Solar Concentrators: State of the Art

Author(s):  
Tetyana Baydyk ◽  
Ernst Kussul ◽  
Donald C. Wunsch II
2011 ◽  
Vol 95 (8) ◽  
pp. 2087-2094 ◽  
Author(s):  
Jana Bomm ◽  
Andreas Büchtemann ◽  
Amanda J. Chatten ◽  
Rahul Bose ◽  
Daniel J. Farrell ◽  
...  

2020 ◽  
Vol 11 (2) ◽  
Author(s):  
Debrayan Bravo Hidalgo ◽  
Alexander Báez Hernández

The objective of this contribution is to provide a state-of-the-art on research in solar thermal electricity systems. This objective is achieved using Scopus, and the softwears “Publish or Perish” and “VOSviewer”. The results of the research show the behavior of scientific productivity in this area. As well as the most productive thematic areas. Nations that lead the research in the generation of electric power on a large scale, using solar thermal energy. Network of scientific collaboration among nations, referring to the research of electricity generation through solar thermal energy. Correlation network among the most productive authors, in this subject within the Scopus directory. Most cited articles by each of the main journals that disseminate this theme. Conceptual bases of the generation of electricity with solar thermal energy. Properties of thermal energy storage technologies (TES) in power plants with parabolic solar concentrators or solar concentration towers. Current technologies and trends. Technological trends. Trends in the global energy market.


1991 ◽  
Vol 113 (3) ◽  
pp. 180-187 ◽  
Author(s):  
Thomas R. Mancini

The state-of-the-art of parabolic dish solar concentrators is the faceted, glass-metal dish. The mass production costs of glass-metal dishes may be high because they do not incorporate the innovations of design and materials developed over the last eight years. Therefore, Sandia National Laboratories has undertaken to develop two stretched-membrane parabolic dish concentrators for the Department of Energy’s Solar Thermal Program. These solar concentrators are being designed for integration with an advanced solar receiver and a Stirling engine/generator in a 25-kWe power production unit. The first dish, which builds on the successful design of the stretched-membrane heliostats, is to be a low risk, near-term commercial solar concentrator. This solar concentrator comprises 12 large, 3.6-m diameter, stretched-membrane facets that are formed into parabolic shapes either with a large vacuum or by performing the thin membranes plastically. The focal length-to-diameter ratios (f/Ds) for the facets are about 3.0, relatively large for a dish but much lower than heliostats where they typically range from 50 to 100. Two contractors are currently fabricating facets for this dish, and a third contractor is designing the facet support structure and pedestal for the dish. The second stretched-membrane concentrator is a single-element monolithic dish with an f/D of 0.6. The dish is shaped into a parabola by plastically yielding the membrane using a combination of uniform and nonuniform loading. Initial measurements of the dish indicate that it has a slope error of 2.6 milliradians (one standard deviation) relative to a perfect parabola. In this paper, the designs of the two stretched-membrane dishes are analyzed using the computer code CIRCE to model the optical performance of the concentrators and a thermal model, which includes conduction, convection, and radiation heat transfer, to calculate the thermal losses from the cavity solar receivers. The solar collector efficiency, defined as the product of the optical efficiency of the collector and the thermal efficiency of the receiver, is optimized for comparing the performance of several solar concentrator configurations. Ten facet arrangements for the faceted stretched-membrane dish and the single-element stretched-membrane dish are modeled and their performances compared with that of a state-of-the-art glass-metal dish. Last, the initial designs of these two stretched-membrane dishes are described along with the results of preliminary performance measurements on their respective optical elements.


Author(s):  
T. A. Welton

Various authors have emphasized the spatial information resident in an electron micrograph taken with adequately coherent radiation. In view of the completion of at least one such instrument, this opportunity is taken to summarize the state of the art of processing such micrographs. We use the usual symbols for the aberration coefficients, and supplement these with £ and 6 for the transverse coherence length and the fractional energy spread respectively. He also assume a weak, biologically interesting sample, with principal interest lying in the molecular skeleton remaining after obvious hydrogen loss and other radiation damage has occurred.


Author(s):  
Carl E. Henderson

Over the past few years it has become apparent in our multi-user facility that the computer system and software supplied in 1985 with our CAMECA CAMEBAX-MICRO electron microprobe analyzer has the greatest potential for improvement and updating of any component of the instrument. While the standard CAMECA software running on a DEC PDP-11/23+ computer under the RSX-11M operating system can perform almost any task required of the instrument, the commands are not always intuitive and can be difficult to remember for the casual user (of which our laboratory has many). Given the widespread and growing use of other microcomputers (such as PC’s and Macintoshes) by users of the microprobe, the PDP has become the “oddball” and has also fallen behind the state-of-the-art in terms of processing speed and disk storage capabilities. Upgrade paths within products available from DEC are considered to be too expensive for the benefits received. After using a Macintosh for other tasks in the laboratory, such as instrument use and billing records, word processing, and graphics display, its unique and “friendly” user interface suggested an easier-to-use system for computer control of the electron microprobe automation. Specifically a Macintosh IIx was chosen for its capacity for third-party add-on cards used in instrument control.


Nanoscale ◽  
2020 ◽  
Vol 12 (33) ◽  
pp. 17265-17271
Author(s):  
Seong Kyung Nam ◽  
Kiwon Kim ◽  
Ji-Hwan Kang ◽  
Jun Hyuk Moon

Luminescent solar concentrator-photovoltaic systems (LSC-PV) harvest solar light by using transparent photoluminescent plates, which is expected to be particularly useful for building-integrated PV applications.


2010 ◽  
Vol 20 (1) ◽  
pp. 9-13 ◽  
Author(s):  
Glenn Tellis ◽  
Lori Cimino ◽  
Jennifer Alberti

Abstract The purpose of this article is to provide clinical supervisors with information pertaining to state-of-the-art clinic observation technology. We use a novel video-capture technology, the Landro Play Analyzer, to supervise clinical sessions as well as to train students to improve their clinical skills. We can observe four clinical sessions simultaneously from a central observation center. In addition, speech samples can be analyzed in real-time; saved on a CD, DVD, or flash/jump drive; viewed in slow motion; paused; and analyzed with Microsoft Excel. Procedures for applying the technology for clinical training and supervision will be discussed.


Sign in / Sign up

Export Citation Format

Share Document