Novel methodology to perform incurred sample reanalysis on dried blood spot cards: Experimental data using darolutamide and filgotinib

2020 ◽  
Vol 34 (11) ◽  
Author(s):  
Vinay Kiran ◽  
Abhishek Dixit ◽  
Bhavesh Babulal Gabani ◽  
Nuggehally R. Srinivas ◽  
Ramesh Mullangi
Bioanalysis ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 393-407
Author(s):  
Ling He ◽  
Roohi Gajee ◽  
Raj Mangaraj ◽  
Michael P Waldron ◽  
Karen S Brown

Aim: Dried blood spot (DBS) is a sampling approach that offers several advantages over plasma and whole blood (WB) sampling, but several factors, such as hematocrit and temperature, can adversely affect quantitation. Methodology & results: In an open-label, three-way crossover study in healthy subjects, we explored the correlation between DBS, WB and plasma samples, and between DBS samples from finger-prick and venipuncture blood for measuring edoxaban and its metabolite M-4 using LC–MS/MS. The methods were validated comprehensively. The incurred sample reanalysis experiments demonstrated quantitation reproducibility in all three matrices. Overall, there was a good correlation (near perfect concordance for edoxaban) among plasma, WB and DBS measurements. M-4 concentrations in DBS and WB were lower than in plasma. Conclusion: These results indicate using DBS may be used as an alternative methodology to measure edoxaban pharmacokinetics.


Bioanalysis ◽  
2011 ◽  
Vol 3 (9) ◽  
pp. 1025-1030 ◽  
Author(s):  
Matthew Barfield ◽  
Sheelan Ahmad ◽  
Maria Busz

Cells ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 1532
Author(s):  
Jeffrey Yim ◽  
Olivia Yau ◽  
Darwin F. Yeung ◽  
Teresa S. M. Tsang

Fabry disease (FD) is an X-linked lysosomal storage disorder caused by mutations in the galactosidase A (GLA) gene that result in deficient galactosidase A enzyme and subsequent accumulation of glycosphingolipids throughout the body. The result is a multi-system disorder characterized by cutaneous, corneal, cardiac, renal, and neurological manifestations. Increased left ventricular wall thickness represents the predominant cardiac manifestation of FD. As the disease progresses, patients may develop arrhythmias, advanced conduction abnormalities, and heart failure. Cardiac biomarkers, point-of-care dried blood spot testing, and advanced imaging modalities including echocardiography with strain imaging and magnetic resonance imaging (MRI) with T1 mapping now allow us to detect Fabry cardiomyopathy much more effectively than in the past. While enzyme replacement therapy (ERT) has been the mainstay of treatment, several promising therapies are now in development, making early diagnosis of FD even more crucial. Ongoing initiatives involving artificial intelligence (AI)-empowered interpretation of echocardiographic images, point-of-care dried blood spot testing in the echocardiography laboratory, and widespread dissemination of point-of-care ultrasound devices to community practices to promote screening may lead to more timely diagnosis of FD. Fabry disease should no longer be considered a rare, untreatable disease, but one that can be effectively identified and treated at an early stage before the development of irreversible end-organ damage.


2021 ◽  
Vol 136 ◽  
pp. 104739
Author(s):  
Ranya Mulchandani ◽  
Ben Brown ◽  
Tim Brooks ◽  
Amanda Semper ◽  
Nicholas Machin ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Amelia E. Sancilio ◽  
Richard T. D’Aquila ◽  
Elizabeth M. McNally ◽  
Matthew P. Velez ◽  
Michael G. Ison ◽  
...  

AbstractThe spike protein of SARS-CoV-2 engages the human angiotensin-converting enzyme 2 (ACE2) receptor to enter host cells, and neutralizing antibodies are effective at blocking this interaction to prevent infection. Widespread application of this important marker of protective immunity is limited by logistical and technical challenges associated with live virus methods and venous blood collection. To address this gap, we validated an immunoassay-based method for quantifying neutralization of the spike-ACE2 interaction in a single drop of capillary whole blood, collected on filter paper as a dried blood spot (DBS) sample. Samples are eluted overnight and incubated in the presence of spike antigen and ACE2 in a 96-well solid phase plate. Competitive immunoassay with electrochemiluminescent label is used to quantify neutralizing activity. The following measures of assay performance were evaluated: dilution series of confirmed positive and negative samples, agreement with results from matched DBS-serum samples, analysis of results from DBS samples with known COVID-19 status, and precision (intra-assay percent coefficient of variation; %CV) and reliability (inter-assay; %CV). Dilution series produced the expected pattern of dose–response. Agreement between results from serum and DBS samples was high, with concordance correlation = 0.991. Analysis of three control samples across the measurement range indicated acceptable levels of precision and reliability. Median % surrogate neutralization was 46.9 for PCR confirmed convalescent COVID-19 samples and 0.1 for negative samples. Large-scale testing is important for quantifying neutralizing antibodies that can provide protection against COVID-19 in order to estimate the level of immunity in the general population. DBS provides a minimally-invasive, low cost alternative to venous blood collection, and this scalable immunoassay-based method for quantifying inhibition of the spike-ACE2 interaction can be used as a surrogate for virus-based assays to expand testing across a wide range of settings and populations.


2020 ◽  
Vol 58 (11) ◽  
pp. e275-e278
Author(s):  
Constantin Gatterer ◽  
Martina Gaggl ◽  
Gerald Mundigler ◽  
Paulus Rommer ◽  
Senta Graf ◽  
...  

2021 ◽  
Vol 15 (1) ◽  
pp. 433-437
Author(s):  
Alissa J. Roberts ◽  
Faisal Malik ◽  
Catherine Pihoker ◽  
Jane A. Dickerson

Sign in / Sign up

Export Citation Format

Share Document