovery), the timing error at the end of the deployment cannot be determined. In addition, the drift may not be linear, e.g., due to rapid temperature drop while the OBS sinks to the seabed. Here we present an algorithm that recovers the linear clock drift, as well as a potential timing error at the onset.</p><p>The algorithm presented in this study exploits seismic interferometry (SI). Specifically, time-lapse (averaged) cross-correlations of ambient seismic noise are computed. As such, virtual-source responses, which are generally dominated by the recorded surface waves, are retrieved. These interferometric responses generate two virtual sources: a causal wave (arriving at a positive time) and an acausal wave (arriving at a negative time). Under favorable conditions, both interferometric responses approach the surface-wave part of the medium's Green's function. Therefore, it is possible to calculate the clock drift for each station by exploiting the time-symmetry between the causal and acausal waves. For this purpose, the clock drift is calculated by measuring the differential arrival times of the causal and acausal waves for a large number of receiver-receiver pairs and computing the drift by carrying-out a least-squares inversion. The methodology described is applied to time-lapse cross-correlations of ambient seismic noise recorded on and around the Reykjanes peninsula, SW Iceland. The stations used for the analysis were deployed in the context of IMAGE (Integrated Methods for Advanced Geothermal Exploration) and consisted of 30 on-land stations and 24 ocean bottom seismometers (OBSs).  The seismic activity was recorded from spring 2014 until August 2015 on an area of around 100 km in diameter (from the tip of the Reykjanes peninsula).</p>


2021 ◽  
pp. 56-66
Author(s):  
Nikolay N. Vasilyuk ◽  
Alexander P. Chervonkin

The problem of the synchronization of onboard clocks of navigation satellites has considered from a relativistic point of view using the concept of “coordinate simultaneity”. This concept allows an unambiguous interpretation of the synchronization results within the framework of general relativity. The algorithm of intersatellite measurements processing has formulated in terms of a proper time of a space vehicle and the coordinate time of a reference frame. Rules of transformation between coordinate and proper time scales have indicated. An analytical expression has obtained for the periodic relativistic correction to the estimated value of the relative clock drift. This correction has expressed in terms of the coordinate time of a ground observer. The value of this correction exceeds the acceptable synchronization error and should be taken into account for the inter-satellite measurements processing. The error of the relativistic correction determination has calculated. This error provides an upper limit for the period of uploading of ephemeris data on the board of the space vehicle.


Author(s):  
Sihao Zhao ◽  
Xiao-Ping Zhang ◽  
Xiaowei Cui ◽  
Mingquan Lu
Keyword(s):  

2021 ◽  
pp. 1-1
Author(s):  
Sihao Zhao ◽  
Ningyan Guo ◽  
Xiao-Ping Zhang ◽  
Xiaowei Cui ◽  
Mingquan Lu
Keyword(s):  

2021 ◽  
Vol 28 ◽  
pp. 578-582
Author(s):  
Sihao Zhao ◽  
Xiao-Ping Zhang ◽  
Xiaowei Cui ◽  
Mingquan Lu

Sign in / Sign up

Export Citation Format

Share Document