Myoelectric Prostheses and Targeted Reinnervation

Author(s):  
Levi Hargrove ◽  
Erik Scheme ◽  
Kevin Englehart
2012 ◽  
Vol 6 (1) ◽  
pp. 5-15 ◽  
Author(s):  
Michael R Dawson ◽  
Farbod Fahimi ◽  
Jason P Carey

The objective of above-elbow myoelectric prostheses is to reestablish the functionality of missing limbs and increase the quality of life of amputees. By using electromyography (EMG) electrodes attached to the surface of the skin, amputees are able to control motors in myoelectric prostheses by voluntarily contracting the muscles of their residual limb. This work describes the development of an inexpensive myoelectric training tool (MTT) designed to help upper limb amputees learn how to use myoelectric technology in advance of receiving their actual myoelectric prosthesis. The training tool consists of a physical and simulated robotic arm, signal acquisition hardware, controller software, and a graphical user interface. The MTT improves over earlier training systems by allowing a targeted muscle reinnervation (TMR) patient to control up to two degrees of freedom simultaneously. The training tool has also been designed to function as a research prototype for novel myoelectric controllers. A preliminary experiment was performed in order to evaluate the effectiveness of the MTT as a learning tool and to identify any issues with the system. Five able-bodied participants performed a motor-learning task using the EMG controlled robotic arm with the goal of moving five balls from one box to another as quickly as possible. The results indicate that the subjects improved their skill in myoelectric control over the course of the trials. A usability survey was administered to the subjects after their trials. Results from the survey showed that the shoulder degree of freedom was the most difficult to control.


Sensors ◽  
2019 ◽  
Vol 19 (23) ◽  
pp. 5209 ◽  
Author(s):  
Andrea Gonzalez-Rodriguez ◽  
Jose L. Ramon ◽  
Vicente Morell ◽  
Gabriel J. Garcia ◽  
Jorge Pomares ◽  
...  

The main goal of this study is to evaluate how to optimally select the best vibrotactile pattern to be used in a closed loop control of upper limb myoelectric prostheses as a feedback of the exerted force. To that end, we assessed both the selection of actuation patterns and the effects of the selection of frequency and amplitude parameters to discriminate between different feedback levels. A single vibrotactile actuator has been used to deliver the vibrations to subjects participating in the experiments. The results show no difference between pattern shapes in terms of feedback perception. Similarly, changes in amplitude level do not reflect significant improvement compared to changes in frequency. However, decreasing the number of feedback levels increases the accuracy of feedback perception and subject-specific variations are high for particular participants, showing that a fine-tuning of the parameters is necessary in a real-time application to upper limb prosthetics. In future works, the effects of training, location, and number of actuators will be assessed. This optimized selection will be tested in a real-time proportional myocontrol of a prosthetic hand.


2011 ◽  
Vol 35 (4) ◽  
pp. 395-401 ◽  
Author(s):  
Michael Kryger ◽  
Aimee E Schultz ◽  
Todd Kuiken

Background: Electromyography (EMG) pattern recognition offers the potential for improved control of multifunction myoelectric prostheses. However, it is unclear whether this technology can be successfully used by congenital amputees. Objective: The purpose of this investigation was to assess the ability of congenital transradial amputees to control a virtual multifunction prosthesis using EMG pattern recognition and compare their performance to that of acquired amputees from a previous study. Study Design: Preliminary cross-sectional study. Methods: Four congenital transradial amputees trained and tested a linear discriminant analysis (LDA) classifier with four wrist movements, five hand movements, and a no-movement class. Subjects then tested the classifier in real time using a virtual arm. Results: Performance metrics for the residual limb were poorer than those with the intact limb (classification accuracy: 52.1%±15.0% vs. 93.2%±15.8%; motion-completion rate: 49.0%±23.0% vs. 84.0%±9.4%; motion-completion time: 2.05±0.75 s vs. 1.13±0.05 s, respectively). On average, performance with the residual limb by congenital amputees was reduced compared to that reported for acquired transradial amputees. However, one subject performed similarly to acquired amputees. Conclusions: Pattern recognition control may be a viable option for some congenital amputees. Further study is warranted to determine success factors.


Sensors ◽  
2020 ◽  
Vol 20 (4) ◽  
pp. 1196 ◽  
Author(s):  
Seulah Lee ◽  
Babar Jamil ◽  
Sunhong Kim ◽  
Youngjin Choi

Myoelectric prostheses assist users to live their daily lives. However, the majority of users are primarily confined to forearm amputees because the surface electromyography (sEMG) that understands the motion intents should be acquired from a residual limb for control of the myoelectric prosthesis. This study proposes a novel fabric vest socket that includes embroidered electrodes suitable for a high-level upper amputee, especially for shoulder disarticulation. The fabric vest socket consists of rigid support and a fabric vest with embroidered electrodes. Several experiments were conducted to verify the practicality of the developed vest socket with embroidered electrodes. The sEMG signals were measured using commercial Ag/AgCl electrodes for a comparison to verify the performance of the embroidered electrodes in terms of signal amplitudes, the skin-electrode impedance, and signal-to-noise ratio (SNR). These results showed that the embroidered electrodes were as effective as the commercial electrodes. Then, posture classification was carried out by able-bodied subjects for the usability of the developed vest socket. The average classification accuracy for each subject reached 97.92%, and for all the subjects it was 93.2%. In other words, the fabric vest socket with the embroidered electrodes could measure sEMG signals with high accuracy. Therefore, it is expected that it can be readily worn by high-level amputees to control their myoelectric prostheses, as well as it is cost effective for fabrication as compared with the traditional socket.


2019 ◽  
Vol 4 (27) ◽  
pp. eaau8892 ◽  
Author(s):  
Edoardo D’Anna ◽  
Giacomo Valle ◽  
Alberto Mazzoni ◽  
Ivo Strauss ◽  
Francesco Iberite ◽  
...  

Current myoelectric prostheses allow transradial amputees to regain voluntary motor control of their artificial limb by exploiting residual muscle function in the forearm. However, the overreliance on visual cues resulting from a lack of sensory feedback is a common complaint. Recently, several groups have provided tactile feedback in upper limb amputees using implanted electrodes, surface nerve stimulation, or sensory substitution. These approaches have led to improved function and prosthesis embodiment. Nevertheless, the provided information remains limited to a subset of the rich sensory cues available to healthy individuals. More specifically, proprioception, the sense of limb position and movement, is predominantly absent from current systems. Here, we show that sensory substitution based on intraneural stimulation can deliver position feedback in real time and in conjunction with somatotopic tactile feedback. This approach allowed two transradial amputees to regain high and close-to-natural remapped proprioceptive acuity, with a median joint angle reproduction precision of 9.1° and a median threshold to detection of passive movements of 9.5°, which was comparable with results obtained in healthy participants. The simultaneous delivery of position information and somatotopic tactile feedback allowed both amputees to discriminate the size and compliance of four objects with high levels of performance (75.5%). These results demonstrate that tactile information delivered via somatotopic neural stimulation and position information delivered via sensory substitution can be exploited simultaneously and efficiently by transradial amputees. This study paves a way to more sophisticated bidirectional bionic limbs conveying richer, multimodal sensations.


2001 ◽  
Vol 21 (1-3) ◽  
pp. 221-225 ◽  
Author(s):  
C. Bonivento ◽  
A. Davalli ◽  
C. Fantuzzi

2017 ◽  
Vol 25 (10) ◽  
pp. 1832-1842 ◽  
Author(s):  
Radhika Menon ◽  
Gaetano Di Caterina ◽  
Heba Lakany ◽  
Lykourgos Petropoulakis ◽  
Bernard A. Conway ◽  
...  

1986 ◽  
Vol 10 (2) ◽  
pp. 79-82 ◽  
Author(s):  
W. F. Sauter ◽  
S. Naumann ◽  
M. Milner

The Muenster and Northwestern sockets have become universally prescribed for below-elbow amputees with myoelectric prostheses. The most attractive feature of these sockets is that they are self-suspending, thereby obviating the need for a harness. The sockets are designed to encompass the patient's whole elbow. Because of the intimate fit, heat build-up inside the socket is a problem. Patients with myoelectric prostheses are denied the benefit of a stump sock. Ventilation inside the socket is almost zero and excessive perspiration occurs. This leads to maceration and skin problems which negatively affect control, comfort and wearing time. This paper reports on a technique whereby the problem of no ventilation is overcome through the removal of the proximal-posterior quadrant of the socket.