post market surveillance
Recently Published Documents


TOTAL DOCUMENTS

79
(FIVE YEARS 33)

H-INDEX

8
(FIVE YEARS 1)

2021 ◽  
pp. 152660282110677
Author(s):  
Osamu Iida ◽  
Takao Ohki ◽  
Yoshimitsu Soga ◽  
Nobuhiro Suematsu ◽  
Tatsuya Nakama ◽  
...  

Purpose: To assess the midterm safety and effectiveness of the Gore® Viabahn® Endoprosthesis as treatment for symptomatic peripheral arterial disease (PAD) in the superficial femoral arteries (SFA). Materials and Methods: A prospective, multicenter, post-market surveillance study was conducted in Japan. Patients with symptomatic SFA lesions ≥ 10 cm and reference vessel diameters ranging from 4.0 to 7.5 mm were eligible for enrollment; patients with traumatic or iatrogenic vessel injury in the thoracic, abdominal, or pelvic arteries were excluded. Outcomes evaluated at 12 months were primary patency (PP), primary-assisted patency (PAP), secondary patency (SP), freedom from target lesion revascularization (fTLR), occurrence of device- or procedure-related serious adverse events (SAEs), and stent fractures. Results: From August 2016 to May 2017, 321 patients were enrolled at 64 Japanese sites (mean age, 73.9±8.7 years; 77.3% male). Hypertension, diabetes, and end stage renal disease were present in 84.4%, 54.8%, and 23.1% of patients, respectively. Mean lesion length was 23.6 cm±6.6 cm, with lesions ≥ 15 cm in 271 patients (84.4%). TASC C/D lesions accounted for 86.6% (39.1% TASC C, 47.5% TASC D); 26.5% had critical limb ischemia. Baseline ABI was 0.60±0.16. A total of 562 devices were implanted in 324 limbs, with a majority of patients (68.8%) receiving 2 stents. Through 12 months, 92.1% of patients were evaluable. Kaplan-Meier-estimated PP, PAP, and SP at 12 months was 85.6%, 91.7%, and 94.8%, respectively. Twelve-month fTLR was 92.3%. Mean change in ABI at 12 months was 0.343±0.21; mean improvement in Rutherford class was 2.5. Device- or procedure-related SAEs occurred in 3.1% through 30 days, with a majority of early SAEs consisting of access complications. Through 12 months, a cumulative 10.6% had device- or procedure-related SAEs, with the most common being device occlusions in 4.0%. Lower limb amputation occurred in 0.9% and was related to pre-existing ulceration or gangrene in all 3 cases. No stent fractures were observed at 12-month x-ray evaluation. Conclusion: In a real-world Japanese patient population characterized by long SFA lesions and complex PAD, the Viabahn endoprosthesis was associated with excellent patency rates through 12 months and an acceptable safety profile.


Author(s):  
Kennedy Abuga ◽  
Nasser Nyamweya ◽  
Obed King’ondu

The emergence of the COVID-19 pandemic has propelled the use of alcohol-based hand sanitizers to the fore as a SARS-CoV-2 control measure. To be effective these products must comply with relevant quality parameters such as alcohol concentration, methanol limits and purity. The current study was designed to determine the quality of alcohol-based hand sanitizer products in the Nairobi metropolitan area. For this purpose, 74 commercially marketed samples were collected and subjected to analysis by gas chromatography. Only three samples (4.1%) complied with the regulatory specifications for alcohol content, methanol limits and pH. Five samples (6.8%) complied with the specification for alcohol content but did not meet methanol or pH limits. A total of 44 (59.5%) samples had methanol levels that exceeded threshold limits. Eleven samples (14.9%) were found with methanol substitution (i.e., methanol, instead of ethanol or isopropanol, was the main alcohol component). The results show that users of alcohol-based hand sanitizers are being exposed to substandard and falsified products which in addition to being non-efficacious pose harm due to unacceptable levels of toxic impurities. Regular, routine post-market surveillance is needed to prevent such products from reaching the market.


2021 ◽  
pp. 193229682110423
Author(s):  
Stuart Phillips ◽  
Steven Setford ◽  
Mike Grady ◽  
Zuifang Liu ◽  
Hilary Cameron

Background Regulations and industry guidance relating to testing for interference in blood glucose monitoring (BGM) systems continue to focus on in vitro laboratory bench tests. Post-market surveillance (PMS) in a clinical setting allows for BGM accuracy assessments to evaluate the impact of real-world exposure to polypharmacy in people with diabetes. This study evaluated the OneTouch Select Plus® BGM test-strip accuracy with respect to polypharmacy using a clinical registry dataset. Methods Medication profiles were analysed for 1023 subjects (425 with type 1 (T1D) and 598 with type 2 diabetes (T2D)) attending 3 UK hospitals. Blood samples were analysed to determine clinical accuracy of the BGM test-strip against a laboratory comparator. Results 538 different medications (48 diabetes and 490 non-diabetes) were recorded across the 1023 subjects. Patients took on average 6.9 ( n = 1-36) individual medications and 4.1 ( n = 1-13) unique medication classes. Clinical accuracy to EN ISO 15197:2015 criteria were met irrespective of increasing average number of individual medications, categorized from 1-3, 4-6, 7-9, 10-12 and >12 taken per subject (97.7%, 97.7%, 97.8%, 97.8%, and 98.4%, respectively). Clinical accuracy criteria were met across 15 classes of medication using the combined dataset (97.9%; 29784/30433). Surveillance Error Grid (SEG) analysis showed 98.7% (29959/30368) of readings presented no clinical risk. No individual class or combination of medication classes impacted clinical accuracy of the BGM test-strip. Conclusions Clinical performance for the test strip under assessment demonstrated no evidence of interference from over 500 prescription medications, with clinical accuracy maintained across a range of polypharmacy conditions in people with diabetes.


2021 ◽  
pp. 193229682110394 ◽  
Author(s):  
Steven Setford ◽  
Zuifang Liu ◽  
David McColl ◽  
Stuart Phillips ◽  
Hilary Cameron ◽  
...  

Background: On-going manufacturer-led post-market surveillance (PMS), assessing the clinical accuracy of blood glucose monitoring (BGM) systems, is critical to substantiate the performance of such products for people with diabetes. Materials and Methods: Batches of Verio test-strip product were randomly and routinely selected over the period from launch of an improved-algorithm product to reporting date and sent to 3 clinic sites for clinician-led accuracy assessment. Accuracy is reported as per recently adopted FDA guidance for BGM systems, EN ISO 15197:2015 and MARD/MAD (Mean absolute relative difference/Mean absolute difference). Results: Thirty-three individual test-strip batches were evaluated corresponding to 506 unique donors. Accuracy performance - FDA: 98.9% of values within ±15% of comparator; ISO: 99.0% within ±15 mg/dL or ±15% at <100 mg/dL (<5.55 mmol/L) or ≥100 mg/dL (≥5.55 mmol/L) glucose, respectively. Overall MARD was 4.19% with a MARD range of 3.54%-5.73% across all test strip batches. Conclusions: This post-market surveillance program demonstrates the new BGM system consistently meets measures of clinical accuracy specified by regulators. This program supports a growing demand by regulators for real-world evidence demonstrating consistent in-market product efficacy as opposed to the current largely passive approach that relies on assessment of reports filed by device users.


2021 ◽  
Vol 2 (8) ◽  
pp. 599-610
Author(s):  
Harry Hothi ◽  
Sean Bergiers ◽  
Johann Henckel ◽  
Alexis D. Iliadis ◽  
William David Goodier ◽  
...  

Aims The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. Methods We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions. Results All nails were removed at the end of treatment, having achieved their intended lengthening (20 mm to 65 mm) and after regenerate consolidation. All nails had evidence of corrosion localized to the screw holes and the extendable junctions; corrosion was graded as moderate at the junction of one nail and severe at the junctions of five nails. EDS analysis showed surface deposits to be chromium rich. Plain radiographs showed cortical thickening and osteolysis around the junction of six nails, corresponding to the same nails with moderate – severe junction corrosion. Conclusion We found, in fully united bones, evidence of cortical thickening and osteolysis that appeared to be associated with corrosion at the extendable junction; when corrosion was present, cortical thickening was adjacent to this junction. Further work, with greater numbers of retrievals, is required to fully understand this association between corrosion and bony changes, and the influencing surgeon, implant, and patient factors involved. Cite this article: Bone Jt Open 2021;2(8):599–610.