High-melt-elasticity poly(ethylene terephthalate) produced by reactive extrusion with a multi-functional epoxide for foaming

2017 ◽  
Vol 135 (8) ◽  
pp. 45805 ◽  
Author(s):  
Zhaoping Yang ◽  
Chunling Xin ◽  
Waqas Mughal ◽  
Xiaogang Li ◽  
Yadong He
2001 ◽  
Vol 41 (8) ◽  
pp. 1299-1309 ◽  
Author(s):  
Quoc Tuan Nguyen ◽  
Sonia Japon ◽  
André Luciani ◽  
Yves Leterrier ◽  
Jan-Anders E. Månson

2006 ◽  
Vol 100 (5) ◽  
pp. 3646-3652 ◽  
Author(s):  
J. S. Forsythe ◽  
K. Cheah ◽  
D. R. Nisbet ◽  
R. K. Gupta ◽  
A. Lau ◽  
...  

2014 ◽  
Vol 34 (5) ◽  
pp. 431-439 ◽  
Author(s):  
Foued Zouai ◽  
Said Bouhelal ◽  
M. Esperanza Cagiao ◽  
Fatma Zohra Benabid ◽  
Djafer Benachour ◽  
...  

Abstract The success of processing compatible blends, based on poly(ethylene terephthalate) (PET)/poly(ethylene naphthalene 2,6-dicarboxylate) (PEN)/clay nanocomposites in one step by reactive melt extrusion is described. Untreated clay was first purified and functionalized “in situ” with a compound based on an organic peroxide/sulfur mixture and (tetramethylthiuram disulfide) as the activator for sulfur. The PET and PEN materials were first separately mixed in the molten state with functionalized clay. The PET/4 wt% clay and PEN/7.5 wt% clay compositions showed total exfoliation. These compositions, denoted nPET and nPEN, respectively, were used to prepare new nPET/nPEN nanoblends in the same mixing batch. The nPET/nPEN nanoblends were compared to neat PET/PEN blends. The blends and nanocomposites were characterized using various techniques. Microstructural and nanostructural properties were investigated. Fourier transform infrared spectroscopy (FTIR) results showed that the exfoliation of tetrahedral clay nanolayers is complete and the octahedral structure totally disappears. It was shown that total exfoliation, confirmed by wide angle X-ray scattering (WAXS) measurements, contributes to the enhancement of impact strength and tensile modulus. In addition, WAXS results indicated that all samples are amorphous. The differential scanning calorimetry (DSC) study indicated the occurrence of one glass transition temperature Tg, one crystallization temperature Tc and one melting temperature Tm for every composition. This was evidence that both PET/PEN and nPET/nPEN blends are compatible in the entire range of compositions. In addition, the nPET/nPEN blends showed lower Tc and higher Tm values than the corresponding neat PET/PEN blends. In conclusion, the results obtained indicate that nPET/nPEN blends are different from the pure ones in nanostructure and physical behavior.


Sign in / Sign up

Export Citation Format

Share Document