dinitrogen monoxide
Recently Published Documents


TOTAL DOCUMENTS

53
(FIVE YEARS 0)

H-INDEX

8
(FIVE YEARS 0)

2018 ◽  
Vol 85 (12) ◽  
pp. 746-753
Author(s):  
Carlo Tiebe ◽  
Marc Detjens ◽  
Ulrich Banach ◽  
Thomas Hübert

Abstract Especially trace amounts of water vapour in gases can be reliably determined by coulometric trace humidity sensors. The principle of these sensors is based on water vapour absorption in a hygroscopic layer and its subsequent electrolytic decomposition. The calibration of sensors was performed in the humidity range, expressed as frost point temperature, from -30\hspace{0.1667em}^\circ \mathrm{C} to -80\hspace{0.1667em}^\circ \mathrm{C}. This range is equivalent to volume fractions smaller than 376 µL·L−1. Generated humidity was measured with coulometric sensors and a chilled dew point hygrometer that was used as reference. An empirical non-linear function was found between sensor signal and measured reference humidity. This function consists of two parameters with a measurement uncertainty. Both calibration parameters were checked by means of one-way analysis of variance. It showed that gas specific function can be used for humidity measurement in nitrogen, hydrogen, dinitrogen monoxide, compressed and synthetic air. It is possible to determine trace humidity in all tested gases with an expanded uncertainty less than 2.1 K (coverage factor k=2) regarding frost point temperature.


2018 ◽  
Vol 10 (1) ◽  
pp. 22-26
Author(s):  
Thanh Phong Nguyen ◽  
Carsten Cuhls

Methane (CH4) source of Greenhouse Gases should be considered; CH4 is formed by composting under anaerobic conditions. Using microbial Methane oxidation is a solution with low cost and effective. In this study, 27 bio-filters and 18 laboratory-scale bioreactors were used to investigate the potential for CH4 removal in biogas. The CH4, Dinitrogen monoxide (N2O) and Carbon dioxide (CO2) concentrations at the inlet and outlet of the air purifier were measured by gas chromatography. The results showed that the CH4 concentration decreased in experiments while the CO2 and N2O content increased in all experiments. An experiment was conducted with 1 kg of biofilter material with the input of 800 ppm CH4 contained in a 5-liter flask for 49 hours containing. The results also showed that the CH4 concentration decreased by 71% after 20 hours and N2O was formed in the reactor. Mê-tan (CH4) là nguồn khí gây nên hiệu ứng nhà kính cần được quan tâm, khí CH4 được sinh ra trong quá trình ủ vi sinh trong điều kiện kị khí. Một giải pháp với chi phí thấp là sử dụng vi sinh vật oxy hóa khí CH4 cố định trên giá thể là vật liệu sử dụng trong thiết bị lọc sinh học. Trong nghiên cứu này, 27 thiết bị lọc sinh học trên thực tế và 19 bình lọc tại phòng thí nghiệm đã được sử dụng nhằm mục đích khảo sát khả năng loại bỏ CH4 có trong khí sinh học. Nồng độ khí CH4, N2O và CO2 ở đầu vào và đầu ra bể lọc khí được đo đạc bằng phương pháp sắc ký khí. Kết quả cho thấy nồng độ khí CH4 giảm sau khi qua hệ thống lọc sinh học ở một số bình, trong khi nồng độ khí CO2 và N2O lại tăng lên ở tất cả các bình. Khi khảo sát khả năng oxi hóa CH4 ở nồng độ 800 ppm của 1kg vật liệu thiết bị lọc sinh học chứa trong bình phản ứng thể tích 5L với thời gian 49 giờ. Kết quả cho thấy nồng nồng độ CH4 giảm 71% sau 20 giờ. Tuy nhiên, N2O đã được ghi nhận có hình thành trong bình phản ứng đó.


2017 ◽  
Vol 90 (4) ◽  
pp. 582-587
Author(s):  
V. D. Voronchikhin ◽  
M. A. Khudolei ◽  
K. A. Dubkov ◽  
D. P. Ivanov ◽  
S. V. Semikolenov
Keyword(s):  

Author(s):  
E. Hirota ◽  
K. Kuchitsu ◽  
T. Steimle ◽  
J. Vogt ◽  
N. Vogt
Keyword(s):  

Author(s):  
E. Hirota ◽  
K. Kuchitsu ◽  
T. Steimle ◽  
J. Vogt ◽  
N. Vogt
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document