waveguide grating
Recently Published Documents


TOTAL DOCUMENTS

1416
(FIVE YEARS 119)

H-INDEX

48
(FIVE YEARS 4)

2021 ◽  
Vol 29 (22) ◽  
pp. 35261
Author(s):  
Jaegyu Park ◽  
Jiho Joo ◽  
Myung-Joon Kwack ◽  
Gyungock Kim ◽  
Sang-Pil Han ◽  
...  

Crystals ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 1170
Author(s):  
Yannong Luo ◽  
Renyou Ge ◽  
Haozhi Luo ◽  
Meiyan Wu ◽  
Lidan Zhou ◽  
...  

We demonstrate a polarization splitter rotator (PSR) based on multimode waveguide grating (MWG) on a silicon-on-insulator (SOI) platform. Bloch mode hybridization in mini-stopband is exploited to achieve high polarization conversion efficiency. The fabricated device yields a high extinction ratio of > 53 dB and > 31 dB, low crosstalk of < −26.4 dB and < −40 dB for the injected TE0 and TM0 mode, with average insertion loss of 1.2 dB and 1.5 dB in the wavelength regime 1552 nm–1562 nm. Such a device shows great design flexibility and an easy fabrication process, serving as a good candidate in integrated polarization diversity circuits, especially for applications requiring spectra manipulation. Additionally, the polarization conversion approach provides opportunities to develop novel polarization management devices.


Sensors ◽  
2021 ◽  
Vol 21 (18) ◽  
pp. 6214
Author(s):  
Vincenzo Romano Marrazzo ◽  
Francesco Fienga ◽  
Michele Riccio ◽  
Andrea Irace ◽  
Giovanni Breglio

In this manuscript, an optically passive fiber Bragg grating (FBG) interrogation system able to perform high-frequency measurement is proposed. The idea is mainly based on the use of an arrayed waveguide grating (AWG) device which is used to discriminate the fiber optic sensor (FOS) wavelength encoded response under test in function of its output channels. As made clear by the theoretical model studied in the proposed manuscript, the Bragg wavelength shift can be detected as in linear dependence with the proposed interrogation function which changes with the voltage produced by two (or more) adjacent AWG output channels. To prove the feasibility of the system, some experimental analyses are conducted with a custom electrical module characterized by high-speed and low-noise operational amplifiers. As static measurements, three FBGs with different full width at half maximum (FWHM) have been monitored under wide-range wavelength variation; while, as dynamic measurement, one FBG, glued onto a metal plate, in order to sense the vibration at low and high frequency, was detected. The output signals have been processed by a digital acquisition (DAQ) board and a graphical user interface (GUI). The presented work highlights the characteristics of the proposed idea as competitor among the entire class of interrogation systems currently used. This is because here, the main device, that is the AWG, is passive and reliable, without the need to use modulation signals, or moving parts, that affect the speed of the system. In addition, the innovative multi-channel detection algorithm allows the use of any type of FOS without the need to have a perfectly match of spectra. Moreover, it is also characterized by a high dynamic range without loss of sensitivity.


2021 ◽  
Author(s):  
Jiaxin Chen ◽  
Wanxin Li ◽  
Jinzhao Wang ◽  
Jiewen Li ◽  
Weiming Yao ◽  
...  

2021 ◽  
Author(s):  
Abdelfettah Hadij-ElHouati ◽  
Alejandro Ortega-Moñux ◽  
J. Gonzalo Wangüemert-Pérez ◽  
Robert Halir ◽  
shurui wang ◽  
...  

Biosensors ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 264
Author(s):  
Chunxue Wang ◽  
Pengfei Yi ◽  
Jiang Li ◽  
Haibing Dong ◽  
Changming Chen ◽  
...  

In this work, we successfully developed a fluorinated cross-linked polymer Bragg waveguide grating-based optical biosensor to detect effective drug concentrations of ginkgolide A for the inhibition of pulmonary microvascular endothelial cell (PMVEC) apoptosis. Fluorinated photosensitive polymer SU-8 (FSU-8) as the sensing core layer and polymethyl methacrylate (PMMA) as the sensing window cladding were synthesized. The effective drug concentration range (5–10 µg/mL) of ginkgolide A for inhibition of PMVEC apoptosis was analyzed and obtained by pharmacological studies. The structure of the device was optimized to be designed and fabricated by direct UV writing technology. The properties of the biosensor were simulated with various refractive indices of different drug concentrations. The actual sensitivity of the biosensor was measured as 1606.2 nm/RIU. The resolution and detection limit were characterized as 0.05 nm and 3 × 10−5 RIU, respectively. The technique is suitable for safe and accurate detection of effective organic drug dosages of Chinese herbal ingredients.


2021 ◽  
Vol 118 ◽  
pp. 111229
Author(s):  
Sipan Yang ◽  
Jinbin Xu ◽  
Yaqian Li ◽  
Liying Wu ◽  
Xueling Quan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document