Destruction of Unresectable Brain Tumors: Simulation of Thermal Spread and Tissue Damage During MRI-Guided Laser Ablation

Author(s):  
Gesine Hentschel ◽  
Johannes Johansson ◽  
Christina Winkler ◽  
Birgit Glasmacher ◽  
Karin Wårdell
2019 ◽  
Vol 1 (Supplement_2) ◽  
pp. ii12-ii12
Author(s):  
Michiharu Yoshida ◽  
Kazuo Maruyama ◽  
Yasutaka Kato ◽  
Rachmilevitch Itay ◽  
Syuji Suzuki ◽  
...  

Abstract OBJECTIVE In neuro-oncology, it is believed that one major obstacle to effective chemotherapy is the high vascularity and heterogenous permeability of brain tumors. Focused ultrasound (FUS) exposure with the microbubbles has been shown to transiently open the blood-brain barrier (BBB) without depositing thermal energy, and thus may enhance the delivery of various therapeutic drugs into brain tumors. The aim of this study was to evaluate the BBB opening using 220-kHz transcranial MRI-guided FUS (TcMRgFUS) device and microbubbles in mouse and rat. METHODS The experiments were performed with the 220-kHz ExAblate Neuro TcMRgFUS system (InSightec) and novel lipid bubbles (LB, Teikyo Univ.). Normal mouse and rat brains were irradiated with TcMRgFUS (output power, 5W; duration of irradiation, 30 s; duty cycle 100%) following intravenous injection of 6x107 LB per mouse and rat, respectively. On irradiation, target temperature rise & cavitation signal were monitored by MR thermometry and cavitation receiver, respectively. Immediately after irradiation, BBB opening and complications were detected based on T1, T2, T2*, and Gadolinium (Gd) enhanced T1-weighted images. RESULTS The maximum temperature of brain tissue was under 42 C. There were no risky-cavitation signals causing hemorrhage. The FUS-LB exposure induced successful BBB opening effect in both mouse and rat, confirmed by Gd enhancement in the target region, lateral ventricles, and sulcus. In addition, there were no complications such as edema, coagulation, and hemorrhage. CONCLUSIONS Although there remain many conditions to be optimized, BBB opening using a 220-kHz TcMRgFUS device and LB can offer a non-invasive and feasible drug delivery for brain malignancies.


Author(s):  
Sławomir Blamek ◽  
Dawid Larysz ◽  
Kornelia Ficek ◽  
Maria Sokół ◽  
Leszek Miszczyk ◽  
...  

2004 ◽  
Vol 1268 ◽  
pp. 1284 ◽  
Author(s):  
Takashi Inomata ◽  
Yoshihiro Muragaki ◽  
Hiroshi Iseki ◽  
Takeyoshi Dohi ◽  
Nobuhiko Hata

1998 ◽  
Vol 8 (1) ◽  
pp. 121-127 ◽  
Author(s):  
Hans-Joachim Schwarzmaier ◽  
Ilya V. Yaroslavsky ◽  
Anna N. Yaroslavsky ◽  
Volkhard Fiedler ◽  
Frank Ulrich ◽  
...  

2014 ◽  
Author(s):  
Jeremy Cepek ◽  
Uri Lindner ◽  
Sangeet Ghai ◽  
Sean R. H. Davidson ◽  
John Trachtenberg ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document