Quantitation of Metal Ions in Archaeological Glass by Abrasive Stripping Square-Wave Voltammetry Using Graphite/Polyester Composite Electrodes

2003 ◽  
Vol 15 (18) ◽  
pp. 1465-1475 ◽  
Author(s):  
A. Doménech-Carbó ◽  
M. T. Doménech-Carbó ◽  
L. Osete-Cortina ◽  
J. V. Gimeno-Adelantado ◽  
S. Sánchez-Ramos ◽  
...  
2003 ◽  
Vol 375 (8) ◽  
pp. 1169-1175 ◽  
Author(s):  
A. Doménech-Carbó ◽  
M. T. Doménech-Carbó ◽  
M. C. Saurí-Peris ◽  
J. V. Gimeno-Adelantado ◽  
F. Bosch-Reig

2014 ◽  
Vol 6 (13) ◽  
pp. 4775-4782 ◽  
Author(s):  
M. Ardelean ◽  
F. Manea ◽  
N. Vaszilcsin ◽  
R. Pode

Detection results obtained for sulphide detection in real water using a CNF electrode by square-wave voltammetry.


2019 ◽  
Vol 17 (1) ◽  
pp. 722-727 ◽  
Author(s):  
Veton Haziri ◽  
Avni Berisha ◽  
Fetah I. Podvorica

AbstractThe electrochemical grafting of the “in-situ” prepared diazopyridinium salt have permitted the attachment of pyridine moieties onto platinum and glassy carbon surfaces. The modification of the electrode surfaces is observed by a redox probe. The ability of the film for the complexation of copper (II) ions is demonstrated by square wave voltammetry. After 45 min accumulation of copper (II) ions onto the grafted electrode surfaces, the electrode signal obtained by square wave voltammetry measurement served to discriminate the adsorbed heavy metal ions. Such measurements showed that the grafted pyridine has the ability to display complexing behavior toward some heavy metal ions. DFT calculations support a strong binding of the pyridine moieties onto the Pt surface. The most favorable complexation mode of copper (II) ions as suggested from DFT is the bidentate complex. This strategy is vital in constructing a wide range of different electrochemical sensors.


2020 ◽  
Vol 16 (3) ◽  
pp. 341-348
Author(s):  
Surinya Traipop ◽  
Suchada Chuanuwatanakul ◽  
Orawon Chailapakul ◽  
Eakkasit Punrat

Background: Recently, Derris scandens, a Thai herbal medicine with anti-inflammatory activity, is widely used as beverage and supplementary food. When the traditional medicine is a choice for health therapy, the simple and reliable equipment is required to control the suitable consuming amount of the active component. Objective: To develop the electrochemical sensor for genistein determination in Derris scandens with high sensitivity and rapid operation. Methods: An in-house screen-printed electrochemical sensor consisting of a three-electrode system was developed for genistein determination. A silver/silver chloride (Ag/AgCl) reference electrode, a carbon counter electrode and a carbon working electrode were prepared on a 0.3-mm-thick plastic substrate by the screen-printing technique using conductive ink. The dimensions of each sensor were 2.5×1.0 cm. Only 50 µL of sample solution was required on this device for the determination of genistein concentration by rapid response square wave voltammetry. Results: The oxidation peak of genistein appeared with good response in acidic media at a peak potential of 0.6 V. Moreover, the signal was enhanced by modifying the conductive carbon ink with cobalt( II) phthalocyanine. Under the optimized conditions, the linear range was found to be 2.5-150 µM and the detection limit was 1.5 µM. Moreover, the small volume extraction was successfully developed without any further pre-concentration. This proposed method was applied to determine genistein in Derris scandens with satisfying results. Conclusion: The proposed method is promising as an alternative method for genistein determination with facile and fast analysis.


2009 ◽  
Vol 74 (10) ◽  
pp. 1489-1501 ◽  
Author(s):  
Marina Zelić ◽  
Milivoj Lovrić

Isopotential points in square-wave voltammetry are described for the first time. Model calculations and real measurements (performed with UO22+ and Eu3+ in perchlorate and bromide solutions, respectively) indicate that such an intersection could be observed when backward components of the net response, resulting from an increase in frequency or reactant concentration, are presented together. The electrode reaction should be fully reversible because quasireversible or slower electron transfer processes give the isopoints only at increasing reactant concentrations but not at increasing square-wave frequencies. The effect could be used as an additional diagnostic criterion for recognition of reversible electrode reactions where products remain dissolved in the electrolyte solution.


Sign in / Sign up

Export Citation Format

Share Document