Observations of Damage to Uto City Hall Suffered in the 2016 Kumamoto Earthquake

Author(s):  
K. Fujii ◽  
T. Yoshida ◽  
T. Nishimura ◽  
T. Furuta
Buildings ◽  
2019 ◽  
Vol 9 (6) ◽  
pp. 140 ◽  
Author(s):  
Kenji Fujii

The seismic capacity of the main Uto City Hall building, which was severely damaged by the 2016 Kumamoto Earthquake, was evaluated by the proposed pushover-based procedure. In this procedure, the seismic capacity index of the building is defined as the maximum scaling factor of the seismic input, for which the local responses do not exceed their limit values. From the pushover analysis result, the displacement limit of the equivalent single-degree-of-freedom model was determined. Then, the seismic capacity index was evaluated using an equivalent linearization technique. The evaluated index was re-evaluated by considering the bidirectional excitation. The pushover analysis result revealed that the torsional response is significant in the nonlinear behavior of this building. The evaluated seismic capacity implied that some structural damages, including the yielding of the beam-column joint, may have occurred during the first earthquake on 14 April 2016.


Buildings ◽  
2019 ◽  
Vol 9 (11) ◽  
pp. 234
Author(s):  
Kenji Fujii

It is very unfortunate that there are some errors in the nonlinear analysis program used for this published article [...]


2020 ◽  
Vol 72 (1) ◽  
Author(s):  
Yasuhira Aoyagi ◽  
Haruo Kimura ◽  
Kazuo Mizoguchi

Abstract The earthquake rupture termination mechanism and size of the ruptured area are crucial parameters for earthquake magnitude estimations and seismic hazard assessments. The 2016 Mw 7.0 Kumamoto Earthquake, central Kyushu, Japan, ruptured a 34-km-long area along previously recognized active faults, eastern part of the Futagawa fault zone and northernmost part of the Hinagu fault zone. Many researchers have suggested that a magma chamber under Aso Volcano terminated the eastward rupture. However, the termination mechanism of the southward rupture has remained unclear. Here, we conduct a local seismic tomographic inversion using a dense temporary seismic network to detail the seismic velocity structure around the southern termination of the rupture. The compressional-wave velocity (Vp) results and compressional- to shear-wave velocity (Vp/Vs) structure indicate several E–W- and ENE–WSW-trending zonal anomalies in the upper to middle crust. These zonal anomalies may reflect regional geological structures that follow the same trends as the Oita–Kumamoto Tectonic Line and Usuki–Yatsushiro Tectonic Line. While the 2016 Kumamoto Earthquake rupture mainly propagated through a low-Vp/Vs area (1.62–1.74) along the Hinagu fault zone, the southern termination of the earthquake at the focal depth of the mainshock is adjacent to a 3-km-diameter high-Vp/Vs body. There is a rapid 5-km step in the depth of the seismogenic layer across the E–W-trending velocity boundary between the low- and high-Vp/Vs areas that corresponds well with the Rokkoku Tectonic Line; this geological boundary is the likely cause of the dislocation of the seismogenic layer because it is intruded by serpentinite veins. A possible factor in the southern rupture termination of the 2016 Kumamoto Earthquake is the existence of a high-Vp/Vs body in the direction of southern rupture propagation. The provided details of this inhomogeneous barrier, which are inferred from the seismic velocity structures, may improve future seismic hazard assessments for a complex fault system composed of multiple segments.


2021 ◽  
Vol 73 (1) ◽  
Author(s):  
Kodai Nakagomi ◽  
Toshiko Terakawa ◽  
Satoshi Matsumoto ◽  
Shinichiro Horikawa

An amendment to this paper has been published and can be accessed via the original article.


Sign in / Sign up

Export Citation Format

Share Document