electric field measurement
Recently Published Documents


TOTAL DOCUMENTS

198
(FIVE YEARS 30)

H-INDEX

21
(FIVE YEARS 2)

2021 ◽  
Author(s):  
Yang Liu ◽  
Zongde Li ◽  
Yuanyuan Dai ◽  
Xiaofeng Zhang ◽  
Haichen Wu ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-15
Author(s):  
Chunguang Suo ◽  
Ran Wei ◽  
Wenbin Zhang ◽  
Yincheng Li

It is of great significance to accurately provide electric field information for electric power operators and electric power inspection equipment to ensure the safety of live working robots and electric power workers. In this paper, the principle of parallel plate charge induction is used to detect electric field signals and the influence of the inherent capacitance of the parallel plate on the back-end circuit is considered. An equipotential ring is used as the structure of the sensing unit to eliminate the uncertainty generated by the edge electric field. The parameters of the sensor probe are determined by the principle of differential-integration, and its structure is analyzed and designed. The consistency of the designed sensor probe was analyzed, and the results show that the consistency of the sensor is better. We have measured the sensitivity coefficients of the six probes, and the average absolute deviation reached 0.031556. The fits were all above 0.9995. In addition, a three-dimensional power frequency electric field measurement system that is easy to manufacture is designed using the hexahedral structure, which solves the problem of inaccurate electric field measurement caused by the parallel plate probe and the field source being not perpendicular, and the combined field strength formula of nonuniform electric field was obtained. In the laboratory environment, the three-dimensional power frequency electric field measurement system produced in this paper is compared with the electric field simulated by an electric field simulation tool. The test results show that the deviation between the measurement system and simulation is within ±0.55%, the measurement range is 1 kV/m–200 kV/m, the resolution is ≥1 V/m, and the maximum electric field can be measured at 200 kV/m. The nonlinear error is 2.15%, and the sensitivity coefficient is 19.10   mV / kV · m − 1 , which meets the measurement requirements of the power frequency electric field and can be applied to the actual power frequency electric field measurement.


Author(s):  
Zhang Yu ◽  
Zheng Feihu ◽  
Chen Shijie ◽  
Chen Guanwen ◽  
Zhang Yewen

Optica ◽  
2021 ◽  
Author(s):  
William Peters ◽  
Travis Jones ◽  
Anatoly Efimov ◽  
Emanuele Pedersoli ◽  
Laura Foglia ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document