Revealing the Two‐Dimensional Surface Diffusion Mechanism for Zinc Dendrite Formation on Zinc Anode

Small ◽  
2021 ◽  
pp. 2104148
Author(s):  
Zefang Yang ◽  
Chaonan Lv ◽  
Wenbin Li ◽  
Tingqing Wu ◽  
Qi Zhang ◽  
...  
1991 ◽  
Vol 06 (39) ◽  
pp. 3591-3600 ◽  
Author(s):  
HIROSI OOGURI ◽  
NAOKI SASAKURA

It is shown that, in the three-dimensional lattice gravity defined by Ponzano and Regge, the space of physical states is isomorphic to the space of gauge-invariant functions on the moduli space of flat SU(2) connections over a two-dimensional surface, which gives physical states in the ISO(3) Chern–Simons gauge theory. To prove this, we employ the q-analogue of this model defined by Turaev and Viro as a regularization to sum over states. A recent work by Turaev suggests that the q-analogue model itself may be related to an Euclidean gravity with a cosmological constant proportional to 1/k2, where q=e2πi/(k+2).


In this paper we discuss two-dimensional surface source and implant problems for a substitutional-interstitial diffusion model. We present asymptotic solutions in the limit of the surface concentration of impurity (or peak concentration of the implant) being far greater than the equilibrium vacancy concentration. Using leading order composite solutions we plot contours of constant impurity concentration. Some of these contours differ markedly from those of the corresponding linear problem, having the ‘bird’s beak’ shape which is frequently observed in experiments. We also discuss a two-dimensional surface source problem for a va­cancy model.


1999 ◽  
Vol 32 (26) ◽  
pp. 9007-9012 ◽  
Author(s):  
Jakob Heier ◽  
Easan Sivaniah ◽  
Edward J. Kramer

2005 ◽  
Vol 295-296 ◽  
pp. 477-482
Author(s):  
K.W. Wang ◽  
Z.J. Cai ◽  
Li Jiang Zeng

A two-dimensional surface profile imaging technique based on heterodyne interferometer is proposed. A piezo translator vibrated grating is used to generate a heterodyne signal. A high speed CCD camera is used to extract the interference signal using a five step method. The uncertainty in the displacement measurement is approximately 0.035 µm within a measurement range of 1.7 µm, confirming the two dimensional heterodyne interferometer is valid for measuring the surface profile. The method is also available for low coherence heterodyne interferometer due to the optical frequency shifts caused by the vibration of grating independent on the wavelength.


1987 ◽  
Vol 188 (3) ◽  
pp. 589-598 ◽  
Author(s):  
Gary A. Attard ◽  
David A. King

Sign in / Sign up

Export Citation Format

Share Document