Development of Real-time Dose Assessment System for Korean Nuclear Power Plant

Author(s):  
Kuk Ki Kim ◽  
Kun Jai Lee ◽  
Won jong Park
2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Hongyun Xie ◽  
Haixia Gu ◽  
Chao Lu ◽  
Jialin Ping

Real-time Simulation (RTS) has long been used in the nuclear power industry for operator training and engineering purposes. And, online simulation (OLS) is based on RTS and with connection to the plant information system to acquire the measurement data in real time for calibrating the simulation models and following plant operation, for the purpose of analyzing plant events and providing indicative signs of malfunctioning. OLS has been applied in certain industries to improve safety and efficiency. However, it is new to the nuclear power industry. A research project was initiated to implement OLS to assist operators in certain critical nuclear power plant (NPP) operations to avoid faulty conditions. OLS models were developed to simulate the reactor core physics and reactor/steam generator thermal hydraulics in real time, with boundary conditions acquired from plant information system, synchronized in real time. The OLS models then were running in parallel with recorded plant events to validate the models, and the results are presented.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Kwame Gyamfi ◽  
Sylvester Attakorah Birikorang ◽  
Emmanuel Ampomah-Amoako ◽  
John Justice Fletcher

Abstract Atmospheric dispersion modeling and radiation dose calculation have been performed for a generic 1000 MW water-water energy reactor (VVER-1000) assuming a hypothetical loss of coolant accident (LOCA). Atmospheric dispersion code, International Radiological Assessment System (InterRAS), was employed to estimate the radiological consequences of a severe accident at a proposed nuclear power plant (NPP) site. The total effective dose equivalent (TEDE) and the ground deposition were calculated for various atmospheric stability classes, A to F, with the site-specific averaged meteorological conditions. From the analysis, 3.7×10−1 Sv was estimated as the maximum TEDE corresponding to a downwind distance of 0.1 km within the dominating atmospheric stability class (class A) of the proposed site. The intervention distance for evacuation (50 mSv) and sheltering (10 mSv) were estimated for different stability classes at different distances. The intervention area for evacuation ended at 0.5 km and that for sheltering at 1.5 km. The results from the study show that designated area for public occupancy will not be affected since the estimated doses were below the annual regulatory limits of 1 mSv.


2001 ◽  
Vol 135 (2) ◽  
pp. 123-130 ◽  
Author(s):  
Arne Hornaes ◽  
John Einar Hulsund ◽  
János Végh ◽  
Csaba Major ◽  
Csaba Horváth ◽  
...  

Author(s):  
B.K. Hajek ◽  
D.W. Miller ◽  
R. Bhatnagar ◽  
J.E. Stasenko ◽  
W.F. Punch ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document