Electroreduction of Nitroaromatic Compounds at Electrochemically Reduced Graphene Oxide Supported Bimetallic Ag@Pd Nanorods Modified Electrodes

2016 ◽  
Vol 28 (9) ◽  
pp. 1984-1991 ◽  
Author(s):  
S. E. Jeena ◽  
P. Gnanaprakasam ◽  
T. Selvaraju
Biomolecules ◽  
2019 ◽  
Vol 9 (5) ◽  
pp. 176 ◽  
Author(s):  
Quanguo He ◽  
Yaling Tian ◽  
Yiyong Wu ◽  
Jun Liu ◽  
Guangli Li ◽  
...  

In this paper, a nanocomposite of cuprous oxide and electrochemically reduced graphene oxide (Cu2O–ERGO) was prepared by a simple and low-cost method; hereby, a new method for the electrochemical determination of tryptophan (Trp) by this composite modified glassy carbon electrode (GCE) is proposed. The prepared materials and modified electrodes were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and cyclic voltammetry (CV). The results showed that Cu2O–ERGO/GCE had good electrocatalytic activity for Trp. The effects of supporting electrolyte, scanning rate, accumulation potential, and accumulation time on the determination of Trp were studied. Under the optimum experimental conditions, Trp was quantitatively analyzed by square-wave voltammetry (SWV). The oxidation peak current of Trp had a good linear relationship with its concentration in the range of 0.02–20 μM, and the detection limit was 0.01 μM (S/N = 3). In addition, the modified electrode has high sensitivity, good repeatability, and long-term stability. Finally, the proposed method has been successfully applied in the determination of Trp concentration in practical samples.


Sensors ◽  
2020 ◽  
Vol 20 (23) ◽  
pp. 6799
Author(s):  
Matei D. Raicopol ◽  
Andreea M. Pandele ◽  
Constanţa Dascălu ◽  
Eugeniu Vasile ◽  
Anamaria Hanganu ◽  
...  

A new thiosemicarbazone ligand was immobilized through a Cu(I)-catalyzed click reaction on the surface of glassy carbon (GC) and electrochemically reduced graphene oxide (GC-ERGO) electrodes grafted with phenylethynyl groups. Using the accumulation at open circuit followed by anodic stripping voltammetry, the modified electrodes showed a significant selectivity and sensibility for Hg(II) ions. A detection limit of 7 nM was achieved with the GC modified electrodes. Remarkably, GC-ERGO modified electrodes showed a significantly improved detection limit (0.8 nM), sensitivity, and linear range, which we attribute to an increased number of surface binding sites and better electron transfer properties. Both GC and GC-ERGO modified electrodes proved their applicability for the analysis of real water samples.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Gen Liu ◽  
Wei Ma ◽  
Yan Luo ◽  
Deng-ming Sun ◽  
Shuang Shao

Poly(methylene blue) and electrochemically reduced graphene oxide composite film modified electrode (PMB-ERGO/GCE) was successfully fabricated by electropolymerization and was used for simultaneous determination of uric acid (UA) and xanthine (Xa). Based on the excellent electrocatalytic activity of PMB-ERGO/GCE, the electrochemical behaviors of UA and Xa were studied by cyclic voltammetry (CV) and square wave voltammetry (SWV). Two anodic sensitive peaks at 0.630 V (versus Ag/AgCl) for UA and 1.006 V (versus Ag/AgCl) for Xa were given by CV in pH 3.0 phosphate buffer. The calibration curves for UA and Xa were obtained in the range of 8.00 × 10−8~4.00 × 10−4 M and 1.00 × 10−7~4.00 × 10−4 M, respectively, by SWV. The detection limits for UA and Xa were3.00×10-8 M and5.00×10-8 M, respectively. Finally, the proposed method was applied to simultaneously determine UA and Xa in human urine with good selectivity and high sensitivity.


Sign in / Sign up

Export Citation Format

Share Document