array electrode
Recently Published Documents


TOTAL DOCUMENTS

299
(FIVE YEARS 69)

H-INDEX

43
(FIVE YEARS 6)

Author(s):  
Aida Hejlskov Poulsen ◽  
Boudewijn van den Berg ◽  
Federico G Arguissain ◽  
Jenny Tigerholm ◽  
Jan R Buitenweg ◽  
...  

Abstract Objective Small area electrodes enable preferential activation of nociceptive fibers. It is debated, however, whether co-activation of large fibers still occurs for the existing electrode designs. Moreover, existing electrodes are limited to low stimulation intensities, for which behavioral and physiological responses may be considered less reliable. A recent optimization study showed that there is a potential for improving electrode performance and increase the range of possible stimulation intensities. Based on those results, the present study introduces and tests a novel planar concentric array electrode design for small fiber activation in healthy volunteers. Approach Volunteers received electrical stimulation with the planar concentric array electrode and a regular patch electrode. Perception thresholds were estimated at the beginning and the end of the experiment. Evoked cortical potentials were recorded in blocks of 30 stimuli. For the patch, stimulation intensity was set to two times perception threshold (PT), while three intensities, 2, 5, and 10 times PT, were applied with the planar concentric array electrode. Sensation quality, numerical-rating scores, and reaction times were obtained for each PT estimation and during each block of evoked potential recordings. Main results Stimulation with the patch electrode was characterized as dull, while stimulation with the planar concentric array electrode was characterized as sharp, with increased sharpness for increasing stimulus intensity. Likewise, NRS scores were higher for the planar concentric array electrode compared to the patch and increased with increasing stimulation intensity. Reaction times and ERP latencies were longer for the planar concentric array electrode compared to the patch. Significance The presented novel planar concentric array electrode is a small, non-invasive, and single-use electrode that has the potential to investigate small fiber neuropathy and pain mechanisms, as it is small fiber preferential for a wide range of stimulation intensities.


Author(s):  
Marco Vinicio Alban ◽  
Haechang Lee ◽  
Hanul Moon ◽  
Seunghyup Yoo

Abstract Thin dry electrodes are promising components in wearable healthcare devices. Assessing the condition of the human body by monitoring biopotentials facilitates the early diagnosis of diseases as well as their prevention, treatment, and therapy. Existing clinical-use electrodes have limited wearable-device usage because they use gels, require preparation steps, and are uncomfortable to wear. While dry electrodes can improve these issues and have demonstrated performance on par with gel-based electrodes, providing advantages in mobile and wearable applications; the materials and fabrication methods used are not yet at the level of disposable gel electrodes for low-cost mass manufacturing and wide adoption. Here, a low-cost manufacturing process for thin dry electrodes with a conductive micro-pyramidal array is presented for large-scale on-skin wearable applications. The electrode is fabricated using micromolding techniques in conjunction with solution processes in order to guarantee ease of fabrication, high device yield, and the possibility of mass production compatible with current semiconductor production processes. Fabricated using a conductive paste and an epoxy resin that are both biocompatible, the developed micro-pyramidal array electrode operates in a conformal, non-invasive manner, with low skin irritation, which ensures improved comfort for brief or extended use. The operation of the developed electrode was examined by analyzing electrode-skin-electrode impedance, electroencephalography, electrocardiography, and electromyography signals and comparing them with those measured simultaneously using gel electrodes.


Materials ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4514
Author(s):  
Chuan-Pei Lee ◽  
Bayu-Tri Murti ◽  
Po-Kang Yang ◽  
Francesca Rossi ◽  
Carlo Carraro ◽  
...  

A cobalt oxide (Co3O4)-decorated silicon carbide (SiC) nano-tree array (denoted as Co3O4/SiC NTA) electrode is synthesized, and it is investigated for the use in the micro-supercapacitor. Firstly, the well-standing SiC nanowires (NWs) are prepared by nickel (Ni)-catalyzed chemical vapor deposition (CVD) method, and then the thin layer of Co3O4 and the hierarchical Co3O4 nano-flower-clusters are, respectively fabricated on the side-walls and the top side of the SiC NWs via electrodeposition. The deposition of Co3O4 on the SiC NWs benefits for the charge transfer at the electrode/aqueous electrolyte interface due to its extremely hydrophilic surface characteristic after Co3O4 decoration. Furthermore, the Co3O4/SiC NTA electrode would possess a directional charge transport route along the nanowire length of SiC NWs owing to their well-standing architecture. By using the Co3O4/SiC NTA electrode for micro-supercapacitor, the areal capacitance obtained from cyclic voltammetry measurement reaches 845 mF cm−2 at a 10 mV s−1 scan rate. Finally, the capacitance durability is also evaluated by the cycling test of cyclic voltammetry at a high scan rate of 150 mV s−1 for 2000 cycles.


2021 ◽  
Vol 140 ◽  
pp. 111293
Author(s):  
Li Wang ◽  
Xiaowei Lv ◽  
Quanbing Liu ◽  
Ningyi Jiang ◽  
Lei Zhang ◽  
...  
Keyword(s):  

2021 ◽  
Author(s):  
Li-pin Li ◽  
Peng-li Zhang ◽  
Xiao-yu Lei ◽  
Guo-chao Xu

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Yue Hou ◽  
Zhaoyu Li ◽  
Ziyu Wang ◽  
Hongyu Yu

AbstractHighly reliable signal recording with low electrode-skin impedance makes the microneedle array electrode (MAE) a promising candidate for biosignal sensing. However, when used in long-term health monitoring for some incidental diseases, flexible microneedles with perfectly skin-tight fit substrates lead to sweat accumulation inside, which will not only affect the signal output but also trigger some skin allergic reactions. In this paper, a flexible MAE on a Miura-ori structured substrate is proposed and fabricated with two-directional in-plane bendability. The results from the comparison tests show enhanced performance in terms of (1) the device reliability by resisting peeling off of the metal layer from the substrate during the operation and (2) air ventilation, achieved from the air-circulating channels, to remove sweat. Bio-signal recordings of electrocardiography (ECG), as well as electromyography (EMG) of the biceps brachii, in both static and dynamic states, are successfully demonstrated with superior accuracy and long-term stability, demonstrating the great potential in health monitoring applications.