heart sounds
Recently Published Documents


TOTAL DOCUMENTS

1043
(FIVE YEARS 157)

H-INDEX

36
(FIVE YEARS 6)

2022 ◽  
Author(s):  
Mahbubeh Bahreini ◽  
Ramin Barati ◽  
Abbas Kamaly

Abstract Early diagnosis is crucial in the treatment of heart diseases. Researchers have applied a variety of techniques for cardiovascular disease diagnosis, including the detection of heart sounds. It is an efficient and affordable diagnosis technique. Body organs, including the heart, generate several sounds. These sounds are different in different individuals. A number of methodologies have been recently proposed to detect and diagnose normal/abnormal sounds generated by the heart. The present study proposes a technique on the basis of the Mel-frequency cepstral coefficients, fractal dimension, and hidden Markov model. It uses the fractal dimension to identify sounds S1 and S2. Then, the Mel-frequency cepstral coefficients and the first- and second-order difference Mel-frequency cepstral coefficients are employed to extract the features of the signals. The adaptive Hemming window length is a major advantage of the methodology. The S1-S2 interval determines the adaptive length. Heart sounds are divided into normal and abnormal through the improved hidden Markov model and Baum-Welch and Viterbi algorithms. The proposed framework is evaluated using a number of datasets under various scenarios.


Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 181
Author(s):  
Chen-Jun She ◽  
Xie-Feng Cheng ◽  
Kai Wang

In this paper, the graphic representation method is used to study the multiple characteristics of heart sounds from a resting state to a state of motion based on single- and four-channel heart-sound signals. Based on the concept of integration, we explore the representation method of heart sound and blood pressure during motion. To develop a single- and four-channel heart-sound collector, we propose new concepts such as a sound-direction vector of heart sound, a motion–response curve of heart sound, the difference value, and a state-change-trend diagram. Based on the acoustic principle, the reasons for the differences between multiple-channel heart-sound signals are analyzed. Through a comparative analysis of four-channel motion and resting-heart sounds, from a resting state to a state of motion, the maximum and minimum similarity distances in the corresponding state-change-trend graphs were found to be 0.0038 and 0.0006, respectively. In addition, we provide several characteristic parameters that are both sensitive (such as heart sound amplitude, blood pressure, systolic duration, and diastolic duration) and insensitive (such as sound-direction vector, state-change-trend diagram, and difference value) to motion, thus providing a new technique for the diverse analysis of heart sounds in motion.


Author(s):  
Muhammed Telceken ◽  
Yakup Kutlu

Heart sounds are important data that reflect the state of the heart. It is possible to prevent larger problems that may occur with early diagnosis of abnormalities in heart sounds. Therefore, in this study, the detection of abnormalities in heart sounds has been studied. In order to detect abnormalities in heart sounds, the heartbeat-sounds data set obtained free of charge from the kaggle.com website was examined. Mel frequency cepstral coefficients (MFCCs) were used in the selection of the characteristics of the sounds. Parameters such as the number of filters to be applied for MFCCs, the number of attributes to be extracted are examined separately with different values. The classification performance of heart sounds with feature matrices extracted in different parameters of MFCCs with K-nearest neighbor algorithm was investigated. The classification performance of different feature extractions was compared and the best case was tried to be determined. Two different records that make up the data set were examined separately as normal and abnormal. Then, the new data set obtained by combining the two records was examined as normal and abnormal.


2021 ◽  
Vol 2 (4) ◽  
Author(s):  
H Makimoto ◽  
T Shiraga ◽  
B Kohlmann ◽  
C.-E Magnisali ◽  
R Schenk ◽  
...  

Abstract Background Aortic stenosis is still one of the major causes of sudden cardiac death in the elderly. Noninvasive screening for severe aortic valve stenosis (AS) may result in early cardiac diagnostic leading to an appropriate and timely medical intervention. Purpose The aims of this study were 1) to develop an artificial intelligence to detect severe AS based on heart sounds and 2) to build an application to screen patients using electronic stethoscope and smartphones, which will provide an efficient diagnostic workflow for screening as a complementary tool in daily clinical practice. Methods We enrolled 100 patients diagnosed with severe AS and 200 patients without severe AS (no echocardiographic sign of AS [n=100], mild AS [n=50], moderate AS [n=50]). The heart sounds were recorded in 4000 Hz waveform audio format at the following 3 sites of each patient; the 2nd intercostal right sternal border, the Erb's area and the apex. Each record was divided into multiple data of 4 seconds duration, which built 10800 sound records in total. We developed multiple convolutional neural networks (CNN) designed to recognize severe AS in heart sounds according to the recorded 3 sites. We adopted a stratified 4-fold cross-validation method by which the CNN was trained with 60% of the whole data, validated with 20% data and tested with the remaining 20% data not used during training and validation. As performance metrics we adopted the accuracy, F1 value and the area under the curve (AUC) calculated as the average of all cross-validation folds. For the smartphone application, we combined the best CNN-models from each recorded site for the best performance. Further 40 patients were newly enrolled for its clinical validation (no AS [n=10], mild AS [n=10], moderate AS [n=10], severe AS [n=10]). Results The accuracy, F1 value and AUC of each model were 88.9±5.7%, 0.888±0.006 and 0.953±0.008, respectively. The sensitivity and specificity were 87.9±2.2% and 89.9±2.4%. The recognition accuracy of moderate AS was significantly lower as compared to the other AS grades (moderate AS 74.1±6.1% vs no AS 98.0±1.4%, mild AS 97.6±1.2%, severe AS 87.9±2.2%, respectively, P<0.05). Our smartphone application showed a sensitivity of 100% (10/10), a specificity of 73.3% (22/30), and an accuracy of 80.0% (32/40), which implicated a good utility for screening. In the detailed analysis of 8 mistaken decisions, these were highly affected by the presence of severe mitral or tricuspid valve regurgitation despite of non-severe AS (7/8 [87.5%]). Conclusions This study demonstrated the promising possibility of an end-to-end screening for severe aortic valve stenosis using an electronic stethoscope and a smartphone application. This technology may improve the efficacy of daily medicine particularly where the human resource is limited or support a remote medical consultation. Further investigations are necessary to increase accuracy. Funding Acknowledgement Type of funding sources: None.


2021 ◽  
Vol 9 (24) ◽  
pp. 1752-1752
Author(s):  
Xin Zhou ◽  
Xuying Wang ◽  
Xianhong Li ◽  
Yao Zhang ◽  
Ying Liu ◽  
...  

2021 ◽  
Vol 12 ◽  
Author(s):  
Emilio Andreozzi ◽  
Gaetano D. Gargiulo ◽  
Daniele Esposito ◽  
Paolo Bifulco

The precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardiography (FCG) is a non-invasive technique that measures these vibrations via force sensing resistors (FSR). This study presents a new piezoelectric sensor able to record all heart vibrations simultaneously, as well as a respiration signal. The new sensor was compared to the FSR-based one to assess its suitability for FCG. An electrocardiogram (ECG) lead and a signal from an electro-resistive respiration band (ERB) were synchronously acquired as references on six healthy volunteers (4 males, 2 females) at rest. The raw signals from the piezoelectric and the FSR-based sensors turned out to be very similar. The raw signals were divided into four components: Forcerespirogram (FRG), Low-Frequency FCG (LF-FCG), High-Frequency FCG (HF-FCG) and heart sounds (HS-FCG). A beat-by-beat comparison of FCG and ECG signals was carried out by means of regression, correlation and Bland–Altman analyses, and similarly for respiration signals (FRG and ERB). The results showed that the infrasonic FCG components are strongly related to the cardiac cycle (R2 > 0.999, null bias and Limits of Agreement (LoA) of ± 4.9 ms for HF-FCG; R2 > 0.99, null bias and LoA of ± 26.9 ms for LF-FCG) and the FRG inter-breath intervals are consistent with ERB ones (R2 > 0.99, non-significant bias and LoA of ± 0.46 s). Furthermore, the piezoelectric sensor was tested against an accelerometer and an electronic stethoscope: synchronous acquisitions were performed to quantify the similarity between the signals. ECG-triggered ensemble averages (synchronized with R-peaks) of HF-FCG and SCG showed a correlation greater than 0.81, while those of HS-FCG and PCG scored a correlation greater than 0.85. The piezoelectric sensor demonstrated superior performances as compared to the FSR, providing more accurate, beat-by-beat measurements. This is the first time that a single piezoelectric sensor demonstrated the ability to simultaneously capture respiration, heart sounds, an SCG-like signal (i.e., HF-FCG) and the LF-FCG signal, which may provide information on ventricular emptying and filling events. According to these preliminary results the novel piezoelectric FCG sensor stands as a promising device for accurate, unobtrusive, long-term monitoring of cardiorespiratory functions and paves the way for a wide range of potential applications, both in the research and clinical fields. However, these results should be confirmed by further analyses on a larger cohort of subjects, possibly including also pathological patients.


Author(s):  
Nancy Jariwala ◽  
Sydney Czako ◽  
Lindsey Brenton ◽  
Audrey Doherty ◽  
Karandeep Singh ◽  
...  

2021 ◽  
Author(s):  
Ahmed Ali Dawud ◽  
Bheema Lingaiah ◽  
Towfik Jemal

Abstract Background: Now a day, cardiovascular diseases have been a major cause of death in the world. The heart sound is still the primary tool used for screening and diagnosing many pathological conditions of the human heart. The abnormality in the heart sounds starts appearing much earlier than the symptoms of the disease. In this study, the Phonocardiography signal has been studied and classified into three classes, namely normal signal, murmur signal and extra sound signal. A total of 15 features from different domains have been extracted and then reduced to 7 features. The features have been selected on the basis of correlation based feature selection technique. The selected features are used to classify the signal into the predefined classes using multi- class SVM classifier. The performance of the proposed denoising algorithm is evaluated using the signal to noise ratio, percentage root means square difference, and root mean square error. For this work a publically available database for researchers, Partnership Among South Carolina Academic Libraries (PASCAL) and MATLAB 2018a was used to develop the proposed algorithm.Results: Our experimental result shows that the 4th level of decomposition for the Db10 wavelets shows the highest SNR values when using the soft and hard thresholding. The overall accuracy, Sensitivity and Specificity of the developed algorithm is 97.96%, 97.92 % and of 98.0% respectively.Conclusion: even if the proposed algorithm is useful for murmur detection mainly valve-related diseases and the efficiency of the proposed study is increased, future work will intend to generalize the algorithm by using hybrid classifiers on a larger dataset. Since all experiments used the PASCAL datasets, additional experiments will be needed using new datasets to be implemented using the latest mobile phones which can work as an electronic stethoscope or phonocardiogram. In addition, the case of continuous murmur and types of murmur has been included for classification in further studies.


Informatics ◽  
2021 ◽  
Vol 8 (4) ◽  
pp. 73
Author(s):  
Ivo Sérgio Guimarães Brites ◽  
Lídia Martins da Silva ◽  
Jorge Luis Victória Barbosa ◽  
Sandro José Rigo ◽  
Sérgio Duarte Correia ◽  
...  

This article presents a systematic mapping study dedicated to conduct a literature review on machine learning and IoT applied in the identification of diseases through heart sounds. This research was conducted between January 2010 and July 2021, considering IEEE Xplore, PubMed Central, ACM Digital Library, JMIR—Journal of Medical Internet Research, Springer Library, and Science Direct. The initial search resulted in 4372 papers, and after applying the inclusion and exclusion criteria, 58 papers were selected for full reading to answer the research questions. The main results are: of the 58 articles selected, 46 (79.31%) mention heart rate observation methods with wearable sensors and digital stethoscopes, and 34 (58.62%) mention care with machine learning algorithms. The analysis of the studies based on the bibliometric network generated by the VOSviewer showed in 13 studies (22.41%) a trend related to the use of intelligent services in the prediction of diagnoses related to cardiovascular disorders.


Sign in / Sign up

Export Citation Format

Share Document