scholarly journals Peri‐left bundle branch pacing after atrioventricular node ablation and failed his bundle pacing in atrial fibrillation

2020 ◽  
Vol 36 (1) ◽  
pp. 203-205 ◽  
Author(s):  
Alexander Edo Tondas ◽  
Raymond Pranata ◽  
Han Hongwei
2021 ◽  
Vol 30 (4) ◽  
pp. 634-638
Author(s):  
Catalin Pestrea ◽  
Alexandra Gherghina ◽  
Irina Pintilie ◽  
Florin Ortan

Atrial fibrillation (AF) is a serious cause of morbidity and mortality in the general population, with an increasing prevalence with the improvement in diagnosis. The best current treatment approach is catheter ablation (mainly isolation of the pulmonary veins), but this is ineffective in permanent atrial fi brillation. Rate control is frequently mandatory in these patients and the most effective technique is atrioventricular node ablation. But, since this procedure renders the patient pacemaker dependent, one should be very cautious with the pacing mode selected for long-term pacing. We present the case of a 45 year-old male with permanent atrial fi brillation and drug-refractory rapid ventricular rate and tachycardia-induced cardiomyopathy, who underwent catheter ablation of the atrioventricular node and permanent selective His bundle pacing. Following the procedure, the patient went from a rapid, irregular rhythm to a controlled, regular rhythm without a change in QRS morphology. The follow-up after three months showed near complete recovery of the left ventricle and the disappearance of heart failure symptoms.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Ciesielski ◽  
A Slawuta ◽  
A Zabek ◽  
K Boczar ◽  
B Malecka ◽  
...  

Abstract   A single-chamber ICD is a standard method for primary SCD prophylaxis. In patients with chronic atrial fibrillation it does not contribute to the regularization of heart rate, which is crucial for proper treatment. Moreover, to avoid the deleterious effect of right ventricular pacing only minority of the patients with single chamber ICD get the appropriate, recommended dose of beta-blockers. The aim of our study was to assess the efficacy of direct His-bundle pacing in a population of patients with congestive heart failure and chronic atrial fibrillation using upgrade from single chamber to dual-chamber ICD and atrial channel to perform the His-bundle pacing Methods The study population included 39 patients (37 men, 2 women) aged 67.2±9.3 years, with CHF and chronic AF implanted primarily with single chamber ICD with established pharmacotherapy and stable clinical status. Results The echocardiography measurements at baseline and during follow-up were presented in the table: During short period (3–6 months) of follow-up the mean values of EF and LV dimensions significantly improved. This was also accompanied by functional status improvement. Conclusions His-bundle-based pacing in CHF-chronic AF patients contributes to significant echocardiographic and clinical improvement. Standard single-chamber ICD implantation in CHF-chronic AF patients yields only SCD prevention without influence on remodeling process. The physiological pacing contributes to better pharmacotherapy. Funding Acknowledgement Type of funding source: None


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Slawuta ◽  
K Boczar ◽  
A Zabek ◽  
A Ciesielski ◽  
J Hiczkiewicz ◽  
...  

Abstract The heart rate regularization is crucial for proper treatment of patients with atrial fibrillation and congestive heart failure. The standard resynchronization can be applied, but in patients with narrow QRS this procedure is of no use. The aim of our study is to assess the efficacy of direct His-bundle pacing in patients with congestive heart failure and chronic atrial fibrillation using dual chamber ICD implanted for prevention of sudden cardiac death. Methods The study population included 78 patients with CHF and chronic AF: group A - 56 pts treated with direct His-bundle pacing using atrial port of dual chamber ICD and group B - 22 patients implanted with single chamber ICD as recommended by the guidelines. The patients in group B constituting clinical controls were derived from the Heart Failure Outpatients Clinic with established clinical status and pharmacotherapy. Results The demographic data, clinical characteristics and echocardiography measurements at baseline and during follow-up were presented in the table: Table 1 Group A Group B P value Age (years) 69.7±6.9 66.7±11.3 n.s. Sex (% of male sex) 84.0 86.4 n.s. Ventricular pacing (%) – 46.3±31.2 – His-bundle pacing (%) 81.7±9.2 – – pre post pre post pre vs. post LVEDD (mm) 66.9±4.9 59.9±4.7 64.8±8.0 64.7±8.1 <0.01 n.s. EF (%) 29.6±3.8 43.6±5.9 28.1±6.1 28.8±7.3 <0.01 n.s. NYHA class 2.7±0.6 1.4±0.6 2.5±0.6 2.0±0.2 <0.05 n.s. B-blocker dose (metoprolol equivalent dose) 104.6±41.6 214.3±82.6 78.3±56.6 103.1±49.2 <0.001 <0.05 During 12-months of follow-up the mean values of NYHA functional class, EF and LV dimensions did not change in group B but significantly improved in group A. The physiological His-bundle based pacing enabled optimal beta-blocker dosing. The studied groups had no tachyarrhythmia at baseline so the presumable atrial fibrillation-related harm depends on the rhythm irregularity. Conclusions His-bundle-based pacing in CHF-chronic AF patients contributes to significant echocardiographic and clinical improvement. Standard single-chamber ICD implantation in CHF-chronic AF patients yields only SCD prevention without influence on remodeling process. The CHF-patients with narrow QRS and chronic AF benefit from substantially higher beta-blockade which can be instituted in His-bundle pacing group.


1982 ◽  
Vol 243 (5) ◽  
pp. H754-H760 ◽  
Author(s):  
T. Mazgalev ◽  
L. S. Dreifus ◽  
J. Bianchi ◽  
E. L. Michelson

Atrial fibrillation was induced in 15 superfused rabbit atrial-atrioventricular nodal preparations in which surface bipolar electrograms were recorded simultaneously from the crista terminalis, interatrial septum, and His bundle along with microelectrode action potentials from cells in the atrionodal (AN), nodal (N), and nodal-His (NH) regions of the atrioventricular node. Effective engagement of the atrioventricular node with propagation to the His bundle was critically dependent on the relative timing of activation at the crista terminalis and interatrial septal input regions of the atrioventricular node. Conduction through the AN and N regions appeared dependent on the relative timing of activation wave fronts emerging from the two input regions. Asynchronous engagement of AN and N regions resulted in both distortion of action potentials and concealed conduction, with delayed conduction and block to the NH region and His bundle. Successful engagement of the NH region always produced a 1:1 NH-to-His bundle relationship. It is concluded that during atrial fibrillation 1) activation of the AN region occurs as a result of the variable interaction of inputs from the crista terminalis and interatrial septum; 2) predictably, effective synchronous engagement of the AN and consequently the N region is responsible for conduction to the NH and His bundle regions; 3) conversely, asynchronous activation inputs from the crista terminalis and interatrial septum result in fragmented, asynchronous as well as concealed conduction within the AN and N regions with block in the atrioventricular node and variable conduction to the His bundle.


Sign in / Sign up

Export Citation Format

Share Document