radiometer measurement
Recently Published Documents


TOTAL DOCUMENTS

16
(FIVE YEARS 2)

H-INDEX

4
(FIVE YEARS 0)

2020 ◽  
Vol 237 ◽  
pp. 02035
Author(s):  
Anatoli Chaikovsky ◽  
Andrey Bril ◽  
Oleg Dubovik ◽  
Anton Fedarenka ◽  
Philippe Goloub ◽  
...  

The paper presents the preliminary results of the lidar&radiometer measurement campaign (LRMC-2017), estimation of statistical relations between aerosol mode concentrations retrieved from CALIOP and ground-based lidar stations and case study of fire smoke events in the Eurasian regions using combined ground-based and space lidar and radiometer observations.


Author(s):  
Ichwan Syahrul Bahtiar ◽  
Andjar Pudji ◽  
I Dewa Gede Hari Wisana

The phototherapy is a device used in hyperbilirubinemia therapy by using blue light radiation with ranges between 425nm-475nm. The effectiveness of hyperbilirubinemia therapy depends on the amount of energy emitted by light which expressed in μW/cm2. The purpose of this study is to develop a low-cost and high accuracy Phototherapy radiometer. Measurement of blue light irradiance using the AS7262 sensor which can measure the irradiance of visible light with a wavelength of 450nm, 500nm, 550nm, 570nm, 600nm, 650nm with relative responsiveness of 1 time at each wavelength. SD card memory is used to save measurement data of irradiance so that it can be processed later. Based on the blue light irradiance data collected the smallest error value is 0,40% at a distance of 10cm while the biggest error value is 9,01%  at a distance of 30cm. After testing the entire system, the device can be used according to its function and purpose.


Solar Energy ◽  
2016 ◽  
Vol 139 ◽  
pp. 85-99 ◽  
Author(s):  
Miguel de Simón-Martín ◽  
Montserrat Díez-Mediavilla ◽  
Cristina Alonso-Tristán

2014 ◽  
Vol 140-141 ◽  
pp. 85-94 ◽  
Author(s):  
Guirong Xu ◽  
Randolph (Stick) Ware ◽  
Wengang Zhang ◽  
Guangliu Feng ◽  
Kewen Liao ◽  
...  

2011 ◽  
Vol 32 (24) ◽  
pp. 8899-8913 ◽  
Author(s):  
Ying Guo ◽  
Jiancheng Shi ◽  
Jinyang Du ◽  
Xiuli Fu

2007 ◽  
Vol 7 (4) ◽  
pp. 11561-11586 ◽  
Author(s):  
M. Toohey ◽  
B. M. Quine ◽  
K. Strong ◽  
P. F. Bernath ◽  
C. D. Boone ◽  
...  

Abstract. Low-resolution atmospheric thermal emission spectra collected by balloon-borne radiometers over the time span of 1990–2002 are used to retrieve vertical profiles of HNO3, CFC-11 and CFC-12 volume mixing ratios between approximately 10 and 35 km altitude. All of the data analyzed have been collected from launches from a Northern Hemisphere mid-latitude site, during late summer, when stratospheric dynamic variability is at a minimum. The retrieval technique incorporates detailed forward modeling of the instrument and the radiative properties of the atmosphere, and obtains a best fit between modeled and measured spectra through a combination of onion-peeling and global optimization steps. The retrieved HNO3 profiles are consistent over the 12-year period, and are consistent with recent measurements by the Atmospheric Chemistry Experiment-Fourier transform spectrometer satellite instrument. This suggests that, to within the errors of the 1990 measurements, there has been no significant change in the HNO3 summer mid-latitude profile.