International Journal of Particle Therapy
Latest Publications


TOTAL DOCUMENTS

278
(FIVE YEARS 122)

H-INDEX

14
(FIVE YEARS 2)

Published By International Journal Of Particle Therapy

2331-5180

Author(s):  
Christopher M. Wright ◽  
Jonathan Baron ◽  
Daniel Y. Lee ◽  
Michele Kim ◽  
Andrew R. Barsky ◽  
...  

Abstract Purpose One significant advantage of proton therapy is its ability to improve normal tissue sparing and toxicity mitigation, which is relevant in the treatment of oropharyngeal squamous cell carcinoma (OPSCC). Here, we report our institutional experience and dosimetric results with adjuvant proton radiation therapy (PRT) versus intensity-modulated radiotherapy (IMRT) for Human Papilloma Virus (HPV)-associated OPSCC. Materials and Methods This was a retrospective, single institutional study of all patients treated with adjuvant PRT for HPV-associated OPSCC from 2015 to 2019. Each patient had a treatment-approved equivalent IMRT plan to serve as a reference. Endpoints included dosimetric outcomes to the organs at risk (OARs), local regional control (LRC), progression-free survival (PFS), and overall survival (OS). Descriptive statistics, a 2-tailed paired t test for dosimetric comparisons, and the Kaplan-Meier method for disease outcomes were used. Results Fifty-three patients were identified. Doses delivered to OARs compared favorably for PRT versus IMRT, particularly for the pharyngeal constrictors, esophagus, larynx, oral cavity, and submandibular and parotid glands. The achieved normal tissue sparing did not negatively impact disease outcomes, with 2-year LRC, PFS, and OS of 97.0%, 90.3%, and 97.5%, respectively. Conclusion Our study suggests that meaningful normal tissue sparing in the postoperative setting is achievable with PRT, without impacting disease outcomes.


Author(s):  
Line Bjerregaard Stick ◽  
Maria Fuglsang Jensen ◽  
Søren M. Bentzen ◽  
Claus Kamby ◽  
Anni Young Lundgaard ◽  
...  

Abstract Purpose This study compares photon and proton therapy plans for patients with synchronous bilateral early breast cancer and estimates risks of early and late radiation-induced toxicities. Materials and Methods Twenty-four patients with synchronous bilateral early breast cancer receiving adjuvant radiation therapy using photons, 3-dimensional conformal radiation therapy or volumetric modulated arc therapy, were included and competing pencil beam scanning proton therapy plans were created. Risks of dermatitis, pneumonitis, acute esophageal toxicity, lung and breast fibrosis, hypothyroidism, secondary lung and esophageal cancer and coronary artery events were estimated using published dose-response relationships and normal tissue complication probability (NTCP) models. Results The primary clinical target volume V95% and/or nodal clinical target volume V90% were less than 95% in 17 photon therapy plans and none of the proton plans. Median NTCP of radiation dermatitis ≥ grade 2 was 18.3% (range, 5.4-41.7) with photon therapy and 58.4% (range, 31.4-69.7) with proton therapy. Median excess absolute risk (EAR) of secondary lung cancer at age 80 for current and former smokers was 4.8% (range, 0.0-17.0) using photons and 2.7% (range, 0.0-13.6) using protons. Median EAR of coronary event at age 80, assuming all patients have preexisting cardiac risk factors, was 1.0% (range, 0.0-5.6) with photons and 0.2% (range, 0.0-1.3) with protons. Conclusion Proton therapy plans improved target coverage and reduced risk of coronary artery event and secondary lung cancer while increasing the risk of radiation dermatitis.


Author(s):  
Andrew Johnson ◽  
Nicolas Depauw ◽  
Stephen Zieminski; ◽  
Rachel Jimenez

Abstract Introduction A subset of metastatic breast cancer patients present with oligometastatic disease involving the sternum. Given the proximity to traditional target structures, a proton radiation field can be expanded to include this region, providing definitive therapy for patients who are otherwise metastatic. We evaluated the feasibility and outcomes of a small series of patients who received comprehensive nodal irradiation inclusive of an isolated sternal metastasis using proton pencil beam scanning. Materials and Methods Four patients with a diagnosis of metastatic breast cancer with an isolated metastasis to the sternum received multimodality therapy with curative intent and then underwent adjuvant pencil beam scanning with definitive treatment to the sternum. Dosimetric parameters and treatment outcomes were evaluated. Results With respect to treatment coverage, proton therapy was able to deliver comprehensive target structure coverage while maintaining modest doses to the organs at risk compared with photon techniques. At a median follow-up of 28 months from diagnosis, none of the patients have experienced relapse within the radiation portal or developed additional sites of metastatic disease. Conclusion Pencil beam scanning for oligometastatic breast cancer with isolated sternal lesions appears feasible without undue normal tissue exposure. Current treatment outcomes appear promising.


Author(s):  
Alicia Bao ◽  
Andrew R. Barsky ◽  
Russell Maxwell ◽  
Justin E. Bekelman ◽  
Stefan Both ◽  
...  

Abstract Purpose Long-term data regarding the disease control outcomes of proton beam therapy (PBT) for patients with favorable risk intact prostate cancer (PC) are limited. Herein, we report our institution's long-term disease control outcomes in PC patients with clinically localized disease who received PBT as primary treatment. Methods One hundred sixty-six favorable risk PC patients who received definitive PBT to the prostate gland at our institution from 2010 to 2012 were retrospectively assessed. The outcomes studied were biochemical failure-free survival (BFFS), biochemical failure, local failure, regional failure, distant failure, PC-specific survival, and overall survival. Patterns of failure were also analyzed. Multivariate Cox proportional hazards modeling was used to estimate independent predictors of BFFS. Results The median length of follow-up was 8.3 years (range, 1.2–10.5 years). The majority of patients had low-risk disease (58%, n = 96), with a median age of 64 years at the onset of treatment. Of 166 treated men, 13 (7.8%), 8 (4.8%), 2 (1.2%) patient(s) experienced biochemical failure, local failure, regional failure, respectively. Regional failure was seen in an obturator lymph node in 1 patient and the external iliac lymph nodes in the other. None of the patients experienced distant failure. There were 5 (3.0%) deaths, none of which were due to PC. The 5- and 8-year BFFS rate were 97% and 92%, respectively. None of the clinical disease characteristics or treatment-related factors assessed were associated with BFFS on multivariate Cox proportional hazards modeling (all P > .05). Conclusion Disease control rates reported in our assessment of PBT were similar to those reported in previous clinically localized intact PC analyses, which used intensity-modulated radiotherapy, three-dimensional conformal radiotherapy, or radical prostatectomy as definitive therapy. In addition, BFFS rates were similar, if not improved, to previous PBT studies.


Author(s):  
Ashley Way ◽  
Savas Ozdemir ◽  
Barbara Berges ◽  
Nataliya Getman ◽  
Xiaoying Liang ◽  
...  

Abstract We present a case of recurrent pericardial effusion presenting during proton therapy in a 24-year-old female receiving mediastinal treatment for classical Hodgkin lymphoma. Pericardial effusion is typically considered an event accompanying lymphoma diagnosis or as a subacute or late effect of radiotherapy. Rarely has it been described as occurring during radiation treatment with photon-based radiotherapy, let alone proton therapy. It is unclear what underlying cause triggered recurrent effusion in this patient. Identifying and managing pericardial effusion during treatment delivery is important to consider as it may affect radiation dosimetry, particularly with proton therapy. Doing so will help ensure patients receive optimal treatment and minimize the risks of morbidity and mortality.


Author(s):  
Natalie Viscariello ◽  
Matthew D. Greer ◽  
Upendra Parvathaneni ◽  
Jay J. Liao ◽  
George E. Laramore ◽  
...  

Abstract Purpose Neutron therapy is a high linear energy transfer modality that is useful for the treatment of radioresistant head and neck (H&N) cancers. It has been limited to 3-dimensioanal conformal-based fast-neutron therapy (3DCNT), but recent technical advances have enabled the clinical implementation of intensity-modulated neutron therapy (IMNT). This study evaluated the comparative dosimetry of IMNT and 3DCNT plans for the treatment of H&N cancers. Materials and Methods Seven H&N IMNT plans were retrospectively created for patients previously treated with 3DCNT at the University of Washington (Seattle). A custom RayStation model with neutron-specific scattering kernels was used for inverse planning. Organ-at-risk (OAR) objectives from the original 3DCNT plan were initially used and were then systematically reduced to investigate the feasibility of improving a therapeutic ratio, defined as the ratio of the mean tumor to OAR dose. The IMNT and 3DCNT plan quality was evaluated using the therapeutic ratio, isodose contours, and dose volume histograms. Results When compared with the 3DCNT plans, IMNT reduces the OAR dose for the equivalent tumor coverage. Moreover, IMNT is most advantageous for OARs in close spatial proximity to the target. For the 7 patients with H&N cancers examined, the therapeutic ratio for IMNT increased by an average of 56% when compared with the 3DCNT. The maximum OAR dose was reduced by an average of 20.5% and 20.7% for the spinal cord and temporal lobe, respectively. The mean dose to the larynx decreased by an average of 80%. Conclusion The IMNT significantly decreases the OAR doses compared with 3DCNT and provides comparable tumor coverage. Improvements in the therapeutic ratio with IMNT are especially significant for dose-limiting OARs near tumor targets. Moreover, IMNT provides superior sparing of healthy tissues and creates significant new opportunities to improve the care of patients with H&N cancers treated with neutron therapy.


Author(s):  
Ronik S. Bhangoo ◽  
Molly M. Petersen ◽  
Gabriella F. Bulman ◽  
Carlos E. Vargas ◽  
Cameron S. Thorpe ◽  
...  

Abstract Purpose and Objectives With increasing use of hypofractionation and extreme hypofractionation for prostate cancer, rectal dose-volume histogram (DVH) parameters that apply across dose fractionations may be helpful for treatment planning in clinical practice. We present an exploratory analysis of biologically effective rectal dose (BED) and equivalent rectal dose in 2 Gy fractions (EQD2) for rectal bleeding in patients treated with proton therapy across dose fractionations. Materials and Methods From 2016 to 2018, 243 patients with prostate cancer were treated with definitive proton therapy. Rectal DVH parameters were obtained from treatment plans, and rectal bleeding events were recorded. The BED and EQD2 transformations were applied to each rectal DVH parameter. Univariate analysis using logistic regression was used to determine DVH parameters that were significant predictors of grade ≥ 2 rectal bleeding. Youden index was used to determine optimum cutoffs for clinically meaningful DVH constraints. Stepwise model-selection criteria were then applied to fit a “best” multivariate logistic model for predicting Common Terminology Criteria for Adverse Events grade ≥ 2 rectal bleeding. Results Conventional fractionation, hypofractionation, and extreme hypofractionation were prescribed to 117 (48%), 84 (34%), and 42 (17.3%) patients, respectively. With a median follow-up of 20 (2.5-40) months, 10 (4.1%) patients experienced rectal bleeding. On univariate analysis, multiple rectal DVH parameters were significantly associated with rectal bleeding across BED, EQD2, and nominal doses. The BED volume receiving 55 Gy > 13.91% was found to be statistically and clinically significant. The BED volume receiving 55 Gy remained statistically significant for an association with rectal bleeding in the multivariate model (odds ratio, 9.81; 95% confidence interval, 2.4-40.5; P = .002). Conclusion In patients undergoing definitive proton therapy for prostate cancer, dose to the rectum and volume of the rectum receiving the dose were significantly associated with rectal bleeding across conventional fractionation, hypofractionation, and extreme hypofractionation when using BED and EQD2 transformations.


2021 ◽  
Vol 8 (2) ◽  
pp. 41-50
Author(s):  
Richard Choo ◽  
David W. Hillman ◽  
Thomas Daniels ◽  
Carlos Vargas ◽  
Jean Claude Rwigema ◽  
...  

Abstract Purpose To assess acute gastrointestinal (GI) and genitourinary (GU) toxicities of intensity-modulated proton therapy (IMPT) targeting the prostate/seminal vesicles and pelvic lymph nodes for prostate cancer. Materials and Methods A prospective study (ClinicalTrials.gov: NCT02874014), evaluating moderately hypofractionated IMPT for high-risk or unfavorable intermediate-risk prostate cancer, accrued a target sample size of 56 patients. The prostate/seminal vesicles and pelvic lymph nodes were treated simultaneously with 6750 and 4500 centigray radiobiologic equivalent (cGyRBE), respectively, in 25 daily fractions. All received androgen-deprivation therapy. Acute GI and GU toxicities were prospectively assessed from 7 GI and 9 GU categories of the Common Terminology Criteria for Adverse Events (version 4), at baseline, weekly during radiotherapy, and 3-month after radiotherapy. Fisher exact tests were used for comparisons of categorical data. Results Median age was 75 years. Median follow-up was 25 months. Fifty-five patients were available for acute toxicity assessment. Sixty-two percent and 2%, respectively, experienced acute grade 1 and 2 GI toxicity. Grade 2 GI toxicity was proctitis. Sixty-five percent and 35%, respectively, had acute grade 1 and 2 GU toxicity. The 3 most frequent grade 2 GU toxicities were urinary frequency, urgency, and obstructive symptoms. None had acute grade ≥ 3 GI or GU toxicity. The presence of baseline GI and GU symptoms was associated with a greater likelihood of experiencing acute GI and GU toxicity, respectively. Of 45 patients with baseline GU symptoms, 44% experienced acute grade 2 GU toxicity, compared with only 10% among 10 with no baseline GU symptoms (P = 0.07). Although acute grade 1 and 2 GI and GU toxicities were common during radiotherapy, most resolved at 3 months after radiotherapy. Conclusion A moderately hypofractionated IMPT targeting the prostate/seminal vesicles and regional pelvic lymph nodes was well tolerated with no acute grade ≥ 3 GI or GU toxicity. Patients with baseline GU symptoms had a higher rate of acute grade 2 GU toxicity.


Author(s):  
Anissa Bey ◽  
Jiasen Ma ◽  
Keith M. Furutani ◽  
Michael G. Herman ◽  
Jedediah E. Johnson ◽  
...  

Abstract Purpose This article presents an in vivo imaging technique based on nuclear fragmentation of carbon ions in irradiated tissues for potential real-time monitoring of carbon-ion radiation therapy (CIRT) treatment delivery and quality assurance purposes in clinical settings. Materials and Methods A proof-of-concept imaging and monitoring system (IMS) was devised to implement the technique. Monte Carlo simulations were performed for a prospective pencil-beam scanning CIRT nozzle. The development IMS benchmark considered a 5×5-cm2 pixelated charged-particle detector stack positioned downstream from a target phantom and list-mode data acquisition. The abundance and production origins, that is, vertices, of the detected fragments were studied. Fragment trajectories were approximated by straight lines and a beam back-projection algorithm was built to reconstruct the vertices. The spatial distribution of the vertices was then used to determine plan relevant markers. Results The IMS technique was applied for a simulated CIRT case, a primary brain tumor. Four treatment plan monitoring markers were conclusively recovered: a depth dose distribution correlated profile, ion beam range, treatment target boundaries, and the beam spot position. Promising millimeter-scale (3-mm, ≤10% uncertainty) beam range and submillimeter (≤0.6-mm precision for shifts <3 cm) beam spot position verification accuracies were obtained for typical therapeutic energies between 150 and 290 MeV/u. Conclusions This work demonstrated a viable online monitoring technique for CIRT treatment delivery. The method's strong advantage is that it requires few signal inputs (position and timing), which can be simultaneously acquired with readily available technology. Future investigations will probe the technique's applicability to motion-sensitive organ sites and patient tissue heterogeneities. In-beam measurements with candidate detector-acquisition systems are ultimately essential to validate the IMS benchmark performance and subsequent deployment in the clinic.


Sign in / Sign up

Export Citation Format

Share Document