component orientation
Recently Published Documents


TOTAL DOCUMENTS

61
(FIVE YEARS 7)

H-INDEX

15
(FIVE YEARS 2)

Author(s):  
Joost H. J. van Erp ◽  
Thom E. Snijders ◽  
Harrie Weinans ◽  
René M. Castelein ◽  
Tom P. C. Schlösser ◽  
...  

Abstract Introduction Dislocation remains a major complication in total hip arthroplasty (THA), in which femoral component orientation is considered a key parameter. New imaging modalities and definitions on femoral component orientation have been introduced, describing orientation in different planes. This study aims to systematically review the relevance of the different orientation parameters on implant stability. Methods A systematic review was performed according to the PRISMA guidelines to identify articles in the PubMed and EMBASE databases that study the relation between any femoral component orientation parameters and implant stability in primary THA. Results After screening for inclusion and exclusion criteria and quality assessment, nine articles were included. Definitions to describe the femoral component orientation and methodologies to assess its relevance for implant stability differed greatly, with lack of consensus. Seven retrospective case–control studies reported on the relevance of the transversal plane orientation: Low femoral- or low combined femoral and acetabular anteversion was statistical significantly related with more posterior dislocations, and high femoral- or combined femoral and acetabular anteversion with anterior dislocations in two studies. There were insufficient data on sagittal and coronal component orientation in relation to implant stability. Conclusion Because of incomparable definitions, limited quality and heterogeneity in methodology of the included studies, there is only weak evidence that the degree of transverse component version is related with implant stability in primary THA. Recommendations about the optimal orientation of the femoral component in all three anatomical planes cannot be provided. Future studies should uniformly define the three-dimensional orientation of the femoral component and systematically describe implant stability.


2020 ◽  
Vol 5 (12) ◽  
pp. 845-855
Author(s):  
Maria Moralidou ◽  
Anna Di Laura ◽  
Johann Henckel ◽  
Harry Hothi ◽  
Alister J. Hart

Three-dimensional (3D) pre-operative planning in total hip arthroplasty (THA) is being recognized as a useful tool in planning elective surgery, and as crucial to define the optimal component size, position and orientation. The aim of this study was to systematically review the existing literature for the use of 3D pre-operative planning in primary THA. A systematic literature search was performed using keywords, through PubMed, Scopus and Google Scholar, to retrieve all publications documenting the use of 3D planning in primary THA. We focussed on (1) the accuracy of implant sizing, restoration of hip biomechanics and component orientation; (2) the benefits and barriers of this tool; and (3) current gaps in literature and clinical practice. Clinical studies have highlighted the accuracy of 3D pre-operative planning in predicting the optimal component size and orientation in primary THAs. Component size planning accuracy ranged between 34–100% and 41–100% for the stem and cup respectively. The absolute, average difference between planned and achieved values of leg length, offset, centre of rotation, stem version, cup version, inclination and abduction were 1 mm, 1 mm, 2 mm, 4°, 7°, 0.5° and 4° respectively. Benefits include 3D representation of the human anatomy for precise sizing and surgical execution. Barriers include increased radiation dose, learning curve and cost. Long-term evidence investigating this technology is limited. Emphasis should be placed on understanding the health economics of an optimized implant inventory as well as long-term clinical outcomes. Cite this article: EFORT Open Rev 2020;5:845-855. DOI: 10.1302/2058-5241.5.200046


2020 ◽  
Vol 9 (7) ◽  
pp. 360-367
Author(s):  
Shinya Kawahara ◽  
Toshihiko Hara ◽  
Taishi Sato ◽  
Kazuki Kitade ◽  
Takeshi Shimoto ◽  
...  

Aims Appropriate acetabular component placement has been proposed for prevention of postoperative dislocation in total hip arthroplasty (THA). Manual placements often cause outliers in spite of attempts to insert the component within the intended safe zone; therefore, some surgeons routinely evaluate intraoperative pelvic radiographs to exclude excessive acetabular component malposition. However, their evaluation is often ambiguous in case of the tilted or rotated pelvic position. The purpose of this study was to develop the computational analysis to digitalize the acetabular component orientation regardless of the pelvic tilt or rotation. Methods Intraoperative pelvic radiographs of 50 patients who underwent THA were collected retrospectively. The 3D pelvic bone model and the acetabular component were image-matched to the intraoperative pelvic radiograph. The radiological anteversion (RA) and radiological inclination (RI) of the acetabular component were calculated and those measurement errors from the postoperative CT data were compared relative to those of the 2D measurements. In addition, the intra- and interobserver differences of the image-matching analysis were evaluated. Results Mean measurement errors of the image-matching analyses were significantly small (2.5° (SD 1.4°) and 0.1° (SD 0.9°) in the RA and RI, respectively) relative to those of the 2D measurements. Intra- and interobserver differences were similarly small from the clinical perspective. Conclusion We have developed a computational analysis of acetabular component orientation using an image-matching technique with small measurement errors compared to visual evaluations regardless of the pelvic tilt or rotation. Cite this article: Bone Joint Res 2020;9(7):360–367.


2019 ◽  
Vol 101-B (12) ◽  
pp. 1585-1592 ◽  
Author(s):  
Kartik Logishetty ◽  
Branavan Rudran ◽  
Justin P. Cobb

Aims Arthroplasty skills need to be acquired safely during training, yet operative experience is increasingly hard to acquire by trainees. Virtual reality (VR) training using headsets and motion-tracked controllers can simulate complex open procedures in a fully immersive operating theatre. The present study aimed to determine if trainees trained using VR perform better than those using conventional preparation for performing total hip arthroplasty (THA). Patients and Methods A total of 24 surgical trainees (seven female, 17 male; mean age 29 years (28 to 31)) volunteered to participate in this observer-blinded 1:1 randomized controlled trial. They had no prior experience of anterior approach THA. Of these 24 trainees, 12 completed a six-week VR training programme in a simulation laboratory, while the other 12 received only conventional preparatory materials for learning THA. All trainees then performed a cadaveric THA, assessed independently by two hip surgeons. The primary outcome was technical and non-technical surgical performance measured by a THA-specific procedure-based assessment (PBA). Secondary outcomes were step completion measured by a task-specific checklist, error in acetabular component orientation, and procedure duration. Results VR-trained surgeons performed at a higher level than controls, with a median PBA of Level 3a (procedure performed with minimal guidance or intervention) versus Level 2a (guidance required for most/all of the procedure or part performed). VR-trained surgeons completed 33% more key steps than controls (mean 22 (sd 3) vs 12 (sd 3)), were 12° more accurate in component orientation (mean error 4° (sd 6°) vs 16° (sd 17°)), and were 18% faster (mean 42 minutes (sd 7) vs 51 minutes (sd 9)). Conclusion Procedural knowledge and psychomotor skills for THA learned in VR were transferred to cadaveric performance. Basic preparatory materials had limited value for trainees learning a new technique. VR training advanced trainees further up the learning curve, enabling highly precise component orientation and more efficient surgery. VR could augment traditional surgical training to improve how surgeons learn complex open procedures. Cite this article: Bone Joint J 2019;101-B:1585–1592


2018 ◽  
Vol 100-B (10) ◽  
pp. 1280-1288 ◽  
Author(s):  
G. Grammatopoulos ◽  
W. Gofton ◽  
M. Cochran ◽  
J. Dobransky ◽  
A. Carli ◽  
...  

Aims This study aims to: determine the difference in pelvic position that occurs between surgery and radiographic, supine, postoperative assessment; examine how the difference in pelvic position influences subsequent component orientation; and establish whether differences in pelvic position, and thereafter component orientation, exist between total hip arthroplasties (THAs) performed in the supine versus the lateral decubitus positions. Patients and Methods The intra- and postoperative anteroposterior pelvic radiographs of 321 THAs were included; 167 were performed with the patient supine using the anterior approach and 154 were performed with the patient in the lateral decubitus using the posterior approach. The inclination and anteversion of the acetabular component was measured and the difference (Δ) between the intra- and postoperative radiographs was determined. The target zone was inclination/anteversion of 40°/20° (± 10°). Changes in the tilt, rotation, and obliquity of the pelvis on the intra- and postoperative radiographs were calculated from Δinclination/anteversion using the Levenberg–Marquardt algorithm. Results The mean postoperative inclination/anteversion was 40° (± 8°)/23° (± 9°) with Δinclination and/or Δanteversion > ± 10° in 74 (21%). Intraoperatively, the pelvis was anteriorly tilted by a mean of 4° (± 10°), internally rotated by a mean of 1° (± 10°) and adducted by a mean of 1° (± 5°). Having Δinclination and/or Δanteversion > ± 10° was associated with a 3.5 odds ratio of having the acetabular component outside the target zone. A greater proportion of THAs that were undertaken with the patient in the lateral decubitus position had Δinclination and/or Δanteversion > ± 10° (35.3%, 54/153) compared with those in the supine position (4.8%, 8/167; p < 0.001). A greater number of acetabular components were within the target zone in THAs undertaken with the patient in the supine position (72%, 120/167), compared with those in the lateral decubitus position (44%, 67/153; p < 0.001). Intraoperatively, the pelvis was more anteriorly tilted (p < 0.001) and more internally rotated (p = 0.04) when the patient was in the lateral decubitus position. Conclusion The pelvic position is more reliable when the patient is in the supine position, leading to more consistent orientation of the acetabular component. Significant differences in pelvic tilt and rotation are seen with the patient in the lateral decubitus position. Cite this article: Bone Joint J 2018;100-B:1280–8.


2018 ◽  
Vol 33 (8) ◽  
pp. 2652-2659.e3 ◽  
Author(s):  
Diana Widmer ◽  
Kilian Reising ◽  
Elmar Kotter ◽  
Peter Helwig

2017 ◽  
Vol 11 (1) ◽  
pp. 1432-1439 ◽  
Author(s):  
Yu Takeda ◽  
Shigeo Fukunishi ◽  
Shoji Nishio ◽  
Yuki Fujihara ◽  
Shinichi Yoshiya

Purpose: The purpose of this study was to examine the accuracy of implant orientation and leg length in total hip arthroplasty (THA) with an image-free navigation system based on a comparison of the intraoperative navigation and postoperative CT evaluations. Material and Methods: A consecutive series of 111 patients (118 hips) who underwent THA using the current version of the image-free navigation system constituted the basic study population. Subsequently, a total of 101 patients (108 hips) meeting the inclusion and exclusion criteria were selected as study subjects for the analysis. THA was performed using an image-free navigation system that was capable of adjusting both the prosthetic position and leg length. Postoperative CT examination was performed for all study subjects, and the prosthetic position and leg length were measured on CT images using the image analysis software. Subsequently, the intraoperative navigation results and the corresponding values obtained from the postoperative CT measurements were compared to test the accuracy of the navigation system. Results: The average discrepancies between the intra- and postoperative assessments were 6.8°, 3.7°, and 5.7° for cup anteversion, cup inclination, and stem anteversion, respectively. The corresponding value in leg length averaged 4.1 mm. Conclusion: Average discrepancies between the intra- and postoperative measurements were less than 10° in all prosthetic alignment parameters and less than 5 mm in leg length. Intraoperative assessments with the use of the image-free navigation in THA could afford satisfactory result.


Sign in / Sign up

Export Citation Format

Share Document