SEISMIC PERFORMANCE OF STEEL MOMENT FRAME OFFICE BUILDINGS WITH RECTANGULAR CONCRETE-FILLED STEEL TUBE GRAVITY COLUMNS

ce/papers ◽  
2017 ◽  
Vol 1 (4) ◽  
pp. 554-563
Author(s):  
Nipun Pakwan ◽  
Johnn Judd
2012 ◽  
Vol 166-169 ◽  
pp. 2209-2215
Author(s):  
Zhi Xin Wang ◽  
Hai Tao Fan ◽  
Huang Juan Zhao

Finite element models of frames with steel-bracings and with concrete filled steel tube struts are built in ETABS. Seismic performance of these models is analyzed with base-shear method, superposition of modal responses method and time history method respectively. The results show that the steel-bracings or concrete filled steel tube struts are efficient to increase the story-stiffness, and the top displacement of the frame structure decreases significantly.


Author(s):  
C. E. Watkins ◽  
B. W. Toellner ◽  
K. Laknejadi ◽  
E. Abbas ◽  
M. R. Eatherton

2019 ◽  
Vol 23 (4) ◽  
pp. 794-809
Author(s):  
Yong Yang ◽  
Xing Du ◽  
Yunlong Yu ◽  
Yongpu Pan

The ultra-high-strength concrete-encased concrete-filled steel tube column consists of a concrete-filled steel tube core and a rectangle-shaped reinforced concrete encasement. This article presents the seismic performance analysis of ultra-high-strength concrete-encased concrete-filled steel tube columns subjected to cyclic loading. Based on the measured load-lateral displacement hysteresis curves of six ultra-high-strength concrete-encased concrete-filled steel tube columns and two conventional RC columns, the seismic behaviours, such as the ductility, energy dissipation, stiffness and load-bearing capacity, were analysed. The effects of the arrangement of the stirrups and the layout of the prestressed steel strips on the seismic performance of the composite columns were critically examined. The test results indicated that the ductility and energy dissipation performance of the ultra-high-strength concrete-encased concrete-filled steel tube columns were increased by 74.8% and 162.7%, respectively, compared with the conventional columns. The configuration of the prestressed steel strip increased the ductility of the composite column by 28.9%–63% and increased the energy consumption performance by 160.2%–263.3%. By reducing the stirrup spacing and using prestressed steel strips, the concrete-filled steel tube core columns could be effectively confined, leading to a great enhancement in ductility, energy dissipation, stiffness and load-bearing capacity.


Sign in / Sign up

Export Citation Format

Share Document