electrode sensor
Recently Published Documents


TOTAL DOCUMENTS

145
(FIVE YEARS 50)

H-INDEX

19
(FIVE YEARS 7)

Polimery ◽  
2021 ◽  
Vol 66 (11-12) ◽  
pp. 589-601
Author(s):  
Sachin Kumar ◽  
Sushil K. Sindhu ◽  
Praveen Kumar ◽  
Amit Sharma ◽  
Suresh Sagadevan

Three different carbon paste (CP), silk-screen (SP) and poly (vinyl chloride) (PVC) modified electrodes were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCl (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium tetraphenylborate (NaTPB), phosphomolybdic acid (PMA), phosphotungstic acid (PTA), and ammonium reineckate (RN) as electroactive materials. All three electrodes gave fast, viable, and near-Nernstian linear responses over a relative wide concentration range that ranged from 1.010-6 to 1.010-2 mol / L AV-MOXH at 25° C with a monovalent cationic decrease. The sensors demonstrated a good discernment of AV-MOXH from numerous inorganic and organic compounds such as glucose, sucrose, Na+, Ca+, etc. Additionally, the isothermal coefficients along with selectivity coefficients were calculated. The modified Screen Printed Electrode sensor appeared to be highly sensitive for the determination of AV-MOXH. The electrode response was observed in pH range 2--6 for ISPE electrodes and IPVC electrodes and 3--7 for ICPE electrodes under various temperature conditions. The short response time, lifetime validity, recovery, and all the methods of validation such as limit of detection and limit of quantification were estimated. The potentiometric method turned out to be suitable for determining AV-MOXH in pharmacological formulations, and the findings obtained are comparable to the “HPLC official method” in terms of the agreement. As a result, the postulated potentiometric approach was verified in accordance with IUPAC guidelines.


Author(s):  
T.S. Sunil Kumar Naik ◽  
Arul Varman Kesavan ◽  
B.E. Kumara Swamy ◽  
Simranjeet Singh ◽  
Amith G. Anil ◽  
...  

2021 ◽  
Author(s):  
Li-pin Li ◽  
Peng-li Zhang ◽  
Xiao-yu Lei ◽  
Guo-chao Xu

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Hanyuan Zhang ◽  
Ying Gan ◽  
Shu Yang ◽  
Kuang Sheng ◽  
Ping Wang

AbstractThe AlGaN/GaN-based sensor is a promising POCT (point-of-care-testing) device featuring miniaturization, low cost, and high sensitivity. BNP is an effective protein biomarker for the early diagnosis of HF (heart failure). In this work, a novel AlGaN/GaN device with the Kelvin connection structure and the corresponding detection technique was proposed. This technique can effectively suppress the background noise and improve the SNR (signal-to-noise ratio). A BNP detection experiment was carried out to verify the effectiveness of this technique. It is shown that compared with that of the traditional detection method, the LOD (limit of detection) was improved from 0.47 ng/mL to 1.29 pg/mL. The BNP detection experiment was also carried out with a traditional electrochemical Au-electrode sensor with the same surface functionalization steps. The AlGaN/GaN sensor showed a better LOD than the Au-electrode sensor. Moreover, the influence of AlGaN/GaN sensor package on background noise was investigated with the mechanism of the noise source revealed. Finally, based on the optimized package, the optimal SNR quiescent operating point of the AlGaN/GaN sensor was determined. By biasing the sensor at the optimal quiescent operating point and immobilizing the magnetic beads with anti-BNP on the gate of the AlGaN/GaN sensor, the LOD for BNP detection was further improved to 0.097 pg/mL.


2021 ◽  
Vol 2 (2) ◽  
pp. 143-152
Author(s):  
Alexander K. Manstein ◽  
Pavel A. Sokolov

The paper presents the elements of the development of the hardware and software complex "Flow meter of mineralization of aqueous solutions", designed for the rapid assessment of salinity of solutions directly in metal pipelines, with a permanent installation of a two-electrode sensor in an explosive zone, at pressures up to 160 atm. and with side walls of the measuring cell made of steel.


Sign in / Sign up

Export Citation Format

Share Document