Validity of Urinary Catheter Specimen for Diagnosis of Urinary Tract Infection in the Elderly

1985 ◽  
Vol 145 (10) ◽  
pp. 1858 ◽  
Author(s):  
Dale Grahn
1986 ◽  
Vol 135 (4) ◽  
pp. 880-880
Author(s):  
D. Grahn ◽  
E.C. Norman ◽  
M.L. White ◽  
M. Cantrell ◽  
T.T. Yoshikawa

2006 ◽  
Vol 64 ◽  
pp. S108
Author(s):  
A. Brandenburg ◽  
M. Lingsma ◽  
S. Terpstra ◽  
H. Vd Mijle ◽  
A. Ott

2020 ◽  
Vol 40 (1) ◽  
pp. e12-e17
Author(s):  
Megan D. Snyder ◽  
Margaret A. Priestley ◽  
Michelle Weiss ◽  
Cindy L. Hoegg ◽  
Natalie Plachter ◽  
...  

Background Catheter-associated urinary tract infections are common health care–associated infections and have been associated with increased mortality, morbidity, length of stay, and cost. Prevention strategies are grouped into bundles focused on reducing unnecessary catheter use and promptly removing urinary catheters. Before intervention in the study institution, no urinary catheters were unnecessarily used and compliance with the catheter-associated urinary tract infection bundle was 84%. Objective To increase bundle compliance by using targeted rounds specifically focused on eliminating dependent loops in drainage tubing and ensuring appropriate catheter use to reduce the incidence of catheter-associated urinary tract infections. Methods A multidisciplinary team was formed to identify misperceptions, highlight best practices, and eliminate barriers to success over 1 year in a single pediatric intensive care unit. The team completed a quality improvement project of daily targeted rounding for patients with an indwelling urinary catheter. The goals were to assess appropriateness of catheterization, increase bundle compliance, and decrease catheter-associated urinary tract infection risk. Targeted rounds were conducted in addition to the medical team rounds. Results Bundle compliance supported by targeted rounding increased from 84% to 93% and helped reduce the overall catheter-associated urinary tract infection rate from 2.7 infections per 1000 catheter-days at baseline to 0. This change was sustained for 1 year. Conclusion Targeted rounding for pediatric patients with an indwelling urinary catheter is an effective and sustainable strategy to reduce catheter-associated urinary tract infections. The ease of implementation for this intervention lends itself to generalizability to other patient populations.


Author(s):  
Écila Campos Mota ◽  
Adriana Cristina Oliveira

ABSTRACT Objective: To identify factors related to the occurrence of urinary tract infection associated with urinary catheter use. Method: A longitudinal, retrospective cohort study carried out by analyzing the electronic medical records of patients admitted to an intensive care unit of a high-complexity hospital from July 2016 to June 2017. Demographic and clinical data were analyzed by descriptive and analytical analysis. Results: The incidence density of urinary tract infection related to urinary catheter use was 4.8 per 1000 catheters/day, the majority (80.6%) with no indication for catheter use, and there was no prescription for insertion and/or maintenance in 86.7%. The mean time between catheter insertion and infection diagnosis was 11.3 ± 6.3 days (6 to 28 days). Statistically significant factors (p < 0.001) related to urinary infection linked to catheter use were hospitalization time in the unit (16.7 ± 9 days), catheter permanence time (12.7 ± 6.9 days), and the use of antimicrobials in the intensive care unit (8.6 ± 6.3 days). Conclusion: The association of indication absence and the record of the need for maintenance possibly potentiated the occurrence of urinary tract infection associated to catheter use.


2020 ◽  
Vol 41 (3) ◽  
pp. 365-368
Author(s):  
Hong Chen ◽  
Joyce Wai Yan Lee ◽  
Kelvin Chung Ho Yu ◽  
Christina Ka Wai Chan ◽  
Andrew Tin Yau Wong ◽  
...  

AbstractWe conducted a survey of 16,914 patients to determine the point prevalence of healthcare-associated catheter-associated urinary tract infection (HA-CAUTI) and urinary catheter care in public hospitals in Hong Kong. Overall HA-CAUTI prevalence was 0.27%. Compliance was generally good, except for documenting the date of planned removal and securing the catheter properly.


Sign in / Sign up

Export Citation Format

Share Document