automated breast volume scanner
Recently Published Documents


TOTAL DOCUMENTS

50
(FIVE YEARS 8)

H-INDEX

12
(FIVE YEARS 0)

Author(s):  
Yingchun Liu ◽  
Lin Chen ◽  
Jia Zhan ◽  
Xuehong Diao ◽  
Yun Pang ◽  
...  

Objective: To explore inter-observer agreement on the evaluation of automated breast volume scanner (ABVS) for breast masses. Methods: A total of 846 breast masses in 630 patients underwent ABVS examinations. The imaging data were independently interpreted by senior and junior radiologists regarding the mass size ([Formula: see text][Formula: see text]cm, [Formula: see text][Formula: see text]cm and total). We assessed inter-observer agreement of BI-RADS lexicons, unique descriptors of ABVS coronal planes. Using BI-RADS 3 or 4a as a cutoff value, the diagnostic performances for 331 masses with pathological results in 253 patients were assessed. Results: The overall agreements were substantial for BI-RADS lexicons ([Formula: see text]–0.779) and the characteristics on the coronal plane of ABVS ([Formula: see text]), except for associated features ([Formula: see text]). However, the overall agreement was moderate for orientation ([Formula: see text]) for the masses [Formula: see text][Formula: see text]cm. The agreements were substantial to be perfect for categories 2, 3, 4, 5 and overall ([Formula: see text]–0.918). However, the agreements were moderate to substantial for categories 4a ([Formula: see text]), 4b ([Formula: see text]), and 4c ([Formula: see text]), except for category 4b of the masses [Formula: see text][Formula: see text]cm ([Formula: see text]). Moreover, for radiologists 1 and 2, there were no significant differences in sensitivity, specificity, accuracy, positive and negative predictive values with BI-RADS 3 or 4a as a cutoff value ([Formula: see text] for all). Conclusion: ABVS is a reliable imaging modality for the assessment of breast masses with good inter-observer agreement.


Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 172
Author(s):  
Shi-Jie Wang ◽  
Hua-Qing Liu ◽  
Tao Yang ◽  
Ming-Quan Huang ◽  
Bo-Wen Zheng ◽  
...  

Improving the assessment of breast imaging reporting and data system (BI-RADS) 4 lesions and reducing unnecessary biopsies are urgent clinical issues. In this prospective study, a radiomic nomogram based on the automated breast volume scanner (ABVS) was constructed to identify benign and malignant BI-RADS 4 lesions and evaluate its value in reducing unnecessary biopsies. A total of 223 histologically confirmed BI-RADS 4 lesions were enrolled and assigned to the training and validation cohorts. A radiomic score was generated from the axial, sagittal, and coronal ABVS images. Combining the radiomic score and clinical-ultrasound factors, a radiomic nomogram was developed by multivariate logistic regression analysis. The nomogram integrating the radiomic score, lesion size, and BI-RADS 4 subcategories showed good discrimination between malignant and benign BI-RADS 4 lesions in the training (AUC, 0.959) and validation (AUC, 0.925) cohorts. Moreover, 42.5% of unnecessary biopsies would be reduced by using the nomogram, but nine (4%) malignant BI-RADS 4 lesions were unfortunately missed, of which 4A (77.8%) and small-sized (<10 mm) lesions (66.7%) accounted for the majority. The ABVS radiomics nomogram may be a potential tool to reduce unnecessary biopsies of BI-RADS 4 lesions, but its ability to detect small BI-RADS 4A lesions needs to be improved.


2020 ◽  
Vol 58 (12) ◽  
pp. 3089-3099
Author(s):  
Alberto Casagrande ◽  
Francesco Fabris ◽  
Rossano Girometti

AbstractAgreement measures are useful tools to both compare different evaluations of the same diagnostic outcomes and validate new rating systems or devices. Cohen’s kappa (κ) certainly is the most popular agreement method between two raters, and proved its effectiveness in the last sixty years. In spite of that, this method suffers from some alleged issues, which have been highlighted since the 1970s; moreover, its value is strongly dependent on the prevalence of the disease in the considered sample. This work introduces a new agreement index, the informational agreement (IA), which seems to avoid some of Cohen’s kappa’s flaws, and separates the contribution of the prevalence from the nucleus of agreement. These goals are achieved by modelling the agreement—in both dichotomous and multivalue ordered-categorical cases—as the information shared between two raters through the virtual diagnostic channel connecting them: the more information exchanged between the raters, the higher their agreement. In order to test its fair behaviour and the effectiveness of the method, IA has been tested on some cases known to be problematic for κ, in the machine learning context and in a clinical scenario to compare ultrasound (US) and automated breast volume scanner (ABVS) in the setting of breast cancer imaging.


Gland Surgery ◽  
2019 ◽  
Vol 8 (6) ◽  
pp. 698-711
Author(s):  
Xiaohui Zhang ◽  
Juan Chen ◽  
Yidong Zhou ◽  
Feng Mao ◽  
Yan Lin ◽  
...  